O Portal do docente é uma ferramenta de apoio que permite a cada Professor da FCT NOVA criar autonomamente a sua página pessoal e aí inserir o seu curriculum, divulgar artigos científicos, apresentar as disciplinas leccionadas, partilhar feeds, etc.
In this work, we obtained a charge state distribution inside an Ar plasma produced by an electron–cyclotron-resonance ion source. The processes that lead to the observed lines in x-ray spectra are identified and included in the simulated x-ray spectrum. The geometrical constraints of the flat double crystal spectrometer, used to measure the x-ray spectrum, are investigated as they are crucial for correctly obtaining the ion densities from the observed transition amplitudes. Multiple electron impact ionization is included, and a realistic electron velocity distribution is taken into account. The charge state distribution of the Ar ions is compared to measured extracted ionic currents.
Ana, Baptista, Ferreira Isabel, and Borges João Paulo. "Cellulose-Based Bioelectronic Devices." Cellulose: Medical, Pharmaceutical and Electronic Applications. Eds. Theo van de Ven, and Louis Godbout. INTECH, 2013. 67-82. Abstract
In this work, we obtained a charge state distribution inside an Ar plasma produced by an electron–cyclotron-resonance ion source. The processes that lead to the observed lines in x-ray spectra are identified and included in the simulated x-ray spectrum. The geometrical constraints of the flat double crystal spectrometer, used to measure the x-ray spectrum, are investigated as they are crucial for correctly obtaining the ion densities from the observed transition amplitudes. Multiple electron impact ionization is included, and a realistic electron velocity distribution is taken into account. The charge state distribution of the Ar ions is compared to measured extracted ionic currents.
{Aluminophosphate glasses belonging to the Li2O-BaO-Al 2O3- La2O3-P2O 5 system doped with Tb3+ were prepared and investigated. Methods as Induced Coupled Plasma-Mass Spectrometry (ICP-MS), Induced Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) and X-ray diffraction (XRD) have been used to establish the elemental composition of these vitreous materials. The influence of the Tb3+ ions on the optical properties of the phosphate glasses has been investigated in relation with the structural characteristics of the vitreous matrix. The optical behavior has been studied by ultra-violet-visible (UV-Vis) spectroscopy, revealing electronic transitions specific for terbium ions. Fluorescence spectroscopy measurements have been performed by excitation in the UV and visible domains (377 nm and 488 nm) which resulted in the most significant fluorescence peaks in the Vis domain (540 and 547 nm). Structural information via vibration modes were provided by Fourier Transform Infrared (FTIR) absorption spectra in the 400-4000 cm-1 range. Absorption peaks specific for the vitreous phosphate matrix were put in evidence as P-O-P symmetrical and asymmetrical stretching vibration modes, P-O-P bend, PO2- symmetrical and asymmetrical stretching vibration modes
The use of a vacuum double crystal spectrometer, coupled to an electron-cyclotron resonance ion source (ECRIS), allows to measure low-energy x-ray transitions energies in highly-charged ions with accuracies of the order of a few parts per million. We have used this installation to measure the 1s2p 1 P1 - 1s2 1 S0 diagram line and the 1s2s 3 S1 - 1s2 1 S0 forbidden M1 transition energies in helium-like argon, the 1s2s2p 2 P j 1s2 2s 2 S1/2 transitions in lithium-like argon and the 1s2s2 2p 1 P1 - 1s2 2s2 1 S0 transition in beryllium-like argon. These transition measurements have accuracies between 2 and 4 ppm depending on the line intensity. Thanks to the excellent agreement between the simulations and the measurements, we were also able to measure the transition width of all the allowed transitions. The results are compared to recent QED and relativistic many-body calculations.