reinforced concrete columns

Showing results in 'Publications'. Show all posts
Damage Effect on Concrete Columns Confined with Carbon Composites, Faustino, Pedro, and Chastre Carlos , ACI Structural Journal, Volume 113, Number 4, (2016) AbstractWebsite

Five experimental cyclic tests were carried out on reinforced concrete rectangular columns with rounded corners, different condition (new and damaged) and different strengthening systems: that included confinement through carbon fiber (CFRP) jackets, anchor dowels, high strength repair mortar and external longitudinal stainless steel bars. Lateral load - displacement relationship, energy dissipation, ductility and curvature results were analyzed together with two different damage assessment classifications. The overall evaluation concludes that the use of external confinement with CFRP on RC columns is viable and of effective performance enhancement alone and combined with other techniques. Damaged columns that were retrofitted showed an increased load capacity up to 20% along with good ductile behavior within the limits of the US, European, Canadian and Japanese codes, with minor/moderate degree of damage at 1% drift ratio and moderate degree of damage at 2% drift ratio.

Lateral cyclic behaviour of RC columns confined with carbon fibres, Faustino, Pedro, Frade Pedro, and Chastre Carlos , Structures, February 2016, Volume 5, p.196-206, (2016) AbstractWebsite

Reinforced concrete (RC) columns with various strengthening systems and different conditions were tested to cyclic lateral and axial loading for the purpose of performance assessment. Tests included confinement strengthening with carbon-fiber-reinforced polymer (CFRP) sheets, longitudinal strengthening with CFRP laminates and confining CFRP jacket, longitudinal strengthening with stainless steel bars and confining CFRP jacket, tested column until reinforcing steel failure, repair and CFRP confining jacket, and longitudinal strengthening with stainless steel bars. The analysis of the tests results as to load-displacement relationship and energy dissipation led to the conclusion that the use of external longitudinal strengthening with CFRP confinement is effective for performance retrofitting and upgrading, and viable in terms of execution. The load capacity increase due to strengthening reached 36–46% with good ductile behaviour. Nonlinear numerical modelling was carried out using two approaches which represent reasonably well the global performance of the studied columns for the prediction of the ascending load-displacement relationship and the peak load values in each cycle.