Publications

Export 163 results:
Sort by: Author Title [ Type  (Desc)] Year
Thesis
Comportamento às acções cíclicas de pilares de betão armado reforçados com materiais compósitos, Chastre Rodrigues, C. , Faculdade de Ciências e Tecnologia, Universidade NOVA de Lisboa, Lisboa, (2005) Abstract

This thesis deals with the analysis of the behaviour of retrofitting reinforced concrete circular columns with FRP materials which were subjected either to axial cyclic compression or axial compression and alternated cyclic horizontal loads. The choice of this topic derived from the need to investigate the behaviour of the strengthening of reinforced concrete columns to seismic actions, especially with new materials such as carbon and glass fibres or polymeric mortars. Another reason for such choice is linked to the strong seismicity of the Portuguese territory.
It has been verified that confined concrete columns with FRP jackets have their resistance and ductility highly increased as these considerably reduce the columns transversal deformation, thus preventing the buckling of longitudinal reinforcement. There has been an increasing use of FRP composites in the strengthening of structures, mainly with GFRP (Glass Fibre Reinforced Plastics) or CFRP (Carbon Fibre Reinforced Plastics). This is due to their attractive characteristics such as high resistance to corrosion, lowratio for weight/strength, moldability, easy application and the fact that there is no need of support structures.
Forty-five experimental tests were carried out, dealing with retrofitting reinforced concrete columns with axial monotonic or cyclic compression reinforced with FRP composites. The column height of 750 mm was maintained in order to evaluate the influence of several parameters in its behaviour: the column geometry (change in its diameter), the type of column (plain or reinforced concrete), transversal reinforcement ratio of concrete columns, the type of external confinement with FRP (C or GFRP), the number of FRP layers and the type of axial loading (monotonic or cyclic).
Twelve additional experimental tests were conducted in order to analyse the behaviour of reinforced concrete columns jacketed with FRP composites and subjected to axial cyclic compression and alternated cyclic horizontal loads. The columns’ dimension was maintained (1500 mm height by 250 mm diameter) and the models were subjected to a series of cyclic and alternated loadings. This enabled the study of the various parameters’ influence in their behaviour such as the type of FRP confinement, the number of FRP layers, the level of axial loading, the jacket’s height or the strengthening of the plastic hinge by replacing the cover concrete with polymeric mortar.
Based on the numerical models presented and experimental analysis carried out, models were proposed and developed to simulate the behaviour of columns jacketed with FRP composites.

Comportamento da Ligação Aço-Resina-Betão em Elementos Estruturais, Chastre Rodrigues, C. , Departamento de Engenharia Civil, Instituto Superior Técnico, 1993, Volume MSc, Lisboa, (1993) Abstract1993_-_msc-_ist_-_carlos_chastre_-_comportamento_da_ligacao_aco-resina-betao_em_elementos_estruturais.pdf

The present work studies the behaviour of bonded steel plates to reinforced concrete elements, which can be used in the strengthening of concrete structural elements. Metallic expansion bolts can be added.The objective of this dissertation is to investigate the behaviour to monotonic actions and particularly to cyclic loading of steel-epoxy-concrete connection with expansion bolts. This cyclic action is of particular interest due to the strong seismicity of the Portuguese territory.The research is mainly based in experimental analysis. The caracterization of the materials was carried out. Six models of the steel-epoxy connection were tested with monotonic loading. Twenty six models of steel-epoxy-concrete bond were submitted either to monotonic or to cyclic actions.Besides the type of action, other parameters were studied in the steel-epoxy-concrete connection models.These were the bond geometry area, the type of concrete, the type of epoxy and connection - with or without metallic expansion bolts.A parametric study with a numerical model of finite elements, as well as a global analysis of the experimental tests of the steel-epoxy-concrete connection was carried out.

Report
Miscellaneous
2017 International Conference on Building Materials and Materials Engineering - ICBMM 2017, Chastre, Carlos, and Mendonça Paulo , September 21-23,, Volume 264, Lyon, France, p.159, (2017) Abstract
n/a
2nd International Conference on Building Materials and Materials Engineering - ICBMM 2018, Chastre, Carlos, and Mendonça Paulo , September 26-28,, Volume 278, Lisbon, Portugal, p.168, (2019) Abstract

n/a

Cáceres-Florencia, patrimonio vivo: Ensayos técnico-arquitectónicos, Salcedo Hernández, José Carlos, Fortea Luna Manuel, Lauria Antonio, Rovero Luisa, Tonietti Ugo, Chastre Carlos, González Jiménez Luis, Matas Casco Miguel, and Saumell Lladó Juan , Suplementos de Investigación en Construcciones Arquitectónicas , Volume 3, Cáceres, p.156, (2017) Abstract
n/a
Displacement measurements with ARPS in T-beams load tests, Almeida, G., Melicio F., Chastre C., and Fonseca J. , Volume 349 AICT, p.286-293, (2011) Abstract

The measurement of deformations, displacements, strain fields and surface defects in many material tests in Civil Engineering is a very important issue. However, these measurements require complex and expensive equipment and the calibration process is difficult and time consuming. Image processing could be a major improvement, because a simple camera makes the data acquisition and the analysis of the entire area of the material under study without requiring any other equipment like in the traditional method. Digital image correlation (DIC) is a method that examines consecutive images, taken during the deformation period, and detects the movements based on a mathematical correlation algorithm. In this paper, block-matching algorithms are used in order to compare the results from image processing and the data obtained with linear voltage displacement transducer (LVDT) sensors during laboratorial load tests of T-beams. © 2011 IFIP International Federation for Information Processing.

Magazine Article
Construção, inovação e pré-fabricação em betão, Chastre, Carlos , Construção Magazine, Novembro/Dezembr, Volume 88, Number Novembro/Dezembro, p.59-61, (2018) AbstractWebsite

Num mundo em constante mutação, as próximas décadas na indústria da construção serão, certamente, muito influenciadas pelos desenvolvimentos nas áreas dos materiais, da informática, do processamento de dados, da industrialização e da automação. A pré-fabricação em betão é, hoje em dia, uma forma de construção segura, económica, durável, sustentável e arquitetonicamente versátil. Trata-se de uma forma industrializada de construção com diversas vantagens, pois permite incorporar, de forma mais rápida, económica, adequada e sustentável, a inovação em materiais, sistemas e processos.A produção em fábrica significa processos de fabrico racionais e eficientes, controlo de qualidade, trabalhadores qualificados, repetição de tarefas, e menor custo de mão-de-obra por m² devido à automação do processo de produção. Deste modo, a industrialização da construção transfere a maioria dos trabalhos do local da obra para a fábrica. As distâncias máximas de transporte por camião deverão variar entre 150 e 350 km, dependendo do tipo de produtos e da rede viária, podendo, em algumas situações, o transporte ser feito por comboio ou por navio, caso em que as distâncias máximas podem aumentar até 2.000 km [3]. Dependendo da acessibilidade do local e da capacidade do sistema de elevação, o processo de montagem em obra deverá ser discutido no início do projeto. Em termos de sustentabilidade, a indústria de pré-fabricação a nível europeu está apostada na redução de 45% de matérias-primas e de 30% do consumo energético. Várias fábricas já reciclam o betão não utilizado e em breve funcionarão num sistema de produção fechado, em que todo os resíduos serão processados e reutilizados [3]. No futuro, o betão pré-fabricado será por excelência o veículo preferido para a introdução dos agregados reciclados na indústria de construção, dado o controlo de qualidade a que é sujeito. O controlo de qualidade na pré-fabricação começa no estudo e preparação do projeto, e continua com a produção das peças de betão e com a entrega e montagem a tempo e horas. O controlo de qualidade durante o processo de fabrico é baseado em quatro pilares fundamentais: pessoas, instalações e equipamentos, matérias-primas e processos de execução, e controlo de qualidade da execução. A maioria das empresas de pré-fabricação possui a certificação ISO-9000.As caraterísticas das estruturas pré-fabricadas permitem adaptá-las, na maioria das situações, às exigências do arquiteto ou do dono de obra, não existindo antagonismo entre a elegância arquitetónica e o aumento da eficiência estrutural (Figura 1). Atualmente, industrialização já não significa um número elevado de peças de betão idênticas, pelo contrário, um processo de produção eficiente pode ser combinado com a mão-de-obra qualificada existente na fábrica, o que permite desenvolver um projeto de arquitetura moderno e sem custos adicionais. A utilização de vãos grandes, sem restrições a possíveis subdivisões com paredes divisórias, permite a flexibilidade do espaço, adaptando-o às necessidades do utilizador, tal como é exigido nos edifícios de escritórios. Quer no passado quer atualmente, a maioria dos edifícios tradicionais são concebidos para uma utilização específica, sem atender a futuras alterações de uso e consequentes remodelações ou demolições. Para obviar a esta desvantagem, a solução passa por fazer uma distinção clara entre a parte estrutural dos edifícios e os acabamentos, possibilitando, desta forma, futuras remodelações sem demolição da estrutura do edifício. Hoje as estruturas pré-fabricadas em betão já são concebidas de acordo com este conceito, dada a capacidade existente nas vigas e pavimentos para vencerem grandes vãos, o que facilita a criação de grandes espaços abertos no interior do edifício. As caraterísticas das lajes alveoladas permitem que as redes de instalações sejam aí incorporadas, e, além disso, pode-se tirar partido da massa térmica do betão da laje para armazenar energia térmica. Os elementos pré-fabricados de betão possibilitam uma ampla variedade de acabamentos, desde superfícies cuidadosamente moldadas até ao betão à vista. Deste modo, o arquiteto dispõe de painéis de fachada, vigas e pilares com formas especiais e com acabamentos de alta qualidade (Figura 2). Além disso, o projetista pode inspecionar e aceitar as peças pré-fabricadas antes de serem transportadas e fixadas no local. Os painéis em betão arquitetónico oferecem uma ampla gama de acabamentos, numa grande variedade de cores e texturas, por exemplo em calcário ou granito, ou através de acabamentos mais complexos em tijoleiras cerâmicas ou em alvenaria de pedra natural ou artificial que seriam extremamente caros se aplicados in situ pelos métodos tradicionais. A pré-fabricação, comparativamente à construção in situ, tem um maior potencial para apresentar estruturas mais económicas, melhor desempenho estrutural e maior durabilidade por causa da otimização dos materiais utilizados, a qual é obtida tendo por base as matérias-primas, os equipamentos de fabricação utilizados e os procedimentos de trabalho cuidadosamente estudados. Os trabalhos de pré-fabricação utilizam equipamento de dosagem e mistura controlados por computador, bem como aditivos e adjuvantes na mistura para obter os desempenhos mecânicos pretendidos. A betonagem e a vibração do betão são realizadas com condições de trabalho e equipamentos ideais. O teor de água pode ser reduzido ao mínimo e a cura também ocorre em circunstâncias controladas. A classe do betão utilizada pode ser adequada às exigências de cada tipo de elemento, de forma a otimizar o uso de materiais mais caros. O betão pré-fabricado oferece uma liberdade de ação considerável para a melhoria da eficiência estrutural, permitindo produtos mais esbeltos e um uso otimizado dos materiais. Maiores vãos e menores alturas úteis podem ser obtidos através da utilização do pré-esforço em vigas e pavimentos. O pré-esforço é frequentemente utilizado na pré-fabricação devido às pistas de pré-tensão existentes e aos fios de pré-esforço serem ancorados por aderência. O betão pré-fabricado pré-esforçado proporciona todas as vantagens construtivas do betão pré-esforçado, mas também a economia na fabricação, devido à reduzida mão-de-obra e à ausência de dispositivos de ancoragem dispendiosos. Outra vantagem do betão pré-fabricado é a melhoria da durabilidade. Contudo, os melhores benefícios são obtidos para os elementos verticais, especialmente para os pilares, onde a capacidade de carga pode aumentar entre 100% a 150% quando a resistência do betão passa de 30 para 90 MPa [3]. As estruturas pré-fabricadas em betão armado e pré-esforçado apresentam, normalmente, uma resistência ao fogo de 60 a 120 minutos ou mais [3]. Atualmente os betões de alto desempenho já são utilizados em algumas estruturas pré-fabricadas e no futuro próximo, em especial em zonas com alguma agressividade ambiental, o betão pré-fabricado verá as armaduras de aço substituídas por armaduras de matérias compósitos. O desempenho das estruturas pré-fabricadas tem sido analisado face a sismos de diferentes intensidades, tendo a maioria registado um bom desempenho, enquanto outras, em especial as mais antigas, mostraram algumas deficiências. A investigação a nível internacional dai resultante, tem sido particularmente útil para melhorar a pormenorização das ligações das estruturas pré-fabricadas, bem como para avaliar a ductilidade geral destas estruturas (que mostrou ser bastante comparável à das estruturas construídas in situ), ajudando assim a definir fatores de comportamento adequados [4].Na última década a Comissão 6 da pré-fabricação, da Federação Internacional do Betão (fib) publicou um conjunto de relatórios técnicos [1-5] sobre edifícios pré-fabricados, dedicados em especial às ligações estruturais [1], às ações acidentais [2], aos painéis sandwich [5], ao projeto de estruturas pré-fabricadas em geral [3] e ao projeto de edifícios em zonas sísmicas [4], onde estes temas são abordados em detalhe e que podem ser uma mais-valia para todos os que se queiram dedicar a esta temática.

CREatE, um sistema inovador de reforço estrutural utilizando compósitos de CFRP, Chastre, Carlos , Construção Magazine, Novembro/Dezembr, Volume 80, Issue Julho/Agosto, Number Novembro/Dezembro, p.46-47, (2017) AbstractWebsite

A procura de soluções de reforço mais duráveis e de fácil aplicação tem levado à utilização crescente dos compósitos de FRP (Fiber Reinforced Polymer) no reforço de estruturas, dada a sua resistência à corrosão, o baixo quociente peso/resistência mecânica, a sua moldabilidade, a facilidade de aplicação e a eliminação de estruturas de suporte. No reforço estrutural de vigas de betão armado com compósitos de FRP, são tradicionalmente utilizados dois tipos de técnicas: os sistemas em que o laminado é colado pelo exterior (EBR - Externally-Bonded Reinforcement) ou aqueles em que o laminado é inserido em rasgos previamente abertos na camada de recobrimento (NSM - Near Surface Mounted). No entanto, as técnicas utilizadas, o comportamento elástico-linear destes materiais e as roturas tendencialmente frágeis das soluções condicionam a sua utilização em estruturas onde se pretende alguma ductilidade. A técnica de reforço NSM apresenta algumas vantagens em relação à técnica EBR, nomeadamente ao nível da proteção das armaduras [1]. Além disso, o desempenho em termos de ductilidade do sistema e resistência final excede a técnica EBR. Contudo, diversos ensaios experimentais [2-5] têm mostrado que roturas prematuras [6] da ligação na interface ou o destacamento do betão na zona do recobrimento entre a face inferior das armaduras ordinárias e as armaduras de reforço podem limitar significativamente a eficiência do sistema, originando modos de rotura frágeis e desperdício de material por falta de otimização da quantidade de material aplicado [1]. A fim de evitar a rotura prematura das soluções de reforço tradicionais (EBR e NSM), foi concebido na Universidade NOVA um sistema inovador de reforço intitulado CREatE (Continuous Reinforcement Embedded at Ends). O sistema CREatE foi idealizado para ser utilizado com diversos materiais [1, 5] e diferentes elementos estruturais, tais como vigas [1, 3], pilares [7], pavimentos [8], lajes ou paredes, em que é necessário aumentar a sua capacidade resistente através de armaduras pós-instaladas. A solução de reforço CREatE caracteriza-se pela utilização de armaduras contínuas embutidas nas extremidades do elemento estrutural sem o uso de dispositivos mecânicos para as fixar. Antes da ancoragem da armadura de reforço no interior do elemento, é necessário utilizar uma curva de transição suave para al terar a forma da armadura de reforço e evitar a concentração de tensões no la minado de CFRP (Carbon Fiber Reinforced Polymer) ou na interface e, desta forma, ter um fluxo gradual de tensões transmitidas à zona de ancoragem existente no interior do elemento. Para validar a solução CREatE foi realizada uma campanha de ensaios à flexão de vigas de betão armado com seção em T, uma altura total de 0,3m, um vão livre de 3,0m e reforçadas com laminados de CFRP recorrendo a diferentes técnicas (EBR, NSM e CREatE). As vigas foram testadas à flexão em 4 pontos, tendo-se obtido resultados promissores (Figura 1), com a eliminação na técnica CREatE dos modos de rotura prematuros. Na Figura 2 é possível observar uma viga ensaiada com a técnica CREatE em que se detetam aberturas de fendas significativas sem que se verifique qualquer rotura prematura do sistema. Além da eliminação dos modos de rotura prematuros, os ensaios comprovam que a técnica CREatE permite o incremento da ductilidade (Figura 1) e a exploração total da capacidade do CFRP [1, 3, 5].

Ductilidade e resistência no reforço de pilares de betão armado sem aumento de secção, Chastre, Carlos , Construção Magazine, Março/Abril de 2, Volume 84, Number Março/Abril, p.48-49, (2018) AbstractWebsite

O aumento da resistência e/ou da ductilidade é um objetivo primordial quando se procede ao reforço de pilares. Um método bastante eficaz de aumentar a ductilidade, particularmente em regiões sísmicas, é através do encamisamento com coletes de FRP, uma vez que esta técnica permite uma diminuição da deformação transversal do pilar e a limitação da encurvadura das armaduras longitudinais, aumentando consequentemente a ductilidade do mesmo. Diversos ensaios experimentais permitiram detetar que os incrementos são maiores em secções circulares do que em secções quadradas ou retangulares [1, 2]. A atenuação deste efeito é obtida através do arredondamento dos cantos nos pilares de secção retangular. Contudo, o encamisamento com coletes de FRP, por si só, não aumenta significativamente a resistência do pilar à flexão composta. Para que isso aconteça e se mantenha um nível elevado de ductilidade, é necessário adicionar armaduras longitudinais à armadura do pilar e posteriormente proceder ao encamisamento com colete de FRP. Uma forma muito eficiente de o conseguir, mantendo a seção transversal do pilar, é utilizando o sistema CREatE (Continuous Reinforcement Embedded at Ends) desenvolvido na Universidade NOVA e já anteriormente apresentado nesta coluna, na edição de Junho/Agosto de 2017 [3], para o caso do reforço de vigas. O sistema CREatE foi idealizado para ser utilizado com diversos materiais e diferentes elementos estruturais [4-7], em que é necessário aumentar a sua capacidade resistente através de armaduras pós-instaladas, caracterizando-se pela utilização de armaduras contínuas embutidas nas extremidades do elemento estrutural sem o uso de dispositivos mecânicos para as fixar. Antes da ancoragem da armadura de reforço no interior do elemento, é necessário utilizar uma curva de transição suave para alterar a forma da armadura de reforço e evitar a ocorrência de concentrações de tensões na armadura ou na interface [4, 7, 8]. Este conceito foi aplicado no reforço de pilares realizado no âmbito da tese de doutoramento de Faustino Marques [9].Na Figura 1 é possível observar dois pilares de seção retangular (20x40cm2) encamisados com coletes de 3 camadas de CFRP (200gr/m2) em que foi utilizado o sistema CREatE com armaduras pós-instaladas de aço inox (2x20x5mm2) ou de laminados de CFRP (2x(10+20)×1.4 mm2/face) para reforço longitudinal [7, 8]. Na Figura 2 pode observar-se os resultados dos ensaios experimentais de um conjunto de pilares de seção retangulares sujeitos a esforço axial e a ações horizontais cíclicas. O pilar P11 é o de referência pois, não foi reforçado, enquanto os pilares P12, P15 e P16 foram encamisados com coletes de 3 camadas de CFRP e nos pilares P15 e P16 foi utilizado adicionalmente o sistema CREatE com armaduras pós-instaladas de aço inox (P15) ou de laminados de CFRP (P16) para reforço longitudinal [7]. Na Figura 3 mostra-se a envolvente dos diagramas Força-Deslocamento dos ensaios dos diferentes pilares de seção retangular (P11; P12; P15 e P16), sendo possível de constatar um excelente desempenho não só em termos de ductilidade (incremento de 67%) como de resistência (incrementos entre 29% e 43%, para drifts entre 2 e 4%) dos pilares reforçados com o sistema CREatE relativamente ao pilar de referência não reforçado.

Precast concrete wind tower structures. Historic development, current development and future potential, Lúcio, Válter, and Chastre Carlos , CPI - Concrete Plant International, 3, June 2014, Number 3, p.110-115, (2014) Abstractcpi_03-2014_p144-149.pdfWebsite

The wind energy production is a growing industry and the energy produced is renewable and environmentally cleaner than most of the energy production systems. The supports of the wind energy generators may be built with precast concrete elements. The precast solutions for these structures are competitive in comparison to other structural systems. The evolution of the technology for wind energy production shows a clear need for larger wind turbines and longer blades and, consequently, taller towers. The experience also shows that precast concrete solutions increase their competitiveness as the tower height increases. Offshore wind farms have some advantages in relation to onshore ones, which explains recent investments in this area. Also in this case, the durability of concrete in the sea when compared to steel, gives advantages to precast concrete in relation to other structural solutions. This paper shows the evolution of the supports of the wind energy generators and the advantages of the use of precast concrete towers.

Journal Article
Analysis of load–strain models for RC square columns confined with CFRP, Faustino, Pedro, and Chastre Carlos , Composites Part B: Engineering, June 2015, Volume 74, p.23-41, (2015) AbstractWebsite

This article presents the comparison between 6 theoretical models of axially confined concrete columns with the experimental results of 7 tested columns of different authors. This study analysed the accuracy of 6 different confinement models for square columns taking into account the results of experimental tests on 7 RC columns confined with CFRP sheets with different dimensions and carried out by different authors. The profile of curves, the peak/failure values, the stress–strain and axial–to–lateral relations were studied to conclude which models show the best correlation with the experimental test results. Quantification of this deviation was carried out for key parameters. Some models predicted peak values with reasonable accuracy – Manfredi & Realfonzo, Campione & Miraglia, Lam & Teng, Pellegrino & Modena – although for the whole load–strain behaviour only the model of Faustino, Chastre & Paula seemed to be reasonably accurate in most cases.

Analysis of the debonding process of CFRP-to-timber interfaces, Biscaia, Hugo C., Cruz David, and Chastre Carlos , Construction and Building Materials, 6/15/, Volume 113, p.96-112, (2016) AbstractWebsite

The use of Fiber Reinforced Polymers (FRP) in the strengthening of timber structures is quite recent and few studies have discussed the debonding between these materials. The analysis of the Mode II debonding process between FRP composites and timber elements may be of great importance because this mode is predominant in the case, for instance, of the bending of beams. Knowing the appropriate bond-slip model to use on the estimation of the performance of FRP-to-timber interfaces is greatly relevant. Under such circumstances, a detailed knowledge of all the states that CFRP-to-timber interfaces are subjected to is important as well. The current work gives answers to these aspects proposing an analytical solution based on a tri-linear bond-slip model that is capable of describing precisely the full-range debonding behavior of FRP-to-timber interfaces. Thus, the purpose of this study is to contribute to existing knowledge with an analytical solution capable of describing the full-range debonding process between a FRP composite and a substrate. The analytical solutions herein proposed are also compared with the results obtained from several experiments based on single-lap shear tests. Comparisons at different load levels and different bonded lengths are presented. The slips, strains in the CFRP composite and bond stress distributions within the bonded interface are emphasized in the text. The complete load-slip response of CFRP-to-timber interface is also analyzed. Each state of the debonding process is described and each one is identified in the load-slip curve.

Analytical model with uncoupled adhesion laws for the bond failure prediction of curved FRP-concrete joints subjected to temperature, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Theoretical and Applied Fracture Mechanics, Volume 89, p.63-78, (2017) Abstract

The strengthening of structures such as columns, beams, arches or slabs with Fibre Reinforced Polymers (FRP) has been the focus of several studies. However, the studies dedicated to the FRP debonding phenomenon of curved bonded joints affected by elevated temperatures are surprisingly limited and no studies on this topic are known, at present, to use nonlinear analytical or numerical approaches. Still, the available studies found in the literature are unanimous in affirming that the debonding phenomenon on such curved interfaces demands the interaction between Fracture Modes I and II. The present work aims to develop an analytical solution capable of simulating the debonding process of curved CFRP-toconcrete interfaces with a constant radius subjected to mechanical and/or thermal loads. Some examples are presented in which the influence of the radius of the interface and the temperature level is analysed. The analytical solution proposed here is based on adhesion laws in which, in the case ofMode II, an exponential bond vs. relative displacement law with temperature dependency is assumed, whereas the Mode I adhesive law is based on a linear with fragile rupture law with the same temperature dependency as Mode II.

Application of fuzzy inference system for determining weathering degree of some monument stones in Iran, Heidari, Mojtaba, Chastre Carlos, Torabi-Kaveh Mehdi, Ludovico-Marques Marco, and Mohseni Hassan , Journal of Cultural Heritage, Volume 25, p.41-55, (2017) Abstract

This paper presents a comparative evaluation of efficiencies of different accelerated ageing tests (freezethaw, thermal shock, salt crystallization, dissolution and wetting-drying) and fuzzy inference system in predicting weathering degrees of some monument stones from three historical sites (Anahita Temple, Anobanini reliefs and Eshkaft-e Salman reliefs, Iran). The combined effects of natural weathering processes (heating and cooling, wetting and drying, and freezing and thawing) and climatic information were used for assessing the natural weathering degrees. Finally, the natural weathering degrees were multiplied by time effect coefficients to obtain more realistic natural weathering degrees of the monuments. The predicted natural weathering degrees for Anahita Temple, Anobanini reliefs and Eshkaft-e Salman reliefs are 56%, 61%, and 47%, respectively. These predicted values reasonably support the weathering degrees defined by progressive decay indices (calculated equal to 2.77, 3.42 and 2.66 for Anahita Temple, Anobanini reliefs and Eshkaft-e Salman reliefs, respectively), which means the fuzzy model potentially could accurately predict the weathering of stones.

Assessing the behaviour of RC beams subject to significant gravity loads under cyclic loads, Gião, Rita, Lúcio Válter, and Chastre Carlos , Engineering Structures, 2//, Volume 59, Number 2, p.512-521, (2014) AbstractWebsite

Gravity loads can affect a reinforced concrete structure’s response to seismic actions, however, traditional procedures for testing the beam behaviour do not take this effect into consideration. An experimental campaign was carried out in order to assess the influence of the gravity load on RC beam connection to the column subjected to cyclic loading. The experiments included the imposition of a conventional quasi-static test protocol based on the imposition of a reverse cyclic displacement history and of an alternative cyclic test procedure starting from the gravity load effects. The test results are presented, compared and analysed in this paper. The imposition of a cyclic test procedure that included the gravity loads effects on the RC beam ends reproduces the demands on the beams’ critical zones more realistically than the traditional procedure. The consideration of the vertical load effects in the test procedure led to an accumulation of negative (hogging) deformation. This phenomenon is sustained with the behaviour of a portal frame system under cyclic loads subject to a significant level of the vertical load, leading to the formation of unidirectional plastic hinges. In addition, the hysteretic behaviour of the RC beam ends tested was simulated numerically using the nonlinear structural analysis software – OpenSees. The beam–column model simulates the global element behaviour very well, as there is a reasonable approximation to the hysteretic loops obtained experimentally.

Avaliação dos Portais de Pedra Arenítica da Igreja de São Leonardo Utilizando Testes Não Destrutivos, Chastre, Carlos, and Ludovico-Marques Marco , Mecânica Experimental, Volume 28, p.47-54, (2017) AbstractWebsite

Neste artigo é apresentado um resumo das intervenções de conservação realizadas no século passado e dos estudos e testes não destrutivos realizados na última década na Igreja de São Leonardo na Atouguia da Baleia. Em seguida mostra-se o padrão de degradação que ocorre nos portais de arenito da igreja e é analisada a evolução da alveolização que ocorreu nos portais de arenito ao longo dos últimos sessenta a setenta anos. No final, a inspeção visual dos portais de arenito é comparada com um levantamento realizado através de varrimento por laser 3D.

Bond characteristics of CFRP-to-steel joints, Yang, Yongming, Biscaia Hugo, Chastre Carlos, and Silva Manuel A. G. , Journal of Constructional Steel Research, Volume 138, p.401-419, (2017) Abstract

Carbon Fiber Reinforced Polymer (CFRP) composites have a large potential for strengthening and retrofitting steel parts but due to their premature debonding from steel, further data and research are still required for wider application in such situations. In the present paper, the bond characteristics of CFRP-to-steel joints in pull-pull loaded conditions were studied. Monotonic loading of the double strap joints with different bond lengths was applied and the failure modes and interfacial bond-slip curves were obtained. A tri-linear bondslip model is proposed and it was derived from the experimental data. A closed-form solution approach is also proposed based on the tri-linear bond-slip model. The strength of the CFRP-to-steel interface, the distribution of the relative displacements between bonded materials, the strains developed in the CFRP laminate and the bond stresses along the interface are reported and the closed-form solution is compared with the experimental results. Two cases are selected for presentation: (i) one with the bond length greater than the effective bond length; and, inversely, (ii) one with bond length which is shorter than the effective bond length. The results predicted by the closed-form solutions are shown to be accurate enough when compared to the experiments.

Bond durability of CFRP laminates-to-steel joints subjected to freeze-thaw, Yang, Yongming, Silva Manuel A. G., Biscaia Hugo, and Chastre Carlos , Composite Structures, 2019/03/15/, Volume 212, p.243-258, (2019) AbstractWebsite

The degradation mechanisms of bonded joints between CFRP laminates and steel substrates under severe environmental conditions require more durability data and studies to increase the database and better understand their causes. Studies on bond properties of double-strap CFRP-to-steel bonded joints with two different composite materials as well as adhesive coupons subjected to freeze-thaw cycles for 10,000 h were conducted to reduce that gap. In addition, the equivalent to the number of thermal cycles and their slips induced in the CFRP laminates was replicated by an equivalent (mechanical) loading-unloading history condition imposed by a static tensile machine. The mechanical properties of the adhesive coupons and the strength capacity of the bonded joints were only slightly changed by the artificial aging. It was confirmed that the interfacial bond strength between CFRP and adhesive is critically related to the maximum shear stress and failure mode. The interfacial bond strength between adhesive and steel degraded with the aging. However, the equivalent thermal cyclic bond stress caused no detectable damage on the bond because only the interfacial elastic regime was actually mobilized, which confirmed that pure thermal cycles aging, per se, at the level imposed, have a low impact on the degradation of CFRP-to-steel bonded joints.

Bond-slip model for FRP-to-concrete bonded joints under external compression, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composites Part B: Engineering, 10//, Volume 80, p.246-259, (2015) AbstractWebsite

The influence of compressive stresses exerted on FRP-concrete joints created by external strengthening of structural members on the performance of the system requires better understanding especially when mechanical devices are used to anchor the externally bonded reinforcement (EBR). The numerical modelling of those systems is a tool that permits insight into the performance of the corresponding interfaces and was used in the present study, essentially directed to analyse the effectiveness of EBR systems under compressive stresses normal to the composite surface applied to GFRP-to-concrete interfaces. The compressive stresses imposed on the GFRP-to-concrete interface model the effect produced by a mechanical anchorage system applied to the EBR system. An experimental program is described on which double-lap shear tests were performed that created normal stresses externally applied on the GFRP plates. A corresponding bond-slip model is proposed and the results of its introduction in the numerical analysis based in an available 3D finite element code are displayed, showing satisfactory agreement with the experimental data. The results also showed that lateral compressive stresses tend to increase the maximum bond stress of the interface and also originate a residual bond stress which has significant influence on the interface strength. Also, the strength of the interface increases with the increase of the bonded length which have consequences on the definition of the effective bond length.

Caracterização Experimental e Modelação Numérica da Ligação GFRP/BETÃO, Biscaia, H. E. C., Silva M. G., and Chastre C. , Mecânica Experimental, Number 16, p.9-18, (2009) Abstractbiscaia2009sich.pdfWebsite

Analisa-se e caracteriza-se por via experimental a ligação entre elementos de betão armado e materiais compósitos, nomeadamente com base nas fibras de vidro. Fabricaram-se vigas de betão armado que foram exteriormente reforçadas com GFRP. Os resultados obtidos experimentalmente foram comparados com os resultados conseguidos por intermédio de modelação computacional, recorrendo-se ao programa de cálculo ATENA 2D. Para melhor modelação de elementos de interface, foram realizados ensaios de corte tendo-se obtido valores que permitiram caracterizar a lei de rotura de Mohr-Coulomb. Os parâmetros estudados foram a evolução das forças máximas absorvidas pelo reforço; as tensões de aderência máximas; a distribuição das tensões de aderência.

Carbonation service life modelling of RC structures for concrete with Portland and blended cements, Marques, Pedro Faustino, Chastre Carlos, and Nunes Ângela , Cement and Concrete Composites, Volume 37, p.171-184, (2013) Abstractmarques_chastre_et_al._2013.pdfWebsite

The presented work aims at studying the modelling of long term performance of concrete compositions with different proportions of clinker as regards the diffusion of CO2 in concrete – carbonation. The replacing constituents of clinker that will be part of the binder in each concrete composition are limestone filler and low calcium fly ash (FA). The used percentage of FA by weight of binder was of 50%. Concrete compositions were made following standard prescribed requirements to attain service lives of 50 and 100 years as regards concrete performance against reinforcing steel corrosion. Test results of compressive strength and carbonation depth are reported at different curing ages of 28, 90, 180 and 365 days. Carbonation results were used for the implementation of modelling equations in order to estimate the design service life regarding reinforcing steel corrosion. Two performance-based methods were used: safety factor method and probabilistic method, and their results compared with the traditional prescriptive approach. At the age of 28 days the composition with OPC is the only one that reaches the target periods of 50 or 100 years. For the probabilistic method, different curing age results were analysed. For the tested results at 90, 180 and 365 days of age the reliability of some of the compositions with blended cements is within the minimum required, although still far from the higher performance of concrete with OPC.

CFRP-to-steel bonded joints subjected to cyclic loading: An experimental study, Yang, Yongming, Silva Manuel A. G., Biscaia Hugo, and Chastre Carlos , Composites Part B: Engineering, 1 August 2018, Volume 146, p.28–41, (2018) AbstractWebsite

Pseudo-cyclic and cyclic loading were applied to CFRP-to-steel bonded joints built with two different CFRP laminates. In this paper, the strength capacity and bond-slip curves are presented and compared. The modes of failure are also described and associated with the types of material used, and the observed performances are correlated. The analysis of the results showed a threshold value for loading and amplitude level, below which the cyclic loading caused no detectable damage. For cycles above that limit, the region of the joints around the loaded end presented degradation reflected on the bond-slip stiffness and on the increase of residual deformation. It was found that the normalized dissipated energies either obtained from the bond-slip relationship or from the load-slip response had the same trend. The experimental data allowed also to establish a relationship between the damage developed within the interface and the normalized slip. A preliminary estimate of fatigue limit based on those data is suggested.

Characterisation of unidirectional fibre reinforced grout as a strengthening material for RC structures, Gião, Rita, Lúcio Valter, and Chastre Carlos , Construction and Building Materials, Volume 137, p.272-287, (2017) Abstract

The main goal of the present research work is to characterise a unidirectional fibre reinforced grout (UFRG), developed as an alternative material to strengthen RC structures using small thickness jacketing. A high performance cementitious grout reinforced with continuous and unidirectional non-woven steel fibre mat has been developed for this purpose. It was expected that the optimization of the percentage and alignment of the steel fibres would yield a more efficient fibre grout. In fact, the composite should attain higher tensile strength with continuous fibres since the fibre embedment length is enough to prevent fibre pull-out. An experimental programme was carried out to characterise the UFRG’s mechanical properties. Compressive tests were conducted on small thickness tubular specimens to enable the determination of the compressive strength and the static modulus of elasticity. The tensile strength was obtained from splitting tests performed on cubic specimens (DIN 1048-5). Semi-empirical equations, based on the experimental results, are proposed to estimate UFRG’s modulus of elasticity, compressive strength and tensile strength. Two strengthening solutions for RC structures using small thickness CFRP jacketing are presented.

Compression behaviour of short columns made from cement-bonded particle board, Faria, Gonçalo, Chastre Carlos, Lúcio Válter, and Nunes Ângela , Construction and Building Materials, 3//, Volume 40, p.60-69, (2013) AbstractWebsite

Cement bonded particle board (CBPB) is a composite material produced in plates consisting mainly of wood and cement, and may contain additives. This material is currently used in cladding, raised floors, dropped ceilings, prefabricated houses, office containers and various supplies to the building industry such as kitchens, bathrooms and furniture. It is composed of a type of wood Pinus pinaster and/or Pinus pinea, Portland cement type II, sodium silicate and aluminium sulphate. CBPB has been the subject of several studies with the purpose of enabling the use of other types of wood or even vegetable biomass, as the chemical compounds from wood (extractives and sugars) tend to inhibit of cement hydration. A study on the behaviour of short CBPB elements under compression was carried out in the Department of Civil Engineering of Universidade NOVA de Lisboa with the aim of enabling its use in structural elements. The study was supported by VIROC, the company which produces CBPB in Portugal. This paper presents and analyses the most significant results of a campaign of axial compression tests performed on 111 specimens of different heights and cross sections. The behaviour of CBPB specimens of varying slenderness was subjected to a more detailed analysis.

Cyclic compression behaviour of polymer concrete, Rodrigues, Chastre C., and Silva Manuel A. G. , Journal of Polymer Engineering, Volume 27, Number 6-7, p.525-545, (2007) Abstractrodrigues07si.pdfWebsite

Polymeric mortars or concrete are special building materials which can be used to repair or strengthen localized areas of structural elements. Following research on the behaviour of retrofitting reinforced concrete circular columns with FRP composite materials and bearing in mind the high strength of polymer concretes, it was decided to develop a solution to seismic retrofit of reinforced concrete columns with polymer concrete. The mechanical characteristics of different polymer concretes and especially their performance when subjected to cyclic axial compression, several bending tests, and monotonic and cyclic axial compression tests were studied, namely the compressive strength, the tensile strength on bending and the Young's modulus. Columns were also tested under axial compression and cyclic horizontal loads. The results of these tests are shown and interpreted. It is concluded that the improved behaviour in monotonic compression of polymer concrete is essentially associated with better strength characteristics of resin, whereas its superior behaviour under cyclic loading is linked to a smoother aggregate grading curve.

Cyclic loading behaviour of double strap bonded joints with CFRP and aluminium, Biscaia, Hugo, Micaelo Rui, Chastre Carlos, and Cardoso João , Key Engineering Materials , (2018) Abstract

The adhesively bonded joints behaviour under cyclic loading is not yet well understood due to its inherent complexity. Numerical approaches appear, therefore, as the easiest way to simulate such mechanical behaviour. In this work, double strap bonded joints with Carbon Fibres Reinforced Polymers (CFRP) and aluminium are numerically simulated and subjected to a cyclic loading history. In the numerical simulation, the Distinct Element Method (DEM) is used and it is assumed cohesive bi-linear bond-slip models with local damage of the interface. The evaluation of the bonded joints under cyclic loading is made by comparing the results with those simulated with a monotonic loading.

Damage Effect on Concrete Columns Confined with Carbon Composites, Faustino, Pedro, and Chastre Carlos , ACI Structural Journal, Volume 113, Number 4, (2016) AbstractWebsite

Five experimental cyclic tests were carried out on reinforced concrete rectangular columns with rounded corners, different condition (new and damaged) and different strengthening systems: that included confinement through carbon fiber (CFRP) jackets, anchor dowels, high strength repair mortar and external longitudinal stainless steel bars. Lateral load - displacement relationship, energy dissipation, ductility and curvature results were analyzed together with two different damage assessment classifications. The overall evaluation concludes that the use of external confinement with CFRP on RC columns is viable and of effective performance enhancement alone and combined with other techniques. Damaged columns that were retrofitted showed an increased load capacity up to 20% along with good ductile behavior within the limits of the US, European, Canadian and Japanese codes, with minor/moderate degree of damage at 1% drift ratio and moderate degree of damage at 2% drift ratio.

Delamination process analysis of FRP-to-parent material bonded joints with and without anchorage systems using the Distinct Element Method, Biscaia, Hugo C., Micaelo Rui, Teixeira João, and Chastre Carlos , Composite Structures, Volume 116, Issue September–October, p.104–119, (2014) AbstractWebsite

This study looks at the analysis of the interface between Fiber Reinforced Polymer (FRP)-to-parent material bonded interfaces. The performance of FRP-to-parent material bonded joints for the Externally Bonded Reinforcement (EBR) technique is numerically modelled with the PFC2D software which is based on the Distinct Element Method (DEM). It is believed that this represents the first time the DEM has been used to simulate the delamination process of FRP-to-parent material bonded joints. In order to validate the analysis performed with the DEM, a Pull-out test with no slip constrains was modelled and different linear bond-slip laws were assumed. The numerical results revealed that the DEM is capable of estimating with good accuracy the exact solutions of bond stresses, strains or slippages along the bonded length for linear bond-slip laws. The bi-linear law available in PFC2D was then compared to the numerical results obtained from other another code developed by the author. The delamination process of Pull-out tests with slip constrain at one of the free ends of the FRP plate is also described and analyzed. The results obtained from the DEM revealed that the delamination process ends with stiffness equal to the axial stiffness of the FRP plate. This evidence highlights the need to design mechanical anchor devices capable of preventing premature debonding which is known to occur on EBR systems.

Design method and verification of steel plate anchorages for FRP-to-concrete bonded interfaces, Biscaia, Hugo C., and Chastre Carlos , Composite Structures, 5/15/, Volume 192, p.52-66, (2018) AbstractWebsite

Concrete structures Externally Bonded Reinforced (EBR) with Fibre Reinforced Polymers (FRP) have been studied and used since the end of the last century. However, several issues need to be better studied in order to improve performance. The influence of size of anchorage plates used on Reinforced Concrete (RC) structures strengthened with EBR FRP composites, the external compressive stress to be applied on the anchorage plate and the numerical simulation of this region are some of the topics that need to be more carefully studied in order to clarify the performance of the FRP-to-concrete interface within the anchorage plate region. This study proposes a design methodology to estimate the amount of external compressive stress necessary to be applied on the anchorage plate of EBR systems with FRP composites, in order to avoid premature debonding. The external compressive stress imposed on the FRP composite is intended to simulate the effect produced by a mechanical anchorage system tightened to the EBR system. The results from the design proposal, when compared with the numerical ones, were efficient enough on the prediction of the bond strength improvement of FRP-to-concrete interfaces.

Design model for square RC columns under compression confined with CFRP, Faustino, Pedro, Chastre Carlos, and Paula Raquel , Composites Part B: Engineering, Volume 57, Issue February, p.187-198, (2014) Abstractfaustino_chastre_et_al._2014.pdfWebsite

The enhancement of the mechanical behaviour of reinforced concrete (RC) columns with regard to axial compression is an up-to-date concern, namely if the strengthening of existing structures is to be considered. In view of this, external confinement with FRP systems has been tested in order to become a feasible technique, since it seems to have important advantages over other systems such as its high strength and stiffness in relation to weight and its improvement of strength and ductility while confining RC columns. Square columns confined with FRP show a more complex interpretation of their behaviour, when compared to circular columns. Accordingly, the present work includes the analysis of two experimental programs regarding axial compression on CFRP confined RC columns: one on circular and square specimens with different corner radii; the other on square specimens with side lengths ranging from medium to large. Based on this, modelling equations are proposed to predict maximum axial load, axial strain and lateral strain, as well as the entire behaviour until failure with curves of axial load-axial strain and axial load-lateral strain. The modelling results show that the analytical curves are in general agreement with the presented experimental curves for a wide range of dimensions.

Determination of weathering degree of the Persepolis stone under laboratory and natural conditions using fuzzy inference system, Heidari, Mojtaba, Torabi-Kaveh Mehdi, Chastre Carlos, Ludovico-Marques Marco, Mohseni Hassan, and Akefi Hossein , Construction and Building Materials, Volume 145, p.28-41, (2017) Abstract

Weathering imposes vital effects on stony monuments. Mostly, the degree of weathering is determined by simple test results, ignoring simultaneous effects of various weathering factors. Hence, the main purpose of this study is to develop prediction models with fuzzy inference systems to determine the weathering degree of the Persepolis stone, using various accelerated ageing tests in laboratory condition and to extrapolate the results to the natural condition, considering climatic information. The results suggest reliable conformity between the prediction of the weathering degree of the stone and the weathering degree observed in the Persepolis complex in natural condition.

Development of an injectable grout for concrete repair and strengthening, Bras, Ana, Gião Rita, Lúcio Válter, and Chastre Carlos , Cement and Concrete Composites, (2013) AbstractWebsite

This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCE) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35°C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 minutes. In the hardened state, silica fumes increased not only the grout’s porosity but also the grout’s compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 days and beyond.

Double shear tests to evaluate the bond strength between GFRP/concrete elements, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composite Structures, Volume 94, Number 2, p.681-694, (2012) AbstractWebsite

Externally bonded reinforced systems have been widely used in civil engineering. However, the problems associated with bond between structural elements are not yet fully solved. As a consequence, many researchers have been proposing tests and techniques to standardize procedures and reach better agreement for design purposes. In the present paper, an experimental program is described that was developed to characterize the glass FRP/concrete interface by double shear tests made on 15 cm side cubes with GFRP bonded on two opposite faces. The GFRP wrap had two layers applied by the wet lay-up technique and three classes of concrete were considered. With the support of the experimental program, cohesion and friction angle for GFRP–concrete interfaces were found leading to different envelope failure laws, based on the Mohr–Coulomb failure criterion for each concrete class, capable of predicting GFRP debonding. Results are discussed.

Effect of consolidation treatments on mechanical behaviour of sandstone, Ludovico-Marques, Marco, and Chastre Carlos , Construction and Building Materials, 11/15/, Volume 70, p.473-482, (2014) AbstractWebsite

Experimental research was carried out about into ethyl silicate applications on sandstone samples. Consolidation was assessed by drilling strength, impregnation depth and also monotonic and cyclic uniaxial compressive tests in order to evaluate the compressive mechanical behaviour of treated sandstone. The stress–strain compression diagrams showed a significant increase in the values of mechanical parameters after consolidation treatments. The difference in compressive strength values between monotonic and cyclic compression disappears after the consolidation treatments. An equation of consolidation effect was obtained from an analytical model by means of compressive behaviour assessed by stress–strain diagrams. These sandstone samples have values of porosity similar to the more weathered variety of sandstone found in facades of monuments in the village of Atouguia da Baleia, in the western region of Portugal. The most important degradation pattern found on sandstone building stones is alveolization caused by salt crystallization since the Middle Ages.

Effect of salt crystallization ageing on the compressive behavior of sandstone blocks in historical buildings, Ludovico-Marques, Marco, and Chastre Carlos , Engineering Failure Analysis, 12//, Volume 26, p.247-257, (2012) AbstractWebsite

Sandstone building stones are important in the building elements of Portuguese monuments, particularly in the western and southern regions. Alveolization due to salt crystallization was the most important degradation pattern found in the old sandstone façades of buildings in the village of Atouguia da Baleia. Because weathering progressively increases porosity in stones, experimental research was conducted on the most porous variety of sandstone, which is similar to the type of stones found in the façades of ancient buildings in that village. An automatic salt crystallization accelerated ageing chamber was developed. Monotonic and cyclic uniaxial compressive tests were carried out on samples after sodium chloride crystallization ageing tests had been performed, in order to assess the compressive mechanical behavior of sandstone during accelerated ageing. The results of stress–strain compression diagrams showed a clear decreasing trend in the values of mechanical parameters during the salt crystallization ageing progress. The difference in compressive strength values between monotonic and cyclic compression also decreases with as salt crystallization ageing progresses. A predictive equation that correlates the compressive strength of sandstones with salt crystallization ageing cycles is proposed.

Estimations of the debonding process of aged joints through a new analytical method, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composite Structures, 2019/03/01/, Volume 211, p.577-595, (2019) AbstractWebsite

The estimation of the long-term durability of adhesively bonded interfaces between Fiber Reinforced Polymers (FRP) and concrete substrates is crucial because degradation potentiates FRP premature debonding. One of the main reasons for mistrusting the use of FRP composites is the premature debonding phenomenon, which, associated to degradation, has been preventing their widespread use. In this research work, an analytical model is proposed that introduces ageing to estimate the effects of degradation of Glass (G) FRP externally bonded to concrete. Cycles were used to experimentally accelerate ageing of beam specimens, namely, (i) salt fog cycles; (ii) wet-dry cycles with salted water; (iii) temperature cycles between −10 °C and +30 °C; and (iv) temperature cycles between +7.5 °C and +47.5 °C. Based on the experimental results obtained and a corresponding bond-slip curve, the analytical model predicts the complete debonding process between FRP composites and a substrate. Consequently, the temporal evolution of the degradation of the bonded interfaces can be calculated and compared with the initial situation prior to exposure. The effects of the environmental conditions are reported and compared.

Experimental and Numerical Modelling of Basalt Textile Reinforced Mortar Behavior Under Uniaxial Tensile Stress, Larrinaga, Pello, Chastre Carlos, Biscaia Hugo C., and San-José José T. , Materials & Design, Volume 55, Issue March, p.66-74, (2014) AbstractWebsite

During the last years several projects and studies have improved the knowledge about Textile Reinforced Mortar (TRM) technology. TRM has already been used in strengthening masonry and reinforced concrete structural elements such as walls, arches, columns and beams. This material is presented as a real alternative to the use of fibre-reinforced polymers (FRP) in situations where these composites have presented some drawbacks or their use is banned. Textile Reinforced Mortar show a complex mechanical behaviour derived from the heterogeneity of the constituent materials. This paper aims to deepen the knowledge of this composite material in terms of tensile behaviour. Following this scope, this paper presents an experimental campaign focused on thirty one TRM specimens reinforced with four different reinforcing ratios. The results are analysed and contrasted with two distinct models. i) the Aveston-Cooper-Kelly theory (ACK) which is based on a tri-linear analytical approach; and ii) a nonlinear numerical simulation with a 3D Finite Element code. The Finite Element Analysis (FEA) of the TRM tensile tests also showed no significant dependence on the basalt-to-mortar interface, i.e., the choice of a bond-slip curve in order to reproduce the bond stresses and slippages along the interface is irrelevant and it can be simply considered as rigid interface.

Experimental evaluation of bonding between CFRP laminates and different structural materials, Biscaia, Hugo, Chastre Carlos, Borba Isabel, Silva Cinderela, and Cruz David , Journal of Composites for Construction, Volume 20, Number 3, p.04015070, (2016) AbstractWebsite

This study presents an analysis of Carbon Fiber Reinforced Polymers (CFRP)-to-parent material interfaces based on 40 single-lap shear tests intended to highlight the strength of the interfaces under fracture mode II. Three different substrates are analyzed: timber;concrete and steel, using the same CFRP laminates and adhesive agent. The Externally Bonded Reinforcement (EBR) technique was used throughout the study. The results show that the CFRP-to-timber interfaces had the highest strength but also showed that these interfaces need a longer bonded length in order to reach maximum strength, i.e., CFRP-to-timber interfaces had the longest effective bond length. The local non-linear bond-slip curve of CFRP-to-concrete can be approximated to exponential curves, whereas the CFRP-to-timber or steel interfaces showed tri-linear and bi-linear bond-slip relations, respectively. Also, the CFRP-to-timber interfaces revealed the highest fracture energy.

Experimental investigation on the variability of the main mechanical properties of concrete produced with coarse recycled concrete aggregates, Pacheco, J., de Brito J., Chastre C., and Evangelista L. , Construction and Building Materials, 2019/03/20/, Volume 201, p.110-120, (2019) AbstractWebsite

Research on the variability of the properties of recycled aggregate concrete is lacking and is necessary for the development of reliability analyses and code calibration procedures. This paper presents an experimental programme on the within-batch variability of the compressive strength, Young’s modulus, and splitting tensile strength of several recycled and natural aggregate concrete mixes. The influence of the recycled concrete aggregates on the mechanical properties and variability of concrete is analysed and discussed and benchmarks with standard predictions for the variability of natural aggregate concrete are made. It was found that full recycled aggregate concrete incorporation did not increase the variability of any of the properties tested, but intermediate ratios of recycled aggregate incorporation did. The properties of high-strength concrete mixes were more variable than that of all other mixes, irrespective of recycled aggregate incorporation. All properties of all compositions were suitably modelled by normal distributions. The coarse recycled aggregates were sourced from concrete waste.

An experimental study of GFRP-to-concrete interfaces submitted to humidity cycles, Biscaia, Hugo C., Silva Manuel A. G., and Chastre Carlos , Composite Structures, 4//, Volume 110, Issue April, p.354-368, (2014) AbstractWebsite

Systems externally reinforced by bonded fibre reinforced polymers (FRP) are widely used in the retrofitting and strengthening of reinforced concrete (RC) structures. A drawback of the usage of this technique lies on the uncertainty of the long term behaviour of those reinforcements. Researchers have paid heed to this aspect and a number of tests and alternative techniques have recently been described. An experimental programme developed to supplement work of the authors recently published and which focused on specimens not submitted to aggressive environments is described. The specimens used have the same geometry as in the previous paper, but they were exposed to salt fog cycles and dry/wet cycles with salt water for periods of 3000 h, 5000 h and 10,000 h. The interface of the glass fiber polymeric composite (GFRP)-to-concrete was characterized after the systems underwent such aggressive conditions. The GFRP wrap comprised of two layers and wet lay-up technique was used on its preparation and application. The cohesion and friction angle for GFRP-to-concrete interfaces were measured tat selected stages of ageing process and envelope failure laws were obtained based on the Mohr–Coulomb failure criterion. Changes of 27% in cohesion and 8% in the friction angle were found due to the attack of the interface and consequences of the changes are examined.

Factors influencing the performance of externally bonded reinforcement systems of GFRP-to-concrete interfaces, Biscaia, Hugo C., Silva Manuel A. G., and Chastre Carlos , Materials and Structures, 2014/06/29, Volume 48, Issue 9, p.2961-2981, (2015) AbstractWebsite

Fibre reinforced polymer (FRP) composites may prematurely debond from the surface of concrete, i.e. before its elastic resistance is exhausted. This is a very common situation and can be aggravated if additional factors are not taken into account. These factors include the type of surface preparation, the exposure to aggressive environmental action, the tensile concrete strength or fatigue and creep loading to which the structural element may be subject. An experimental programme based on double shear tests was undertaken to analyse the influence of some of these factors on the performance of the interface between composite glass fibres (GFRP) and concrete. The results allowed the determination and comparison of maximum loads transmitted to the GFRP plates and maximum bond stresses obtained considering various surface treatments and aging conditions. Bond–slip curves were also determined. The experimental results are compared with those obtained from a numerical analysis.

A Finite Element Based Analysis of Double Strap Bonded Joints with CFRP and Aluminium, Biscaia, Hugo, Cardoso João, and Chastre Carlos , Key Engineering Materials, Volume 754, p.237-240, (2017) Abstract
n/a
Flexural strengthening of columns with CFRP composites and stainless steel: Cyclic behavior, Faustino, Pedro, and Chastre Carlos , Journal of Structural Engineering, 21 September 201, Volume 142, Number 2, p.04015136, (2016) AbstractWebsite

This study presents the testing, completion, and analysis of different external strengthening systems applied to rectangular reinforced concrete columns with rounded corners. The experimental study included confinement strengthening with carbon-fiberreinforcedpolymer (CFRP) sheets, longitudinal strengthening with CFRP laminates and confining CFRP jacket, longitudinal strengtheningwith stainless steel bars and confining CFRP jacket, tested column until reinforcing steel failure, repair and CFRP confining jacket,and longitudinal strengthening with stainless steel bars. The analysis of the experimental results included lateral load-displacement relationship, energy dissipation, ductility, and curvature damage assessment classifications. It was concluded that the use of externallongitudinal strengthening combined with CFRP confinement is effective for enhancing performance and is viable in terms of execution. The load capacity increase due to strengthening reached 36–46% with good ductile behavior (failure was reached at 4.4% drift ratio). Despite some differences between CFRP laminates and stainless steel, all columns presented moderate degrees of damage between 1 and 2% drift ratio and minor damage degree until 1% drift ratio.

Flexural Strengthening of Old Timber Floors with Laminated Carbon Fiber Reinforced Polymers, Biscaia, Hugo, Chastre Carlos, Cruz David, and Franco Noel , Journal of Composites for Construction, p.04016073, (2016) AbstractWebsite

A set of three old suspended timber floors were flexurally-strengthened with Carbon Fiber Reinforced Polymers (CFRP) strips in order to investigate the effectiveness of externally bonding FRP to their soffits. The specimens were from an old building and 740 mm-wide bands were transferred to the laboratory in order to be tested in a 4-point bending test. One specimen was tested with no strengthening system and the results obtained were used as reference values for comparison with the specimens those were externally bonded and reinforced (EBR) with CFRP strips. Two similar EBR systems were studied: (i) keeping both ends of the CFRP strips free of any restriction (traditional technique); and (ii) embedding both ends of the CFRP strips into the timber, thus providing a bonding anchorage of the strips (new technique). The installation of the new strengthening system comprises the opening of holes in the timber and the creation of a transition curve between the holes and the timber surface. This transition curve allows a smooth transition of the CFRP laminate between the hole and the timber surface, thus avoiding stress concentrations in this area. After the opening of the holes, the resin is applied inside the hole and on the beam surface, and then the CFRP laminate is mounted. The load-carrying capacity of the specimens, the rupture modes, the strains and bond stress distributions within the CFRP-to-timber interface are presented. A nonlinear numerical simulation of the specimens based on the mid-span cross-sectional equilibrium is also presented. The results showed that the use of the new strengthening system enhances the performance of the specimens when compared with the traditional strengthening system.

Flexural Strengthening of Old Timber Floors with Laminated Carbon Fiber-Reinforced Polymers, Biscaia, Hugo C., Chastre Carlos, Cruz David, and Franco Noel , Journal of Composites for Construction, Volume 21, Number 1, p.04016073, (2017) AbstractWebsite

A set of three old suspended timber floors were flexurally strengthened with carbon fiber–reinforced polymer (CFRP) strips in order to investigate the effectiveness of externally bonding FRP to their soffits. The specimens were from an old building and 740-mm-wide bands were transferred to the laboratory in order to be tested in a four-point bending test. One specimen was tested with no strengthening system and the results obtained were used as reference values for comparison with the specimens that were externally bonded and reinforced (EBR) with CFRP strips. Two similar EBR systems were studied: (1) keeping both ends of the CFRP strips free of any restriction (traditional technique), and (2) embedding both ends of the CFRP strips into the timber, thus providing a bonding anchorage of the strips (new technique). The installation of the new strengthening system comprises the opening of holes in the timber and the creation of a transition curve between the holes and the timber surface. This transition curve allows a smooth transition of the CFRP laminate between the hole and the timber surface, thus avoiding stress concentrations in this area. After the opening of the holes, the resin is applied inside the hole and on the beam surface, and then the CFRP laminate is mounted. The load-carrying capacity of the specimens, the rupture modes, and the strains and bond stress distributions within the CFRP-to-timber interface are presented. A nonlinear numerical simulation of the specimens based on the midspan cross-sectional equilibrium is also presented. The results showed that the use of the new strengthening system enhances the performance of the specimens when compared with the traditional strengthening system.

Gravity load effects on the behaviour of reinforced concrete beam critical zones subjected to cyclic loads, Gião, Rita, Lúcio Valter, and Chastre Carlos , Engineering Structures, 2019/02/15/, Volume 181, p.503-518, (2019) AbstractWebsite

The aim of the present study was to proceed to a numerical analysis of the gravity load effects on the behaviour of reinforced concrete beam critical zones when subjected to cyclic loads. A parametric study to assess the influence of different levels of gravity load on RC beam critical zones subjected to cyclic loading was carried out. For this purpose, assuming the level of gravity load as a variable parameter, a nonlinear numerical model of a beam-column connection, previously calibrated with experimental data, was used. In order to evaluate the gravity load effects in the global response, a numerical study of a RC frame system is also presented. The numerical results are analysed in terms of global hysteretic response, accumulated energy dissipation and equivalent viscous damping ratio. In this numerical study, it was observed that the hysteretic response depends on the load path. In the presence of higher gravity load levels, the structure hysteretic behaviour exhibits higher damage levels, associated to a failure mechanism corresponding to the formation of four span plastic hinges. Thus, the proper test procedure should involve the imposition of a reverse cyclic displacement history starting each cycle from the gravity load effects.

In-Plane Displacement and Strain Image Analysis, Almeida, Graça, Melício Fernando, Biscaia Hugo, Chastre Carlos, and Fonseca José Manuel , Computer-Aided Civil and Infrastructure Engineering, 24 February 2015, Volume 31, Number 4, p.292-304, (2016) AbstractWebsite

Measurements in civil engineering load tests usually require considerable time and complex procedures. Therefore, measurements are usually constrained by the number of sensors resulting in a restricted monitored area. Image processing analysis is an alternative way that enables the measurement of the complete area of interest with a simple and effective setup. In this article photo sequences taken during load displacement tests were captured by a digital camera and processed with image correlation algorithms. Three different image processing algorithms were used with real images taken from tests using specimens of PVC and Plexiglas. The data obtained from the image processing algorithms were also compared with the data from physical sensors. A complete displacement and strain map were obtained. Results show that the accuracy of the measurements obtained by photogrammetry is equivalent to that from the physical sensors but with much less equipment and fewer setup requirements.

Influence of external compressive stresses on the performance of GFRP-to-concrete interfaces subjected to aggressive environments: An experimental analysis, Biscaia, Hugo, Silva Manuel A. G., and Chastre Carlos , Journal of Composites for Construction , Volume 20, Issue 2, p.04015044, (2016) AbstractWebsite

Despite the fact that FRP composites are a reliable structural material with reasonable durability performance, the environment to which the strengthened structure is exposed can make the strengthening system vulnerable. In this study, the effectiveness of Externally Bonded Reinforcement (EBR) systems when external compressive stresses are applied to glass (G) FRP-to-concrete interfaces in several aggressive environments is analysed. The compressive stress imposed on the GFRP-to-concrete interface intends to simulate, for instance, the effect produced by a mechanical anchorage system applied to the EBR system. The design and the region to set those mechanical anchorage systems are not yet well understood and are mostly applied without really knowing how they will behave. This work shows an exhaustive experimental programme based on several double shear tests subjected to salt fog cycles, dry/wet cycles and two distinct temperature cycles: from -10ºC to +30ºC and +7.5ºC to +47.5ºC. The Mohr-Coulomb failure criterion was found to provide a good representation of the performance of the GFRP-to-concrete interface, and changes of cohesion and internal friction angle of those interfaces during the hours of exposure to the aggressive environments are reported.

Influence of Temperature Cycles on Bond between GFRP and Concrete, Silva, Manuel A. G., Biscaia Hugo, and Chastre Carlos , ACI Structural Journal, Volume 110, Issue 6, p.977-988, (2013) AbstractWebsite

Reinforced concrete (RC) beams externally strengthened with glass fiber-reinforced polymer (GFRP) strips bonded to the soffit may see their load-carrying capacity reduced due to environmental conditions—especially due to the deterioration of bond between the adhesively bonded laminates and concrete, causing premature failure.
More research has been published on the detachment of the laminate progressing from the anchorage zone than on failure induced by the formation of flexural or shear-flexural cracks in the midspan followed by fiber-reinforced polymer (FRP) separation and failure designated as intermediate crack (IC) debonding. An experimental program to study degradation of the GFRP laminate beam specimens after accelerated temperature cycles, namely: 1) freezing-and-thawing type; and 2) cycles of the same amplitude (40°C [104°F]) and an upper limit approximately 70% of the glass vitreous transition temperature of the resin, Tg, is described.
Effects on the bond stress and ultimate capacity are reported. Substantial differences between shear and bending-induced failure and a decrease of bond stresses and engagement of the laminates on the structural response are analyzed.

Lateral cyclic behaviour of RC columns confined with carbon fibres, Faustino, Pedro, Frade Pedro, and Chastre Carlos , Structures, February 2016, Volume 5, p.196-206, (2016) AbstractWebsite

Reinforced concrete (RC) columns with various strengthening systems and different conditions were tested to cyclic lateral and axial loading for the purpose of performance assessment. Tests included confinement strengthening with carbon-fiber-reinforced polymer (CFRP) sheets, longitudinal strengthening with CFRP laminates and confining CFRP jacket, longitudinal strengthening with stainless steel bars and confining CFRP jacket, tested column until reinforcing steel failure, repair and CFRP confining jacket, and longitudinal strengthening with stainless steel bars. The analysis of the tests results as to load-displacement relationship and energy dissipation led to the conclusion that the use of external longitudinal strengthening with CFRP confinement is effective for performance retrofitting and upgrading, and viable in terms of execution. The load capacity increase due to strengthening reached 36–46% with good ductile behaviour. Nonlinear numerical modelling was carried out using two approaches which represent reasonably well the global performance of the studied columns for the prediction of the ascending load-displacement relationship and the peak load values in each cycle.

Lifetime modelling of chloride induced corrosion in reinforced concrete structures with concrete with portland and blended cements, Faustino, Pedro, Chastre Carlos, Nunes Ângela, and Brás Ana , Structure and Infrastructure Engineering, 2016, Volume 12, Number 9, p.1013-1023, (2016) AbstractWebsite

This article discusses mathematical modelling of the long-term performance of concrete with different supplementary cementitious materials in a maritime environment. The research was carried out in the light of the national Portuguese application of the CEN standards with mandatory requirements for a performance-based design approach. Laboratory investigations were performed on concrete compositions based on CEM I and CEM II/B-L in which the cement was partially replaced by either 0% (reference composition) or 50% of low calcium fly ash (FA). Concrete compositions were made with the objective to achieve service lives of 50 and 100 years with regard to steel corrosion. Test results of compressive strength, chloride potential diffusion and electrical resistivity are reported for different curing ages of 28, 90, 180 and 365 days. Chloride diffusion results were used for the implementation of modelling equations in order to estimate the design lifetime regarding reinforcing steel corrosion. A performance-based approach using a probabilistic method was carried out and the results obtained are compared with the requirements according to the Portuguese prescriptive approach. The modelling results show that FA blended compositions have better performance compared to those with Portland cements, especially if curing ages beyond 28 days are considered.

Linear and nonlinear analysis of bond-slip models for interfaces between FRP composites and concrete, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composites Part B: Engineering, Volume 45, Number 1, p.1554-1568, (2013) AbstractWebsite

The paper analyses different analytical and numerical solutions for the debonding process of the FRP-to-concrete interface on shear tests with the FRP plate submitted to a tensile load in one of its ends. From the point of view of the state of the art, two different ways of finding the bond-slip curve from experiments are discussed and analysed. Essentially, three different linear bond-slip models, one exponential model and another power based function are employed in the numerical process. The results are analysed and compared. The differences found in the stress field along the interface, maximum load, maximum slip, ultimate slip, fracture energy and effective bond length are reported. The load-slip behaviour is also presented for the linear and non-linear models herein studied and the influence of the local bond-slip model on the debonding process is discussed. The numerical integration process used on the present study proved to be coherent with the analytical expressions determined for the linear bond-slip models and allowed to verify that maximum load transmittable to the FRP plate is influenced by the square root of the FRP stiffness and fracture energy even when nonlinear bond-slip models are assumed.

Mechanical Response of Anchored FRP bonded joints: A Nonlinear Analytical Approach, Biscaia, Hugo, Chastre Carlos, Silva Cinderela, and Franco Noel , Mechanics of Advanced Materials and Structures, (2018) Abstract

The paper presents a nonlinear analytical solution for the prediction of the full-range debonding response of mechanically-anchored FRP composites from the substrate. The nonlinear analytical approach predicts, for any monotonic loading history or bonded length the relative displacements (or slips) between materials, the strains in the FRP composite, the bond stresses within the interface and the stresses developed in the substrate. The load-slip responses FRP-to-substrate interfaces with a short and a long bonded lengths are motive of analysis and discussion. The solutions obtained from the proposed approach are also compared with other experimental results found in the literature.

Mechanical response of anchored FRP bonded joints: A nonlinear analytical approach, Biscaia, Hugo Charrinho, Chastre Carlos, Silva Cinderela, and Franco Noel , Mechanics of Advanced Materials and Structures, 2018/02/17, Volume 25, Number 3, p.238-252, (2018) AbstractWebsite

This article presents a nonlinear analytical solution for the prediction of the full-range debonding response of mechanically anchored, fiber-reinforced polymer (FRP) composites from the substrate. The nonlinear analytical approach predicts, for any monotonic loading history or bonded length, the relative displacements (or slips) between materials, the strains in the FRP composite, the bond stresses within the interface, and the stresses developed in the substrate. The load-slip responses of FRP-to-substrate interfaces with short and long bonded lengths are motives of analysis and discussion. The solutions obtained from the proposed approach are also compared with other experimental results found in the literature.

Modelação do comportamento mecânico em compressão de rochas granulares baseada em ensaios não destrutivos e quasi não destrutivos, Ludovico-Marques, Marco, Chastre Carlos, and Vasconcelos Graça , Mecânica Experimental, Number 19, p.101-110, (2011) Abstractrev_19_a10.pdfWebsite

No património edificado português as rochas granulares assumem importância relevante nos elementos construtivos presentes no património histórico e cultural, nomeadamente as pedras graníticas e areníticas. Tendo por objectivo a avaliação do comportamento mecânico de rochas granulares presentes no património edificado histórico foi realizado um estudo de investigação experimental sobre amostras dos litótipos seleccionados e que são representativos de rochas presentes no próprio edificado, em termos de propriedades petrográficas, físicas e mecânicas. Neste artigo apresenta-se um modelo analítico definido com base em ensaios experimentais que permite efectuar a simulação do comportamento das rochas em compressão uniaxial (diagramas de tensão-deformação), função de propriedades físicas e mecânicas obtidas através de ensaios não destrutivos e quasi não destrutivos. Este modelo permite desta forma a avaliação do comportamento mecânico de rochas granulares sem afectar a integridade do património histórico.

Modelling GFRP-to-concrete joints with interface finite elements with rupture based on the Mohr-Coulomb criterion, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Construction and Building Materials, 10//, Volume 47, p.261-273, (2013) AbstractWebsite

The strengthening of reinforced concrete structures by means of externally bonded fibre reinforced polymers (FRPs) is now routinely considered and applied in the retrofit or strengthening of structures. FRP composites have received a considerable attention from civil engineers in recent years due to the high strength-weight and stiffness/weight ratios when compared to other materials. However, when FRP composites are bonded to a concrete surface, there is a persistent potential problem that the FRP plates may debond prematurely from the concrete. This is a very important issue for the engineers who have to focus on the computational modelling of this phenomenon. Some studies can be found in literature on computational modelling. However, there is very little information about the best modelling of the interface between FRP composites and concrete and this work is intended to help bridge this gap. The computational analysis presented here is based on three-dimensional software which assumes the smeared crack model, and the interface finite elements (FEs) used have a rupture criteria based on the Mohr-Coulomb criterion with tension cut-off. The definition of these FEs was based on double shear tests that were performed specifically for this purpose and they have shown that the debonding phenomenon can be predicted with some accuracy. In total, 10 double shear models were studied and the results were compared with the 21 experimental tests performed. The double shear tests consisted of applying loads to 2 layered GFRP laminates bonded to a 150 mm concrete cube with a bonded area of 150 × 80 mm (length × width). Double shear models with and without a gap interface were considered in order to emphasize the importance of modelling the GFRP-to-concrete interface with interface finite elements. The effect of the concrete strength on the interface performance was also considered. An externally bonded reinforcement (EBR) concrete T-beam strengthened with 2 GFRP layers is presented to illustrate the application of the method. The wet lay-up technique was used for the external reinforcement of a reinforced concrete T-beam and then tested under a four point bending test until rupture. The results are reported and differences between the numerical and the experimental results are discussed.

Modelling the compressive mechanical behaviour of granite and sandstone historical building stones, Ludovico-Marques, Marco, Chastre Carlos, and Vasconcelos Graça , Construction and Building Materials, Volume 28, Number 1, p.372-381, (2012) AbstractWebsite

Building stones, particularly sandstone and granite, are very important in the building elements of Portugal’s historical and cultural heritage. Experimental research, based on uniaxial compressive tests, was carried out on selected representative samples of lithotypes of rocks used in historic built heritage, with a view to evaluating the compressive mechanical behaviour of different building stones. The results showed that porosity plays a central role in the compressive behaviour of granites and sandstones. As porosity can be evaluated in field conditions with non-destructive tests it was decided to derive an analytical model to predict compressive behaviour based on the knowledge of porosity of the building stones. A cubic polynomial function was adopted to describe the pre-peak regime under compression to implement the model. Furthermore, a statistical correlation between mechanical and porosity data had to be defined. Good agreement between experimental and analytical compressive stress–strain diagrams, from which the mechanical properties like compressive strength and modulus of elasticity can be derived, was achieved.

Monotonic and quasi-static cyclic bond response of CFRP-to-steel joints after salt fog exposure, Yang, Yongming, Biscaia Hugo, Silva Manuel A. G., and Chastre Carlos , Composites Part B: Engineering, 2019/07/01/, Volume 168, p.532-549, (2019) AbstractWebsite

Deterioration of adhesively bonded CFRP/steel systems in salt fog environment, i.e., deicing salts and ocean environments, has to be taken into account in the design of steel strengthened structures. In the present work, monotonic and quasi-static cyclic loading were applied to CFRP-to-steel double strap joints for two kinds of CFRP laminates after being aged for a period of 5000 h to evaluate the bond behavior. The bonded joints exposed to salt fog had a different failure mode than that observed in the control specimens (0 h of exposure). The severe reduction of the maximum bond stress resulted from damage initiation that occurred in the corrosion region of the steel substrate, associated with final partial rupture on the corroded steel substrate around the edge of the bonded area: it was also correlated with reduced load carrying capacity. Results of pseudo-cyclic tests showed that the relationship between a local damage parameter (D) and normalized local dissipated energy (Wd/Gf) and the normalized slip increment (ΔS/ΔSult) exhibited almost the same trend in the un-aged and aged bonded joints. The normalized slip increment can be seen as a direct indicator for the local and global damage for the un-aged and aged bonded joints. However, monotonic and quasi-static cyclic tests results revealed that the stress concentration due to local corrosion of steel substrate could lead to brittle rupture or accelerated cumulative damage once the aged bonded interface had become weaker. The bonded joints have exhibited also a smaller relative deformation capacity between CFRP and steel.

Monotonic axial behavior and modelling of RC circular columns confined with CFRP, Chastre, Carlos, and Silva Manuel A. G. , Engineering Structures, Aug, Volume 32, Number 8, p.2268-2277, (2010) AbstractWebsite

The retrofit of reinforced concrete columns with FRP jackets has received considerable attention in recent years. The advantages of this technique compared to other similar techniques include the high strength-weight and stiffness-weight ratios of FRP (Fibre Reinforced Plastics), the strength and ductility increase of RC columns confined with FRP jackets as well as the fact that FRP external shells prevent or mitigate environmental degradation of the concrete and consequent corrosion of the steel reinforcement. Furthermore, this method also reduces the column transversal deformation and prevents the buckling of longitudinal reinforcement. Twenty five experimental tests were carried out on reinforced concrete columns confined with CFRP composites, and subjected to axial monotonic compression. In order to evaluate the influence of several parameters on the mechanical behavior of the columns, the height of the columns was maintained, while changing other parameters: the diameter of the columns, the type of material (plain or reinforced concrete), the steel hoop spacing of the RC columns and the number of CFRP layers. Predictive equations, based on the experimental analysis, are proposed to estimate the compressive strength of the confined concrete, the maximum axial load and the axial or the lateral failure strain of circular RC columns jacketed with CFRP. A stress-strain model for CFRP confined concrete in compression, which considers the effect of the CFRP and the transversal reinforcement on the confined compressive strength of the column is also proposed. The curves, axial load versus axial or lateral strain of the RC column, are simulated based on the stress-strain model and include the longitudinal reinforcement effect. The results demonstrate that the model and the predictive equations represent very well the axial compression behavior of RC circular columns confined with CFRP. The applicability of this model to a large spectrum of RC column dimensions is its main advantage.

A new discrete method to model unidirectional FRP-to-parent material bonded joints subjected to mechanical loads, Biscaia, Hugo C., Chastre Carlos, and Viegas André , Composite Structures, 3//, Volume 121, p.280-295, (2015) AbstractWebsite

Nowadays fiber reinforced polymer (FRP) composites play an important role in the strengthening of structures. Different methods can be used to apply these materials: the externally bonded reinforcement (EBR), and the near surface mounted (NSM) using strips and NSM rods. There are only a few studies comparing these methods or presenting an efficient model to simulate these strengthening techniques. This study looks mainly at the analysis of the interface between FRP-to-parent material bonded joints. The paper examines, through a new discrete model based on axial and shear springs, the performance of FRP-to-parent material bonded joints for EBR or NSM techniques using strips or composite rods. In order to implement the model a routine in MATLAB was developed and several bond–slip curves were assumed. The results revealed that load–slip curves or bond stresses, strains or slippages along the bonded length obtained from several bond–slip curves are similar to the analytical and other numerical solutions found in literature. In what concerns the adhesion between two different materials, and assuming the same bond characteristics for the three fiber strengthening techniques, the NSM system using FRP strips had the highest maximum load transmitted to the FRP strip combined with the lowest effective bond length. The results obtained from the proposed model were also very accurate with that obtained from an analytical solution found in literature that simulates the debonding phenomenon of FRP-to-concrete interfaces between to adjacent cracks.

Non-linear analytical model of composites based on basalt textile reinforced mortar under uniaxial tension, Larrinaga, Pello, Chastre Carlos, San-José José T., and Garmendia Leire , Composites Part B: Engineering, 12//, Volume 55, p.518-527, (2013) AbstractWebsite

The recent development of inorganic based composites as low-cost materials in reinforced concrete structural strengthening and precast thin-walled components, requires the creation of models that predict the mechanical behaviour of these materials. Textile Reinforced Mortar (TRM) shows complex stress–strain behaviour in tension derived from the heterogeneity of its constituent materials. This complexity is mainly caused by the formation of several cracks in the inorganic matrix. The multiple cracking leads to a decrease in structural stiffness. Due to the severe conditions of the serviceability limit state in structural elements, the prediction of the stress–strain curve is essential for design and calculation purposes. After checking other models, an empirical nonlinear approach, which is based on the crack control expression included in the Eurocode 2, is proposed in this paper. Following this scope, this paper presents an experimental campaign focused on 31 TRM specimens reinforced with four different reinforcing ratios. The results are analysed and satisfactorily contrasted with the presented non-linear approach.

A Nonlinear Analytical model to predict The full-range debonding process of FRP-to-parent material interfaces free of any mechanical anchorage devices, Biscaia, Hugo C., Borba Isabel S., Silva Cinderela, and Chastre Carlos , Composite Structures, 15 March 2016, Volume 138, p.52-63, (2016) AbstractWebsite

Ever since Fibre Reinforced Polymers (FRP) began to be used in the repair or strengthening of structural elements, the premature debonding of the FRP composite from the substrate has been an important drawback that have been motive of several studies. The importance of knowing and describing the full-range behaviour of FRP-to-parent material interfaces rigorously is therefore urgent. However, at present, there are no analytical solutions that describe the full-range behaviour of such interfaces that help us to understand the full debonding phenomena of FRP-to-parent material interfaces free of any mechanical anchorage devices. Therefore, the aim of this study is to contribute the advances of that knowledge through an analytical solution by means of an exponential bond-slip model that is known to represent the nonlinearities involved in the debonding process of the FRP composite from the substrate. Analytical solutions for the slips, strains in the FRP composite, bond stress distributions along the bonded interface and stresses in the substrate are presented. A full-range load-slip analysis is also discussed.

Nonlinear numerical analysis of the debonding failure process of FRP-to-concrete interfaces, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composites Part B: Engineering, Volume 50, p.210-223, (2013) AbstractWebsite

The paper analyses numerical solutions for the process leading to debonding failure of fiber reinforced polymers (FRP)-to-concrete interfaces in shear tests with the FRP plate subjected to a tensile load at one end. Any realistic local nonlinear bond-slip law can be used in the numerical analysis proposed in the present study. However, only a Popovics’ type expression is employed in the numerical process due to its use in different studies found in the literature. Effective bond length (Leff) is discussed and an expression depending on the Popovics’ constant (nP) is proposed to calculate it. Assuming a fracture in pure Mode II, the debonding process is analyzed in detail and distributions of bond stresses and strains in the FRP plate along the interface are presented. The load-displacement behaviour is also presented and the influence of the local bond-slip law on the debonding process is discussed.

Numerical analysis of FRP anchorage zones with variable width, Biscaia, Hugo C., Micaelo Rui, Teixeira João, and Chastre Carlos , Composites Part B: Engineering, 11//, Volume 67, p.410-426, (2014) AbstractWebsite

The use of Fibre Reinforced Polymers (FRP) has recently become widespread in the construction industry. However, some drawbacks related to premature debonding of the FRP composites from the bonded substrates have been identified. One of the solutions proposed is the implementation of mechanical anchorage systems. Although some design guidelines have been developed, the actual knowledge continues to be rather limited. Thus, designers and researchers have not yet achieved any consensus on the efficiency of any particular anchor device in delaying or preventing the premature debonding failure mode that can occur in Externally Bonded Reinforcement (EBR) systems. This paper studies the debonding phenomenon of FRP anchoring systems with a linear variable width, with a numerical analysis based on the Distinct Element Method (DEM). Combined systems with constant and variable width are also discussed. The FRP-to-parent material interfaces are modelled with a rigid-linear softening bond–slip law. The numerical results showed that it is possible to attain the FRP rupture force with a variable width solution. This solution is particularly attractive when the bonded length is shorter than the effective bonded length because the strength of the interface can be highly incremented.

Numerical modelling of the effects of elevated service temperatures on the debonding process of frp-to-concrete bonded joints, Biscaia, Hugo C., Chastre Carlos, Viegas André, and Franco Noel , Composites Part B: Engineering, Volume 70, p.64-79, (2015) AbstractWebsite

There are many issues concerning the performance behaviour of FRP-to-concrete interfaces at elevated service temperatures (EST). At EST, i.e. slightly above the glass transition temperature (Tg), some properties associated with the FRP composites, such as the stiffness, strength or the bond characteristics, degrade. This is a crucial issue and there are only a few studies that take into account such effects on FRP-to-concrete interfaces at EST. This paper examines, through a numerical analysis, the performance of FRP-to-concrete bonded joints at EST using a new discrete model based on truss elements and shear springs. The External Bonded Reinforcement (EBR) systems subjected to EST are analyzed. The numerical discrete model was implemented in a MATLAB routine and the bond-slip curves of the interfaces at EST were obtained from a model found in literature. The numerical results revealed that the interface at EST behaves similarly to one with two equal mechanical loads applied at both ends of the FRP plate. The load-slip curves or bond stresses, strains or slippages along the bonded length obtained from several bond-slip curves at different temperatures were obtained. Two different single-lap shear tests were simulated at steady-state (steady temperature followed by load increase) and transient state (steady load followed by temperature increase). Regarding the influence of the temperature on the adhesion between the FRP and concrete, the results showed that an increase in the temperature at an earlier situation, i.e. during a period where temperature had no influence in the concrete deformations, leads to an increase in the effective bond length of the interface affecting the initial strength of the interface.

Old suspended timber floors flexurally-strengthened with different structural materials, Biscaia, Hugo, Franco Noel, Nunes Ricardo, and Chastre Carlos , Key Engineering Materials, Volume 713, p.78-81, (2016) Abstract

The design of timber beams has strict limits when it comes to the Serviceability Limit States (SLS) either in short-term or in long-term deflections. In order to face this aspect efficiently, the increase of the cross section of the beams might be considered as a solution. However, the prohibitive increase of the costs associated to this solution or the change of the initial architecturedesign of the building, opens the opportunity to find new and more efficient solutions. In that way, the use of additional reinforcements to the timber beams may be seen as a promising solution because either new or old structures would keep always their original aesthetical aspect with no significant self-weight increase and improving their behaviour to short and long-term actions.Therefore, the current study is dedicated to the analysis of composite timber beams where Fiber Reinforcement Polymers (FRP), steel or stainless steel are used to improve the stiffness, strength and deflection behaviour of old suspended timber floors. An experimental program was conducted where old suspended timber floors reinforced with CFRP strips were subjected to 4-point bending tests. A simplify nonlinear numerical model was developed to simulate the bending behaviour of the specimens and several other cases with other reinforcement configurations and different structural materials were assumed. The numerical analysis herein presented also takes into account both Ultimate and Serviceability Limit States of the reinforced specimens.

Performance analysis of load–strain models for circular columns confined with FRP composites, Marques, Pedro Faustino, and Chastre Carlos , Composite Structures, Volume 94, Number 11, p.3115-3131, (2012) Abstractmarques__chastre_2012.pdfWebsite

The use of FRP composites for the confinement of concrete has become an important aspect to consider on strengthening of concrete columns. It is important therefore that accurate modelling tools are available for the design of this system considering, not only the peak values of load and strain, but also the complete stress–strain behaviour. A wide group of authors have proposed several models specific for FRP-confined concrete based either on theoretical assumptions (analysis-oriented-models – AOMs) or on mathematical calibration from testing results (design-oriented-models – DOMs). This article carries out the implementation and analysis of nine existing models for circular concrete columns in view of axially tested reinforced concrete columns confined with CFRP with three different diameters: 150; 250 and 400 mm. The global shape of curves, peak compressive load, stress–strain relation, axial-to-lateral relation and dilation response were studied to conclude which models’ curves were closer to tests. Quantification of errors in face of the testing results was carried out for the most important parameters – ultimate load, strain and lateral stress – as well as for other curve parameters. Some models are accurate in predicting the peak load, though only few can accurately predict the load–strain and dilation behaviour.

Prediction of the interfacial performance of CFRP laminates and old timber bonded joints with different strengthening techniques, Biscaia, Hugo C., Chastre Carlos, Cruz David, and Viegas André , Composites Part B: Engineering, 1/1/, Volume 108, p.1-17, (2017) AbstractWebsite

Fiber Reinforced Polymers (FRP) is a recent technique to strengthen timber structures and the studies available discussing the debonding between these materials are limited. Therefore, the bond assessment between FRP composites and timber substrates is a topic that needs clarification. The present work analyses the debonding process between Carbon (C) FRP laminates and timber with rupture modes consistent with Mode II interfacial fracture, i.e. with the sliding mode where the bond stresses act parallel to the plane of the bonding surface. Several single-lap shear tests were performed and the experiments showed a nonlinear local behaviour of the CFRP-to-timber interface. An interfacial bond-slip model and its calibration procedure were also presented. Furthermore, the calibrated nonlinear bond-slip model was implemented in a numerical approach where the FRP composite and the adhesive are simulated by linear and nonlinear springs and the substrate is assumed rigid. The following influences on the debonding process of the CFRP-to-timber interface were also analysed: (i) the bonding technique (Externally Bonded Reinforcement - EBR; and Near Surface Mounted - NSM); and (ii) the use of an additional device to mechanically anchor the CFRP laminate. Besides the determination of the effective bond length for each bonding technique, a new concept defining the length beyond which the force at the anchorage device does not decrease with the bonded length and a proposal to estimate its value for any bonded length was also presented and discussed. The experimental tests have shown that the NSM technique has a better performance compared to the EBR technique, independently of the installation of mechanical anchorage devices. In the case of the EBR technique, the strains in the CFRP laminate increased at its vicinities due to the clamping force applied to the anchors, which affected the final strength of the interface.

Probabilistic Conversion of the Compressive Strength of Cubes to Cylinders of Natural and Recycled Aggregate Concrete Specimens, Pacheco, João Nuno, de Brito Jorge, Chastre Carlos, and Evangelista Luís , Materials, Volume 12, Number 2, p.280, (2019) AbstractWebsite

This paper investigates the effect of recycled coarse aggregate incorporation on the relationship between 150 mm cubic and Փ 150 mm cylindrical compressive strength (the reference strength of standards) by comparing data from recycled and natural aggregate concrete compositions in which both cubes and cylinders were tested. A conversion factor from cubic to cylindrical strength is proposed in two versions: A deterministic and a probabilistic one. Such factor has not been studied before and researchers have been converting cubic data as if natural aggregate concrete were tested. The probabilistic factor is intended for reliability analyses on the structural behaviour of recycled aggregate concrete using data from laboratory cube tests. It was found that the incorporation of recycled coarse aggregates sourced from concrete waste significantly decreases the expected value of the factor but the factor’s scatter is relatively unaffected.

Reforço de Vigas de Betão Armado com Armaduras Pós‑Instaladas de Aço Inox ou de Compósitos de FRP, Chastre, Carlos, Biscaia Hugo, and Franco Noel , Mecânica Experimental, Volume 28, p.39-46, (2017) AbstractWebsite

Neste artigo apresentam-se e analisam-se um conjunto de ensaios realizados em vigas de betão armado reforçadas com armaduras pós-instaladas de aço ou de FRP, incluindo os referentes a uma nova técnica (CREatE) desenvolvida na FCT NOVA. Os resultados experimentais permitiram concluir que a técnica CREatE possibilita aumentos de resistência e ductilidade consideráveis face às técnicas tradicionais.

Reforço de vigas em betão armado com armaduras exteriores de FRP, Monteiro, António, Chastre Carlos, Biscaia Hugo, and Franco Noel , Revista Internacional TechITT, Jan. 2017, Volume 15, Number 40, p.48-60, (2017) AbstractWebsite

A utilização de Polímeros Reforçados com Fibras (FRP) no reforço de estruturas de Betão Armado (BA) tem tido cada vez mais aceitação devido à sua elevada resistência e rigidez, baixo peso específico e excelente resistência aos efeitos dos agentes ambientais. No entanto, actualmente, é comum utilizarem-se técnicas de reforço que dificilmente permitem tirar partido da resistência total destes materiais. Com o objectivo de explorar a capacidade total de Polímeros Reforçados com Fibras de Carbono (CFRP), foram estudadas e desenvolvidas duas novas técnicas de reforço de vigas à flexão designadas por Continuous Reinforcement Embedded at Ends (CREatE) e Horizontal Near Surface Mounted Reinforcement (HNSMR). Posteriormente realizou-se um estudo comparativo entre o desempenho destes sistemas de reforço e o de duas outras técnicas já estudadas e usuais, nomeadamente os sistemas Externally Bonded Reinforcement (EBR) e Near Surface Mounted Reinforcement (NSMR). A técnica CREatE provou ser a mais eficaz de todas as alternativas testadas mobilizando a totalidade do compósito de CFRP e dotando as vigas de BA com uma maior capacidade resistente e com uma ductilidade mais elevada.Como complemento deste trabalho experimental, desenvolveu-se também um programa de cálculo em MATLAB, capaz de simular o problema em estudo através de um modelo numérico de análise não linear através do equilíbrio de secções. A representatividade dos dados obtidos foi verificada através de uma análise comparativa entre os valores numéricos e os obtidos experimentalmente.The use of Fiber Reinforced Polymers (FRP) in order to strengthen Reinforced Concrete (RC) structures has been increasingly accepted due to their strength and stiffness, low weight and excellent resistance to the effects of environmental aggressive agents. However, the bonding techniques available and described in the literature can not allow the full use of the mechanical properties of these materials and premature failures are often observed and described by several researchers. In order to explore the full capacity of CFRP composites, two new bonding strengthening techniques of RC beams when subjected to 4-point bending tests were studied and developed. For these new techniques, the designation of Continuous Reinforcement Embedded at Ends (CREatE) and Horizontal Near Surface Mounted Reinforcement (HNSMR) has been assigned. Posteriorly, a comparative study has been carried out between those strengthening systems performance and two traditional techniques, namely, the Externally Bonded Reinforcement (EBR) and Near Surface Mounted Reinforcement (NSMR). The CREatE technique has proved to be the most effective of all alternatives tested, with the full utilization of the CFRP composite and the highest strength, combined with the highest ductility. A code using MATLAB software was developed as a complement of this experimental work, which is able to simulate the problem under study through a nonlinear numerical model based on the equilibrium of sections. The representativeness of the numerical data has been verified afterwards through a comparative analysis between those and the experimental results.

Scatter of constitutive models of the mechanical properties of concrete: comparison of major international codes, Pacheco, João Nuno, de Brito Jorge, Chastre Carlos, and Evangelista Luís , Journal of Advanced Concrete Technology, March 19, 2019, Volume 17, Number 3, p.102-125, (2019) AbstractWebsite

An investigation on the scatter of code-type constitutive models that relate compressive strength (fc) with tensile strength (fct) and Young’s modulus (Ec) of standard concrete specimens is presented. The influence of the mix design on the accuracy of the fc vs. fct and fc vs. Ecrelationships is discussed, with emphasis on the lithological type and morphology of the coarse aggregates. The uncertainty of the constitutive models is analysed in probabilistic terms and random variables that model the uncertainty of the fc vs. fct and fc vs. Ec relationships are proposed for reliability analyses of serviceability limit states. The suitability of the models proposed is assessed through preliminary conservative estimates of their design values.

A simple analytical approach for creep analysis of EB-FRP systems, Biscaia, H., and Chastre C. , Key Engineering Materials , (2018) Abstract

Based on a few experimental results available in the literature, this work presents a simple analytical approach that allows the study of the long-term behaviour of CFRP-to-concrete interfaces under an initial sustaining load. Only the elastic regime is studied, which means that the interfacial maximum bond stress and maximum slip are never exceeded. Therefore, the maximum initial load to be sustained by the joints is limited by its corresponding elastic value. The analytical results provided by the proposed model are compared with some experimental results found in the literature. The results showed strain redistribution throughout the bonded length over the time.

A Simple Method for the Determination of the Bond-Slip Model of Artificially Aged Joints, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Journal of Composites for Construction, Volume 23, Number 4, p.04019028, (2019) AbstractWebsite

The durability of adhesively bonded fiber-reinforced polymers (FRP) and concrete substrates has been the subject of recent studies. The degradation of bonded interfaces conjugated with other factors that affect the interface strength may compromise the potentialities of using FRP in externally bonded reinforced (EBR) concrete structures. However, the estimation of the effects of degradation on these bonded interfaces and the analytical methodologies to quantify them are not fully understood. The present work focuses on a local bond-slip model characterized by two parameters for which the values are obtained experimentally. Then, the determination of the local bond-slip relationship of a glass (G) FRP-to-concrete interface can be estimated. The assessment of the degradation of the bonded interface when subjected to cycles of (1) salt fog; (2) wet-dry environments with salt water; (3) temperatures between −10°C and +30°C; and (4) temperatures between +7.5°C and +47.5°C is presented. The results obtained using the proposed bond-slip model led to the conclusion that after 10,000 h of exposure to temperature cycles between −10°C and +30°C, there was a small change in the GFRP-to-concrete interface performance, whereas the effects on the bonded interface for the specimens subjected to temperature cycles between +7.5°C and +47.5°C were far more most severe.

Size and Relative Stiffness Effects on Compressive Failure of Concrete Columns Wrapped with Glass FRP, Silva, M. A. G., and Rodrigues C. C. , Journal of Materials in Civil Engineering, Volume 18, Issue 3, p.334-342, (2006) AbstractWebsite

Structural design relies essentially on tests made on cylinders of small size to estimate the probability of failure of prototype members, since full-scale testing of structures to determine their strength is not feasible. The confidence that such scale modeling deserves in terms of representation of actual behavior needs careful examination, due to such factors as material nonlinearities, difficulties of scale representation of particulate materials, and sometimes the impossibility of simultaneously satisfying independent dimensionless parameters. Some failures explained by linear fracture mechanics are associable with strong size effects, as opposed to the cases where small cracks are a material property. Besides research centered on these problems, a number of studies of scale effects have been associated with the increased probability of finding a flaw in larger objects. In fact, geometric similitude may coexist with microscopic randomness of flaws that cause size effects to appear. The type of material of the object under study may also be a decisive factor. For example, scatter of the mechanical properties in unidirectional fiber-reinforced polymers (FRPs) is much larger than in metals due to a larger density of flaws. Thus the strength of FRP laminates may depend on the volume of material involved. Strengthening reinforced concrete columns with FRP wraps leads to new constitutive laws for the overall response of the columns and requires small-scale testing followed by extrapolation for design use. The present paper focuses on the difficulties of this step, based on the experimental data obtained. The questions mentioned above are addressed, and the relevance of the adequate representation of the lateral stiffness of the FRP jacket in the scaled cylinders is emphasized. The paper also addresses the problem of testing confined cylinders with a given slenderness ratio H/D=height/diameter, within the range usually characteristic of short columns, and extrapolating the results for columns of different H/D. The importance of the parameter (thickness of jacket/diameter of column, representative of stiffness of jacket/stiffness of concrete core) is also examined. The influence of the parameter is shown to be relatively minor, whereas the nonscaling of the relative stiffness of the core and jacket would be a major cause of error. The experimental data, in terms of strain and strength, are also compared with numerical models proposed in the literature, and the quality of the approximations is analyzed.

A smeared crack analysis of reinforced concrete T-beams strengthened with GFRP composites, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Engineering Structures, 11//, Volume 56, p.1346-1361, (2013) AbstractWebsite

The strengthening of reinforced concrete structures with laminates of fibre reinforced polymeric (FRP) matrix has received considerable attention, although there still is lack of information on the more adequate modelling of the interface between FRP composites and concrete. An experimental programme is described and was designed to: (i) characterise glass FRP-to-concrete interface by shear tests; (ii) analyse reinforced concrete T-beams with external GFRP plates. Double shear tests were carried out based on 15 cm cubes with GFRP bonded to two opposite faces. The concrete T-beams were 3.0 m long and 0.28 m high and were loaded till rupture in 4-point bending tests. The external reinforcement system showed great strength increment in relation to the non retrofitted T-beam, confirming to be an effective approach to the flexural strengthening of RC beams. The computational analysis was based on a three dimensional smeared crack model. In total, 22 computational analyses were made. Models with and without interface FE associated with Mohr–Coulomb failure criterion for the FRP-to-concrete interface were defined and different strength types of concrete were considered. The rigid interface does not predict the rupture of the T-beam with precision; however, the results obtained for low concrete strengths revealed that rigid interfaces can be assumed when conjugated with the fixed crack approach. Consequently, a slightly stiffer response of the beam is obtained. The maximum bond stresses obtained from Finite Element Analysis (FEA) revealed that the models with rigid interfaces developed lower bond stresses due to the lack of relative displacements between both materials. The effects of assuming either fixed or rotated crack approaches were also compared. The rotated crack conjugated to a fine mesh in the vicinity of the GFRP-to-concrete stress led to a very good estimation of the bond stresses along the interface. The prediction of the T-beam rupture was also estimated with better results when the rotated crack was used in the model. In general, the FEA predicted with very good results the de-bonding of the GFRP-to-concrete interface of T-beams externally bonded with GFRP composites.

Stainless steel bonded to concrete: An experimental assessment using the DIC technique, Biscaia, Hugo, Franco Noel, and Chastre Carlos , International Journal of Concrete Structures and Materials, January 30, Volume 12, Number 1, (2018) AbstractWebsite

The durability performance of stainless steel makes it an interesting alternative for the structural strengthening of reinforced concrete. Like external steel plates or fibre reinforced polymers, stainless steel can be applied using externally bonded reinforcement (EBR) or the near surface mounted (NSM) bonding techniques. In the present work, a set of single-lap shear tests were carried out using the EBR and NSM bonding techniques. The evaluation of the performance of the bonding interfaces was done with the help of the digital image correlation (DIC) technique. The tests showed that the measurements gathered with DIC should be used with caution, since there is noise in the distribution of the slips and only the slips greater than one-tenth of a millimetre were fairly well predicted. For this reason, the slips had to be smoothed out to make it easier to determine the strains in the stainless steel and the bond stress transfer between materials, which helps to determine the bond–slip relationship of the interface. Moreover, the DIC technique allowed to identify all the states developed within the interface through the load–slip responses which were also closely predicted with other monitoring devices. Considering the NSM and the EBR samples with the same bonded lengths, it can be stated that the NSM system has the best performance due to their higher strength, being observed the rupture of the stainless steel in the samples with bond lengths of 200 and 300 mm. Associated with this higher strength, the NSM specimens had an effective bond length of 168 mm which is 71.5% of that obtained for the EBR specimens (235 mm). A trapezoidal and a power functions are the proposed shapes to describe the interfacial bond–slip relationships of the NSM and EBR systems, respectively, where the maximum bond stress in the former system is 1.8 times the maximum bond stress of the latter one.

Statistical analysis of Portuguese ready-mixed concrete production, Pacheco, João Nuno, de Brito Jorge, Chastre Carlos, and Evangelista Luís , Construction and Building Materials, 2019/06/10/, Volume 209, p.283-294, (2019) AbstractWebsite

This paper evaluates and compares the statistics of compressive strength data from three Portuguese ready-mixed concrete plants. A hierarchical model showed that different groups of concrete strength records are not statistically equivalent, even if they were produced in the same plant and using the same concrete composition. This finding is related to autocorrelation. For the same specified strength class, compositions produced less often result in higher average compressive strength and variability. The statistics of one of the plants were quite different from those of the others, even though the concrete of this plant also complied with the specifications. It was found that the average compressive strength of a mix may be quite dependent on the plant that produced it, even if the compressive strength complies with quality control specifications. Conformity with the target slump and strength class was checked following the conformity criteria of EN 206-1 for continuous production. Nonconformity with slump is more frequent than failure to comply with the strength class. A bias factor for reliability analyses was proposed.

Uncertainty models of reinforced concrete beams in bending: code comparison and recycled aggregate incorporation, Pacheco, J., de Brito J., Chastre C., and Evangelista L. , Journal of Structural Engineering, 2019/04/01, Volume 145, Number 4, p.04019013, (2019) AbstractWebsite

The bias factor of the Eurocode 2 [CEN (European Committee for Standardization) (2008). Eurocode 2: Design of ConcreteStructures–Part 1-1: General Rules and Rules for Buildings] and ACI 318 [ACI (American Concrete Institute) (2014). Building CodeRequirements for Structural Concrete and Commentary] flexural resistance models of reinforced concrete beams are compared withemphasis on the effect of the incorporation of coarse recycled aggregates sourced from concrete waste. The bias factor of the yielding momentcalculations according to both codes is also investigated, and the bias in the cracking moment when Eurocode 2 material clauses are used. Thedatabase was composed of 174 beams, and the criteria that led to its development are discussed. The effect of recycled aggregate incorporationon the statistical descriptors of the bias factor is evaluated and probabilistic modeling using lognormal distributions is argued for. Preliminarypartial safety factors for the bias factor of recycled aggregate concrete beams are proposed. No significant differences in the bias of theultimate moment were found between the two comparison vectors: Eurocode 2 versus ACI 318 specifications and recycled versus naturalcoarse aggregate. The bias of the cracking moment increased when coarse recycled aggregates were incorporated, most probably due to thehigher heterogeneity of recycled aggregates.

Conference Proceedings
The Behaviour of GFRP Reinforced Concrete Columns Under Monotonic and Cyclic Axial Compression, Chastre Rodrigues, C., and Silva M. G. , CCC2001, Composites in Construction, Porto, p.245-250, (2001) Abstractchastre_rodrigues2001si_-_ccc2001.pdf

n/a

The behaviour of RC columns retrofitted with FRP or polymeric concrete under axial compression and cyclic horizontal loads, Chastre Rodrigues, C., and Silva M. A. G. , 9th International Conference on Inspection, Appraisal, Repairs and Maintenance of Structures, Oct 20-21, Fuzhou, PEOPLES R CHINA, p.393-400, (2005) Abstract

The seismic retrofit of reinforced concrete columns with FRP jackets has received a considerable increment in recent years due the high strength-weight and stiffness-weight ratios of FRP compared to other materials. The FRP outer shell also contributes to prevent or delay environmental degradation of the concrete and corrosion of the steel reinforcement. An experimental program conducted in order to analyze the behavior of reinforced concrete columns jacketed with FRP composites or repaired with polymeric concrete and subjected to axial compression and cyclic horizontal loads is described. The dimensions of the cylindrical columns were 1500 mm height by 250 mm diameter. The influence of various parameters on the response, including the type of confining material and the number of FRP layers, is reported. The results of the tests are shown and interpreted.

Bond GFRP-Concrete under environmental exposure, Biscaia, H., Silva M. G., and Chastre C. , 15th International Conference on Composite Structures ICCS 15, Porto, (2009) Abstractbiscaia2009sich_-_iccs15.pdf

Fiber reinforced polymers (FRP) are often used to strengthen RC structures.
Despite intense research, durability of reinforced concrete (RC) retrofitted with FRP remains insufficiently known. Long time behavior of the bond laminate-concrete, in flexural strengthening, under environmental action is not well known, conditioning Codes and engineers. An experimental program that subjected RC beams, externally reinforced with Glass FRP (GFRP) strips, to temperature and salt water cycles, for up to 10000h is reported.
At selected intermediate times, the RC beams were loaded to failure in bending. Rupture took place, normally, by tensile failure of concrete at a short distance from the interface with GFRP. The results showed that freeze-thaw cycles were the most severe of the environmental
conditions. The study also generated also non-linear bond-slip relationships from the experimental data. Numerical modeling has been undertaken, based on a commercial code.
The model is based on smeared cracking. Parameters needed for the characterization, namely cohesion and friction angle, were obtained from shear tests conceived for the effect.

Caracterização Experimental e Modelação Numérica da Ligação GFRP/Betão, Biscaia, H., Silva M. G., and Chastre C. , 7º Congresso de Mecânica Experimental, Vila Real, (2008) Abstract
n/a
Comportamento da Ligação CFRP-Resina–Betão Sujeita a Acções Cíclicas, Marques, J. L., Fong P., Macedo P., Chastre Rodrigues C., and Lúcio V. , Betão Estrutural 2004, Porto, (2004) Abstractmarques2004fomachlu_-_be2004.pdf

n/a

Degradação da aderência entre compósitos de GFRP e betão devido a condições ambientais severas, Silva, M. A. G., Biscaia H. C., and Chastre C. , Betão Estrutural 2012, Porto, (2012) Abstractsilva2012bich_-_be2012_-_feup.pdf

A degradação da ligação entre compósitos de matriz polimérica reforçada por fibras (FRP) e o betão é uma das principais causas de possível rotura das vigas e lajes de betão armado reforçadas
externamente por compósitos de FRP. Desde há mais de 10 anos que se estuda, por isso, na UNL o
comportamento dessa ligação, integrado em programa mais alargado de estudo da durabilidade deste tipo de reforço, especialmente quando sujeito a condições ambientais severas que se simulam por processos artificialmente acelerados no laboratório. Em particular a degradação da aderência e o possível descolamento precoce do reforço têm sido modelados física e computacionalmente com principal incidência no uso de fibras de vidro (GFRP) e resina epoxídica. Nesta comunicação mostram-se resultados obtidos em termos de capacidade de carga, força transmitida ao reforço e tensões de aderência após envelhecimentos de pequenas vigas de betão armado (BA) por ciclos de nevoeiro salino, ciclos seco/molhado em solução salina, ciclos de temperatura entre +7,5ºC e +47,5ºC e gelo-degelo de -10ºC a +30ºC. Faz-se recomendação quanto à extensão máxima para diferentes envelhecimentos. Apresenta-se comparação entre resultados de modelação numérica e experimental.

Displacement Estimation of a RC beam test based on TSS algorithm, Almeida, G., Biscaia H., Chastre C., Fonseca J., and Melício F. , CISTI'2010 - 5ª Conferencia Ibérica de Sistemas y Tecnologías de Información, Santiago de Compostela, (2010) Abstract

The traditional methodology used in civil engineering measurements requires a lot of equipment and a very complex procedure especially if the number of target points increase. Since the beginning of the current century, several studies have been conducted in the area of photogrametry using digital image
correlation associated with block motion algorithms to estimate displacements in reinforced concrete (RC) beams during a load test. Using image processing techniques it is possible to measure the whole area of interest and not only a few points of the tests materials. In this paper, block-matching algorithms are used in order to compare the results from photogrametry techniques and the data obtained with linear voltage displacement transducer (LVDT) sensors during the load tests of RC beams, which are very common to find in civil engineering laboratories.

Estudo do comportamento à compressão de compósitos de madeira e cimento, Faria, G., Lúcio V., Chastre C., and Nunes A. , Encontro Nacional Betão Estrutural 2010, Lisboa, (2010) Abstract
n/a
Factores que influenciam o desempenho da ligação GFRP/betão, Lucas, D., Biscaia H. C., Silva M. A. G., and Chastre C. , Betão Estrutural 2012, Porto, (2012) Abstractlucas2012bisich_-_be2012.pdf

Os compósitos de FRP podem descolar prematuramente da superfíce de betão, isto é, antes de esgotada a sua resistência elástica. Esta situação é mais provável se não forem tidos em conta factores como o tipo de preparação da superfície, a exposição a acção ambiental severa, e a resistência do próprio betão. Com o objectivo de analisar a influência de parte destes factores no desempenho da ligação compósito de fibra de vidro (GFRP) e betão, empreendeu-se uma campanha experimental baseada em ensaios de corte duplo. Os resultados permitiram determinar e comparar as forças máximas transmitidas ao GFRP e tensões de aderência máxima para diferentes tratamentos de superfície e condições de envelhecimento. Foram também determinadas aproximações para curvas de tensão de aderência vs. deslizamento (bond-slip). Os resultados obtidos são contrastados com resultados obtidos por modelação numérica.

Flexural Behaviour of RC T-Beams Strengthened with Different FRP Materials, Carvalho, Tiago, Chastre Carlos, Biscaia Hugo, and Paula Raquel , The Third International fib Congress and Exhibition "Think Globally, Build Locally", , Washington DC, (2010) Abstract

The strengthening of reinforced concrete structures with FRP materials has received a
considerable increment in recent years due to the high strength-weight and stiffness-weight
ratios of FRP compared to other materials.
An experimental programme was conducted in order to analyse the behaviour of different
structural solutions to strengthen reinforced concrete beams with FRP composites (EBR
GFRP, EBR CFRP, NSRM-CFRP) and is described. The RC T beams had a 3m span by 0.3m
height and were tested until rupture in a 4-point bending test system.
The NSMR technique has proved to be the most effective of the three alternatives tested, as it
obtained high strength, combined with high ductility. Nevertheless, all the systems show
great strength increment in relation to the non retrofitted T-beams, proving to be effective
approaches to the flexural strengthening of RC beams.

Influência do Confinamento nos Modelos de Cálculo de Pilares Reforçados com CFRP ou GFRP, Chastre Rodrigues, C., Paula A. R., and Silva M. G. , Betão Estrutural 2000, Porto, (2000) Abstractchastre_rodrigues2000pasi_-_be2000_-_feup.pdf

n/a

Ligação Pilar - Fundação com Armaduras Salientes do Pilar, em Estruturas Pré-Fabricadas, Reguengo, R., Lúcio V., and Chastre C. , 2º Congresso Nacional de Pré-Fabricação em Betão, Lisboa, (2008) Abstractreguengo2008luch_-_2_cnp_-_lnec.pdf

A ligação pilar-fundação tem um papel fundamental no comportamento das estruturas pré-fabricadas, em particular, na presença de acções horizontais, como a acção dos sismos e do vento, que introduzem esforços elevados na base dos pilares. Um dos sistemas de ligação pilar-fundação usados em estruturas pré-fabricadas consiste em deixar na extremidade inferior dos pilares armaduras salientes que são introduzidas em negativos executados nas fundações. Estes negativos são posteriormente injectados com grout para garantir a ligação. No presente trabalho foram estudadas diferentes soluções de negativos para ligação das armaduras do pilar à fundação, tendo sido realizados ensaios monotónicos para analisar o seu comportamento. Nesta comunicação apresentam-se e discutem-se os resultados obtidos da análise experimental efectuada.

Ligação Pilar - Fundação em Estruturas Pré-Fabricadas. Estudo experimental, Reguengo, R., Lúcio V., and Chastre C. , Seminário SILE’08, Lisboa, (2008) Abstract
n/a
Ligação pilar – fundação com armaduras salientes do pilar, em estruturas pré-fabricadas – Ensaios monotónicos e ensaios cíclicos, Reguengo, R., Lúcio V., and Chastre C. , Betão Estrutural 2008, Guimarães, (2008) Abstractreguengo2008luch_-_be2008.pdf

A ligação pilar-fundação tem um papel fundamental no comportamento das estruturas pré-fabricadas,
em particular, na presença de acções horizontais, como a acção dos sismos e do vento. Um dos sistemas de ligação pilar-fundação usados em estruturas pré-fabricadas consiste em deixar na extremidade inferior dos pilares armaduras salientes que são introduzidas em negativos executados nas fundações, sejam elas sapatas ou maciços de encabeçamento de estacas. Estes negativos são posteriormente injectados com “grout” para garantir a ligação. Foram estudados diferentes soluções de negativos para ligação das armaduras do pilar na fundação. Foram realizados ensaios monotónicos e cíclicos, para analisar não só o comportamento às acções estáticas mas também para a acção sísmica. No presente trabalho apresentam-se os resultados obtidos com a análise experimental efectuada. O estudo realizado permite apresentar recomendações para projecto e quais os tipos de ligações com melhor desempenho.