Publications

Export 15 results:
Sort by: Author Title Type [ Year  (Desc)]
2019
Assessment of the influence of gravity load in RC beams’ critical zones subjected to cyclic loading, Gião, Rita, Lúcio Valter, and Chastre Carlos , Proceedings of the fib Symposium 2019: Concrete - Innovations in Materials, Design and Structures, May, 27-29, 2019, Kraków, Poland, p.497-504, (2019) Abstract

The aim of the present paper is to evaluate the gravity loads effect in the behaviour of reinforced concrete beams critical zones subjected to cyclic loads. A numerical study to assess the influence of gravity load on RC beam critical zones subjected to cyclic loading is presented, assuming the level of gravity load as a variable parameter. For this purpose, the non-linear model was previously validated with an experimental campaign carried out on RC beam connection subject to cyclic loading with and without gravity loads. The consideration of the gravity load effects led to an accumulation of negative (hogging) deformation and the formation of an unidirectional plastic hinge. In order to validate this behaviour in an overall structural response, a non-linear numerical analysis of a RC frame system under cyclic loads, subject to different levels of gravity load, is also presented. The numerical results are analysed in terms of global hysterical response, accumulated energy dissipation and equivalent viscous damping ratio. In this numerical study was observed that the hysteretic response depends on the load path. In the presence of higher gravity loads levels, the structure hysteretic behaviour exhibits higher damage levels and the failure mechanism is prone to the formation of four plastic hinges. This phenomenon is analysed and discuss in the present paper. © Federation Internationale du Beton (fib) - International Federation for Structural Concrete, 2019.

Gravity load effects on the behaviour of reinforced concrete beam critical zones subjected to cyclic loads, Gião, Rita, Lúcio Valter, and Chastre Carlos , Engineering Structures, 2019/02/15/, Volume 181, p.503-518, (2019) AbstractWebsite

The aim of the present study was to proceed to a numerical analysis of the gravity load effects on the behaviour of reinforced concrete beam critical zones when subjected to cyclic loads. A parametric study to assess the influence of different levels of gravity load on RC beam critical zones subjected to cyclic loading was carried out. For this purpose, assuming the level of gravity load as a variable parameter, a nonlinear numerical model of a beam-column connection, previously calibrated with experimental data, was used. In order to evaluate the gravity load effects in the global response, a numerical study of a RC frame system is also presented. The numerical results are analysed in terms of global hysteretic response, accumulated energy dissipation and equivalent viscous damping ratio. In this numerical study, it was observed that the hysteretic response depends on the load path. In the presence of higher gravity load levels, the structure hysteretic behaviour exhibits higher damage levels, associated to a failure mechanism corresponding to the formation of four span plastic hinges. Thus, the proper test procedure should involve the imposition of a reverse cyclic displacement history starting each cycle from the gravity load effects.

2017
fib Bulletin 84. Precast Insulated Sandwich Panels, Hughes, Simon, Acker Arnold Van, Chastre Carlos, Gasperi Antonello, Jones George, Karutz Holger, Krohn Jason, Laliberté Diane, Lindstrom Gosta, Ronchetti Alessandra, Sennour Larbi, Seshappa Venkatesh, Sthaladipti Saha, Suika Arto, Tillman Mathias, and Tsoukantas Spyros , fib Bulletin 84, Number fib Bulletin, Lausanne, (2017) Abstract

Precast concrete sandwich panels started being used as cladding for buildings, together with the rise of industrial prefabrication, during the mid-20th century. Since then, society and industry have become increasingly aware of energy efficiency in all fields, for both affordability and sustainability consciousness. As such, buildings have been subject to increasingly stringent requirements with the technology of sandwich panels kept continually at the forefront.
Nowadays, sandwich panels have reached the highest standards of functional performance as structural efficiency, flexibility in use, the speed as well as of aesthetic appeal. These combine in building construction with the well-known advantages of prefabrication; such as construction, quality consciousness, durability and sustainability. Sandwich panels have gained more and more important in their field, thus representing quite a significant application within the industry of prefabrication and an important share of the market.
The Commission ‘Prefabrication’ is keen to promote the development of all precast structural concrete products and to transfer the knowledge to practical design and construction. Now filling a strategic gap, by issuing this Guide to Good Practice, which includes design considerations, structural analysis, building physics, use of materials, manufacturing methods, equipment, field performance, and provides a comprehensive overview of the information currently available worldwide. The Commission is particularly proud that this document is a result of close cooperation with PCI and that it will be published by both fib and PCI. This cooperation started six years ago, first with comparing the different approaches to several issues, then progressively integrating up to producing common documents, like this one, that wasn’t yet treated in a specific Guide by either body.

Cáceres-Florencia, patrimonio vivo: Ensayos técnico-arquitectónicos, Salcedo Hernández, José Carlos, Fortea Luna Manuel, Lauria Antonio, Rovero Luisa, Tonietti Ugo, Chastre Carlos, González Jiménez Luis, Matas Casco Miguel, and Saumell Lladó Juan , Suplementos de Investigación en Construcciones Arquitectónicas , Volume 3, Cáceres, p.156, (2017) Abstract
n/a
Characterisation of unidirectional fibre reinforced grout as a strengthening material for RC structures, Gião, Rita, Lúcio Valter, and Chastre Carlos , Construction and Building Materials, Volume 137, p.272-287, (2017) Abstract

The main goal of the present research work is to characterise a unidirectional fibre reinforced grout (UFRG), developed as an alternative material to strengthen RC structures using small thickness jacketing. A high performance cementitious grout reinforced with continuous and unidirectional non-woven steel fibre mat has been developed for this purpose. It was expected that the optimization of the percentage and alignment of the steel fibres would yield a more efficient fibre grout. In fact, the composite should attain higher tensile strength with continuous fibres since the fibre embedment length is enough to prevent fibre pull-out. An experimental programme was carried out to characterise the UFRG’s mechanical properties. Compressive tests were conducted on small thickness tubular specimens to enable the determination of the compressive strength and the static modulus of elasticity. The tensile strength was obtained from splitting tests performed on cubic specimens (DIN 1048-5). Semi-empirical equations, based on the experimental results, are proposed to estimate UFRG’s modulus of elasticity, compressive strength and tensile strength. Two strengthening solutions for RC structures using small thickness CFRP jacketing are presented.

2016
fib Bulletin 78. Precast-concrete buildings in seismic areas, Tsoukantas, Spyros, Toniolo Giandomenico, Pampanin Stefano, Ghosh S. K., Sennour Larbi, D’Arcy Thomas, Sthaladipti Saha, Menegotto Marco, Özden Şevket, Lúcio Válter, Chastre Carlos, Dritsos Stefanos, Psycharis Ioannis, Topintzis Tryfon, Kremmyda Georgia, Fernández-Ordóñez David, de Chefdebien André, Hughes Simon, and Rajala Lasse , fib bulletin, 2016, Number fib Bulletin 78, Lausanne, p.273, (2016) Abstractfib_bulletin78.jpgWebsite

This document has a broad scope and is not focussed on design issues. Precast construction under seismic conditions is treated as a whole. The main principles of seismic design of different structural systems, their behavior and their construction techniques are presented through rules, construction steps and sequences, procedures, and details that should lead to precast structures built in seismic areas complying with the fundamental performance requirements of collapse prevention and life safety in major earthquakes and limited damage in more frequent earthquakes.The content of this document is largely limited to conventional precast construction and, although some information is provided on the well-known “PRESSS technology” (jointed ductile dry connections), this latter solution is not treated in detail in this document.The general overview, contained in this document, of alternative structural systems and connection solutions available to achieve desired performance levels, intends to provide engineers, architects, clients, and end-users (in general) with a better appreciation of the wide range of applications that modern precast concrete technology can have in various types of construction from industrial to commercial as well as residential. Lastly, the emphasis on practical aspects, from conceptual design to connection detailing, aims to help engineers to move away from the habit of blindly following prescriptive codes in their design, but instead go back to basic principles, in order to achieve a more robust understanding, and thus control, of the seismic behaviour of the structural system as a whole, as well as of its components and individual connections.

2014
Assessing the behaviour of RC beams subject to significant gravity loads under cyclic loads, Gião, Rita, Lúcio Válter, and Chastre Carlos , Engineering Structures, 2//, Volume 59, Number 2, p.512-521, (2014) AbstractWebsite

Gravity loads can affect a reinforced concrete structure’s response to seismic actions, however, traditional procedures for testing the beam behaviour do not take this effect into consideration. An experimental campaign was carried out in order to assess the influence of the gravity load on RC beam connection to the column subjected to cyclic loading. The experiments included the imposition of a conventional quasi-static test protocol based on the imposition of a reverse cyclic displacement history and of an alternative cyclic test procedure starting from the gravity load effects. The test results are presented, compared and analysed in this paper. The imposition of a cyclic test procedure that included the gravity loads effects on the RC beam ends reproduces the demands on the beams’ critical zones more realistically than the traditional procedure. The consideration of the vertical load effects in the test procedure led to an accumulation of negative (hogging) deformation. This phenomenon is sustained with the behaviour of a portal frame system under cyclic loads subject to a significant level of the vertical load, leading to the formation of unidirectional plastic hinges. In addition, the hysteretic behaviour of the RC beam ends tested was simulated numerically using the nonlinear structural analysis software – OpenSees. The beam–column model simulates the global element behaviour very well, as there is a reasonable approximation to the hysteretic loops obtained experimentally.

Surveying of Sandstone Monuments: New and Traditional Methodologies to Assess Viability of Conservation Actions, Chastre, C., Ludovico-Marques M., Saumell J., Guerrero M., and Delgado M. , 40th IAHS Word Congress of Housing. Sustainable Housing Construction., 16-19 December 2, Funchal, Portugal, p.ID 307 (10p), (2014) Abstract40_iahs_chastre_-_ext.abstract.pdf

Sandstone building stones are important in the building elements of Portuguese monuments, particularly in the western and southern regions. Alveolization due to salt crystallization was the most important degradation pattern found in the old sandstone façades of St. Leonardo’s Church, a Portuguese monument built in Atouguia da Baleia village in the Middle Age. Its sandstone façades have a widespread distribution of deep and large alveolization patterns mainly on portals and vaults that appeared as a result of the past and present vicinity of seashore. In this paper a summary of conservation interventions carried out in the past century in St. Leonardo’s Church is presented, as well as a summary of the studies carried out in the last decade. Then the degradation patterns on the sandstone walls of St. Leonard’s Church are shown and finally the evolution of the alveolization occurred on the sandstone walls over the last sixty to seventy years is analysed. Visual inspection of sandstone walls is compared with a survey performed by laser scanning, which seems to be a powerful technology to carry out 3D geometric modelling of the building elements of stone monuments and also the 3D mapping of stone degradation patterns.

2013
Non-linear analytical model of composites based on basalt textile reinforced mortar under uniaxial tension, Larrinaga, Pello, Chastre Carlos, San-José José T., and Garmendia Leire , Composites Part B: Engineering, 12//, Volume 55, p.518-527, (2013) AbstractWebsite

The recent development of inorganic based composites as low-cost materials in reinforced concrete structural strengthening and precast thin-walled components, requires the creation of models that predict the mechanical behaviour of these materials. Textile Reinforced Mortar (TRM) shows complex stress–strain behaviour in tension derived from the heterogeneity of its constituent materials. This complexity is mainly caused by the formation of several cracks in the inorganic matrix. The multiple cracking leads to a decrease in structural stiffness. Due to the severe conditions of the serviceability limit state in structural elements, the prediction of the stress–strain curve is essential for design and calculation purposes. After checking other models, an empirical nonlinear approach, which is based on the crack control expression included in the Eurocode 2, is proposed in this paper. Following this scope, this paper presents an experimental campaign focused on 31 TRM specimens reinforced with four different reinforcing ratios. The results are analysed and satisfactorily contrasted with the presented non-linear approach.

Development of an injectable grout for concrete repair and strengthening, Bras, Ana, Gião Rita, Lúcio Válter, and Chastre Carlos , Cement and Concrete Composites, (2013) AbstractWebsite

This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCE) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35°C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 minutes. In the hardened state, silica fumes increased not only the grout’s porosity but also the grout’s compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 days and beyond.

2012
Estruturas Pré-Moldadas no Mundo. Aplicações e Comportamento Estrutural, Chastre, Carlos, Lúcio Válter, Acker Arnold Van, Crisp Barry, Gutstein Daniela, Saraiva Filipe, Doniak Íria, Krohn Jason, Viegas José Barros, Ferreira Marcelo, Menegotto Marco, el Debs Mounir, Hughes Simon, Tsoukantas Spyros, and Pampanin Stefano , 2012, Brasil, p.320, (2012) AbstractWebsite

A indústria do betão pré fabricado é, por tradição, inovadora, precursora de novas tecnologias e de novos materiais.O processo produtivo de estruturas com elementos pré-fabricados difere significativamente do das estruturas betonadas em obra pelo facto de uma parte, ou a totalidade, dos elementos da estrutura serem produzidos em fábrica, em condições de produção melhoradas em relação às condições da obra, e serem posteriormente transportados para a obra, onde são, finalmente ligados entre si. A produção em fábrica é efectuada em ambiente protegido do Sol e da chuva, com operários fixos e com formação profissional para desenvolverem tarefas com procedimentos normalizados. Consequentemente, os elementos executados em fábrica possuem melhor qualidade, sob vários aspectos, do que as estruturas executadas em obra.Este livro divide-se em duas grandes áreas, numa primeira abordam-se algumas aplicações de estruturas pré-moldadas no mundo e numa segunda parte descreve-se o seu comportamento estrutural face a diferentes acções. Nos primeiros capítulos relata-se a experiência da pré-fabricação em três países de diferentes continentes: o Brasil, Portugal e a Austrália e revelam-se novas oportunidades que poderão surgir para a indústria da pré-fabricação. Nos capítulos seguintes dá-se um especial enfoque à investigação do comportamento das ligações (rígidas e semi-rígidas). Aborda-se o projecto de estruturas de betão pré-fabricado às acções acidentais. E por fim, dedicam-se os últimos capítulos ao comportamento das estruturas pré-fabricadas face às acções sísmicas. Nesta área, o bom desempenho das estruturas e grande parte do conhecimento e da tecnologia actual advém da resposta dada pelos engenheiros, investigadores e construtores aos fenómenos naturais que afectam as nossas construções, como comprova o desempenho das ligações dúcteis resistentes a momentos em edifícios pré fabricados de betão no verdadeiro teste sísmico que foram os sismos de Christchurch de 2010 e 2011.

fib Bulletin 63. Design of precast concrete structures against accidental actions, Acker, Arnold Van, Chastre Carlos, Cholewicky Andrzej, Crisp Barry, Lúcio Válter, Elliott Kim S., Engström Björn, Gasperi Antonello, Suikka Arto, Tsoukantas Spyros, Vambersky Jan, and Vantomme John , fib bulletin, Number 63, Lausanne, p.78, (2012) AbstractWebsite

Since the 1980’s, several buildings throughout the world have been subject to gas explosions, impact by cars or airplanes, or car bomb attacks. In many cases the effect of the impact or explosion has been the failure of a critical structural member at the perimeter of the building. After the failure, the load supported by that member could not be redistributed and part or all of the structure has collapsed in a progressive manner. The phenomenon that occurs when local failure is not confined to the area of initial distress, and spreads horizontally and/or vertically through the structure, is termed progressive collapse.

Progressive collapse is a relatively rare event, as it requires both an accidental action to cause local damage and a structure that lacks adequate continuity, ductility, and redundancy to prevent the spread of damage. It is technically very difficult and economically prohibitive to design buildings for absolute safety. However it is possible to construct precast concrete buildings that afford an acceptable degree of safety with regard to accidental actions.

A structure is normally designed to respond properly, without damage, under normal load conditions, but local and/or global damages cannot be avoided under the effect of an unexpected, but moderate degree of accidental overload. Properly designed and constructed structures usually possess reasonable probability not to collapse catastrophically under such loads, depending on different factors, for example: the type of loading; the degree and the location of accidental loading in regard to the structure and its structural members; the type of structural system, the construction technology, and the spans between structural vertical members, etc.

No structure can be expected to be totally resistant to actions arising from an unexpected and extreme cause, but it should not be damaged to an extent that is disproportionate to the original cause.

The aim of fib Bulletin 63 is to summarize the present knowledge on the subject and to provide guidance for the design of precast structures against progressive collapse. This is addressed in terms of (a) the classification of the actions, (b) their effect on the structural types, (c) the strategies to cope with such actions, (d) the design methods and (e) some typical detailing, all supplemented with illustrations from around the world, and some model calculations.

Seismic Strengthening of RC Beam-Column Connections, Gião, R., Lúcio V., and Chastre C. , 15th World Conference on Earthquake Engineering, Lisbon, (2012) Abstract

n/a

UFRG – Unidirectional fibre reinforced grout as strengthening material for reinforced concrete structures, Gião, R., Lúcio V., Chastre C., and Bras A. , BEFIB2012 – Fibre reinforced concrete, Guimarães, (2012) Abstract

The present study is part of an extensive research project, where the main objective is to evaluate a strengthening solution for reinforced concrete structures using a small thickness jacketing in the compression side of the RC element with unidirectional fiber reinforced grout - UFRG.
For this purpose a high performance cementitious grout reinforced with continuous and unidirectional non woven fibermat has been developed. It was expected that the use of these type of fibers allowed an optimization of its percentage and orientation. It was expected that the use of these type of fibers allowed an optimization of its percentage and orientation. Besides, for continuous fibers (with an aspect ratio, defined as the length-to-diameter ratio, l/d=∞), the composite should attain higher tensile strength since the fiber embedment length is enough to prevent fiber pullout.
The experimental campaign included a set of preliminary tests that allowed the design of the fiber reinforced grout, sustained with rheological parameters [7] and mechanical characterization tests of the materials.
Finally, an experimental campaign was carried out in order to proceed to the mechanical characterization of the unidirectional fiber reinforced grout. Compressive tests were conducted in small thickness tubular specimens that enable the determination of the compressive strength and the static modulus of elasticity of the material. The tensile strength of the material was obtained using splitting tests of cubic specimens (according the standard DIN 1048-5). The experimental results are presented and analyzed.

2009
New Methodology For Reinforced Concrete Beam-Column Cyclic Test, Gião, Rita, Lúcio Valter, Chastre Carlos, and Proença Jorge , International FIB Conference "Concrete - 21st Century Superhero, London, (2009) Abstract

The aim of the present communication is to present an analysis of the gravity load influence on the hysteretic behaviour of a beam-column connection. For this purpose, in the experimental campaign a new procedure for RC cyclic tests is presented in order to reproduce closer demands on the beam critical zone than the traditional procedures. The Experimental campaign included cyclic tests of the specimens according with the ECCS recommendation and an innovate procedure. The test results are presented, compared and analysed. A numerical simulation of the tests is presented where the model for the hysteretic response of the beam was calibrated with the experimental results. Finally, the behaviour of a portal frame system under cyclic displacements up to a drift of 3.5% was analysed, assuming that the non-linearity is concentrated on the plastic hinges, considering different levels of gravity load. Thus it is intended to assess the influence of the gravity load on the behaviour of a structure subjected to cyclic loads.