Debonding
Mechanical Response of Anchored FRP bonded joints: A Nonlinear Analytical Approach,
Biscaia, Hugo, Chastre Carlos, Silva Cinderela, and Franco Noel
, Mechanics of Advanced Materials and Structures, (2018)
AbstractThe paper presents a nonlinear analytical solution for the prediction of the full-range debonding response of mechanically-anchored FRP composites from the substrate. The nonlinear analytical approach predicts, for any monotonic loading history or bonded length the relative displacements (or slips) between materials, the strains in the FRP composite, the bond stresses within the interface and the stresses developed in the substrate. The load-slip responses FRP-to-substrate interfaces with a short and a long bonded lengths are motive of analysis and discussion. The solutions obtained from the proposed approach are also compared with other experimental results found in the literature.
Experimental evaluation of bonding between CFRP laminates and different structural materials,
Biscaia, Hugo, Chastre Carlos, Borba Isabel, Silva Cinderela, and Cruz David
, Journal of Composites for Construction, Volume 20, Number 3, p.04015070, (2016)
AbstractThis study presents an analysis of Carbon Fiber Reinforced Polymers (CFRP)-to-parent material interfaces based on 40 single-lap shear tests intended to highlight the strength of the interfaces under fracture mode II. Three different substrates are analyzed: timber;concrete and steel, using the same CFRP laminates and adhesive agent. The Externally Bonded Reinforcement (EBR) technique was used throughout the study. The results show that the CFRP-to-timber interfaces had the highest strength but also showed that these interfaces need a longer bonded length in order to reach maximum strength, i.e., CFRP-to-timber interfaces had the longest effective bond length. The local non-linear bond-slip curve of CFRP-to-concrete can be approximated to exponential curves, whereas the CFRP-to-timber or steel interfaces showed tri-linear and bi-linear bond-slip relations, respectively. Also, the CFRP-to-timber interfaces revealed the highest fracture energy.
Factors influencing the performance of externally bonded reinforcement systems of GFRP-to-concrete interfaces,
Biscaia, Hugo C., Silva Manuel A. G., and Chastre Carlos
, Materials and Structures, 2014/06/29, Volume 48, Issue 9, p.2961-2981, (2015)
AbstractFibre reinforced polymer (FRP) composites may prematurely debond from the surface of concrete, i.e. before its elastic resistance is exhausted. This is a very common situation and can be aggravated if additional factors are not taken into account. These factors include the type of surface preparation, the exposure to aggressive environmental action, the tensile concrete strength or fatigue and creep loading to which the structural element may be subject. An experimental programme based on double shear tests was undertaken to analyse the influence of some of these factors on the performance of the interface between composite glass fibres (GFRP) and concrete. The results allowed the determination and comparison of maximum loads transmitted to the GFRP plates and maximum bond stresses obtained considering various surface treatments and aging conditions. Bond–slip curves were also determined. The experimental results are compared with those obtained from a numerical analysis.
Numerical modelling of the effects of elevated service temperatures on the debonding process of frp-to-concrete bonded joints,
Biscaia, Hugo C., Chastre Carlos, Viegas André, and Franco Noel
, Composites Part B: Engineering, Volume 70, p.64-79, (2015)
AbstractThere are many issues concerning the performance behaviour of FRP-to-concrete interfaces at elevated service temperatures (EST). At EST, i.e. slightly above the glass transition temperature (Tg), some properties associated with the FRP composites, such as the stiffness, strength or the bond characteristics, degrade. This is a crucial issue and there are only a few studies that take into account such effects on FRP-to-concrete interfaces at EST. This paper examines, through a numerical analysis, the performance of FRP-to-concrete bonded joints at EST using a new discrete model based on truss elements and shear springs. The External Bonded Reinforcement (EBR) systems subjected to EST are analyzed. The numerical discrete model was implemented in a MATLAB routine and the bond-slip curves of the interfaces at EST were obtained from a model found in literature. The numerical results revealed that the interface at EST behaves similarly to one with two equal mechanical loads applied at both ends of the FRP plate. The load-slip curves or bond stresses, strains or slippages along the bonded length obtained from several bond-slip curves at different temperatures were obtained. Two different single-lap shear tests were simulated at steady-state (steady temperature followed by load increase) and transient state (steady load followed by temperature increase). Regarding the influence of the temperature on the adhesion between the FRP and concrete, the results showed that an increase in the temperature at an earlier situation, i.e. during a period where temperature had no influence in the concrete deformations, leads to an increase in the effective bond length of the interface affecting the initial strength of the interface.
Bond-slip model for FRP-to-concrete bonded joints under external compression,
Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G.
, Composites Part B: Engineering, 10//, Volume 80, p.246-259, (2015)
AbstractThe influence of compressive stresses exerted on FRP-concrete joints created by external strengthening of structural members on the performance of the system requires better understanding especially when mechanical devices are used to anchor the externally bonded reinforcement (EBR). The numerical modelling of those systems is a tool that permits insight into the performance of the corresponding interfaces and was used in the present study, essentially directed to analyse the effectiveness of EBR systems under compressive stresses normal to the composite surface applied to GFRP-to-concrete interfaces. The compressive stresses imposed on the GFRP-to-concrete interface model the effect produced by a mechanical anchorage system applied to the EBR system. An experimental program is described on which double-lap shear tests were performed that created normal stresses externally applied on the GFRP plates. A corresponding bond-slip model is proposed and the results of its introduction in the numerical analysis based in an available 3D finite element code are displayed, showing satisfactory agreement with the experimental data. The results also showed that lateral compressive stresses tend to increase the maximum bond stress of the interface and also originate a residual bond stress which has significant influence on the interface strength. Also, the strength of the interface increases with the increase of the bonded length which have consequences on the definition of the effective bond length.
Numerical analysis of FRP anchorage zones with variable width,
Biscaia, Hugo C., Micaelo Rui, Teixeira João, and Chastre Carlos
, Composites Part B: Engineering, 11//, Volume 67, p.410-426, (2014)
AbstractThe use of Fibre Reinforced Polymers (FRP) has recently become widespread in the construction industry. However, some drawbacks related to premature debonding of the FRP composites from the bonded substrates have been identified. One of the solutions proposed is the implementation of mechanical anchorage systems. Although some design guidelines have been developed, the actual knowledge continues to be rather limited. Thus, designers and researchers have not yet achieved any consensus on the efficiency of any particular anchor device in delaying or preventing the premature debonding failure mode that can occur in Externally Bonded Reinforcement (EBR) systems. This paper studies the debonding phenomenon of FRP anchoring systems with a linear variable width, with a numerical analysis based on the Distinct Element Method (DEM). Combined systems with constant and variable width are also discussed. The FRP-to-parent material interfaces are modelled with a rigid-linear softening bond–slip law. The numerical results showed that it is possible to attain the FRP rupture force with a variable width solution. This solution is particularly attractive when the bonded length is shorter than the effective bonded length because the strength of the interface can be highly incremented.
Linear and nonlinear analysis of bond-slip models for interfaces between FRP composites and concrete,
Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G.
, Composites Part B: Engineering, Volume 45, Number 1, p.1554-1568, (2013)
AbstractThe paper analyses different analytical and numerical solutions for the debonding process of the FRP-to-concrete interface on shear tests with the FRP plate submitted to a tensile load in one of its ends. From the point of view of the state of the art, two different ways of finding the bond-slip curve from experiments are discussed and analysed. Essentially, three different linear bond-slip models, one exponential model and another power based function are employed in the numerical process. The results are analysed and compared. The differences found in the stress field along the interface, maximum load, maximum slip, ultimate slip, fracture energy and effective bond length are reported. The load-slip behaviour is also presented for the linear and non-linear models herein studied and the influence of the local bond-slip model on the debonding process is discussed. The numerical integration process used on the present study proved to be coherent with the analytical expressions determined for the linear bond-slip models and allowed to verify that maximum load transmittable to the FRP plate is influenced by the square root of the FRP stiffness and fracture energy even when nonlinear bond-slip models are assumed.
Nonlinear numerical analysis of the debonding failure process of FRP-to-concrete interfaces,
Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G.
, Composites Part B: Engineering, Volume 50, p.210-223, (2013)
AbstractThe paper analyses numerical solutions for the process leading to debonding failure of fiber reinforced polymers (FRP)-to-concrete interfaces in shear tests with the FRP plate subjected to a tensile load at one end. Any realistic local nonlinear bond-slip law can be used in the numerical analysis proposed in the present study. However, only a Popovics’ type expression is employed in the numerical process due to its use in different studies found in the literature. Effective bond length (Leff) is discussed and an expression depending on the Popovics’ constant (nP) is proposed to calculate it. Assuming a fracture in pure Mode II, the debonding process is analyzed in detail and distributions of bond stresses and strains in the FRP plate along the interface are presented. The load-displacement behaviour is also presented and the influence of the local bond-slip law on the debonding process is discussed.