Publications

Export 46 results:
Sort by: Author Title Type [ Year  (Desc)]
2008
Neagu, E. R., R. M. Neagu, C. J. Dias, M. C. Lanca, and J. N. Marat-Mendes, "The determination of the metal-dielectric interface barrier height from the open-circuit isothermal charging current", Journal of Applied Physics, vol. 104, no. 3, 2008. AbstractWebsite

There is a sustained interest both from theoretical and from practical points of view to understand the isothermal charging and the isothermal discharging currents in dielectrics. The measured currents are analyzed either in terms of polarization mechanisms or in terms of charge injection/extraction at the metal-dielectric interface and the conduction current through the dielectric material. As long as we do not know the nature of the origin of the current, it is not clear what information we can get by analyzing the experimental data. We propose to measure the open-circuit isothermal charging and discharging currents just to overpass the difficulties related to the analysis of the conduction mechanisms in dielectric materials. We demonstrate that besides a polarization current, there is a current related with charge injection or extraction at the metal-dielectric contact and a reverse current related to the charge trapped into the superficial trap states of the dielectric and that can jump at the interface in a reverse way. An analytical expression for the current is proposed. By fitting the experimental data to this analytical equation, two important parameters can be determined: (i) the highest value of the relaxation time for the polarization mechanisms still involved into the transient current and (ii) the height of the potential barrier W-0 at the metal-dielectric interface at the initial time when the step voltage is applied. The value obtained for Al-polyethylene terephthalate interface is (0.43 +/- 0.02) eV. For a charging voltage of 220 V there are 6x10(14) trapped electrons/m(2). (c) 2008 American Institute of Physics.

Neagu, E. R., R. M. Neagu, C. J. Dias, C. M. Lanca, and J. N. Marat-Mendes, "The determination of the metal-dielectric interface barrier height from the open-circuit isothermal charging current", Journal of Applied Physics, vol. 104, no. 3, 2008. Abstract
n/a
2007
Lanca, M. C., M. Fu, E. Neagu, L. A. Dissado, J. Marat-Mendes, A. Tzimas, and S. Zadeh, "Space charge analysis of electrotherinally aged XLPE cable insulation", Journal of Non-Crystalline Solids, vol. 353, no. 47-51, pp. 4462-4466, 2007. AbstractWebsite

Cross-linked polyethylene (XLPE) is currently widely used as an insulating material for power cables due to its good physical properties, however when in use it undergoes an electrical ageing process. Its ability to trap electric charge can give rise to space charge accumulation in the bulk of the polymer and produce localised electric stresses that can lead to cable failure, since the electric field will be increased above the design stress in some regions favouring the initiation of degradation there. In this work the PEA (pulsed electro-acoustic) method was used to compare the charge dynamics in three samples (XLPE cable peelings) aged in different ways (electrothermally in the laboratory, field aged in service and thermally aged in the laboratory). Very different transient behavior was found depending upon the ageing history. This is related to differences in the migration of chemical species in the insulation layer, which are known to act as charge traps. All materials showed heterocharge peaks when the space charge reached stability, the magnitude of which seems to be related to the severity of the ageing. (c) 2007 Elsevier B.V. All rights reserved.

2006
Lanca, M. C., E. R. Neagu, L. A. Dissado, and J. Marat-Mendes, "Space charge studies in XLPE from power cables using combined isothermal ans thermostimulated current measurements", Advanced Materials Forum Iii, Pts 1 and 2, vol. 514-516, pp. 935-939, 2006. Abstract

Cross-linked polyethylene (XLPE) peelings from aged power cables from three different sources were studied using a combined procedure of isothermal and thermo-stimulated current measurements. Different parameters, such as electric field, temperature, charging/discharging times, can be selected in order to make an analysis of the space charge characteristics (such as, relaxation times and activation energies). Three different cables peelings were analyzed: A - electrically aged in the laboratory at high temperature, B - service aged for 18 years and C - thermally aged in the laboratory at high temperature. The results were compared for the different types of samples and also with previous results on laboratory aged and produced films of low-density polyethylene (LDPE) and XLPE.

2005
Lanca, M. C., M. Fu, E. Neagu, L. A. Dissado, J. Marat-Mendes, A. Tzimas, and S. Zadeh, Comparative study of space charge in the polymeric insulation of power cables using PEA, isothermal and non-isothermal currents measurements, , pp. 284-287, 2005. AbstractWebsite

An understanding of space charge build-up in the polymeric insulation of power cables is important in determining how aging occurs and progresses and, also in predicting cable lifetime. In this investigation electric-field induced space charge in peelings from XLPE (cross-linked polyethylene) cables was measured using two different methods: the pulsed electro-acoustic technique (PEA) and the combined procedure of isothermal and non-isothermal charging/discharging currents (FTSDC). These two methods allow the study of space charge in highly insulating materials. Also, since electric fields of different orders of magnitude are applied to the sample in the two methods, it is possible to analyze different characteristics of the space charge traps. Prior to the measurements the samples were subjected to conditioning to remove volatiles. Cable peelings from various brands aged under different conditions (including field aged and thermally aged samples) were studied as received from the manufacturers. Some of the samples have undergone further ageing in AC electric field (50Hz) for 1000h to see the influence of further ageing on space charge build-up. The results for the different types of samples are compared in an attempt to correlate different ageing parameters.

2004
MC, L., N. ER, N. RM, D. CJ, M. - M. JN, and D. - G. DK, "Space charge studies in LDPE using combined isothermal and non-isothermal current measurements", IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, vol. 11: Univ Wales, Univ Nova Lisboa, pp. 25-34, Jan, 2004. Abstract
n/a
Lanca, M. C., and J. Marat-Mendes, "Dielectric breakdown statistics of polyethylene for progressively-censored data", Advanced Materials Forum Ii, vol. 455-456, pp. 602-605, 2004. Abstract

The dielectric breakdown of thin films of low-density polyethylene (LDPE) electrically aged in an aqueous solution of NaCl under an AC electric field was investigated. A two-parameter Weibull function was used for the dielectric breakdown time to failure. The probability of failure for a sample was obtained by the White method for progressively censored data. Samples aged at different temperatures were compared. The results show that initially the samples aged at lower temperature (approximate to25degreesC) are more prone to fail, while those aged at higher temperature (50degreesC) fail at longer times. This was attributed to a competition between oxidation and diffusion.

Lanca, M. C., and J. Marat-Mendes, "Dielectric breakdown statistics of polyethylene for progressively-censored data", Advanced Materials Forum Ii, vol. 455-456, pp. 602-605, 2004. Abstract

The dielectric breakdown of thin films of low-density polyethylene (LDPE) electrically aged in an aqueous solution of NaCl under an AC electric field was investigated. A two-parameter Weibull function was used for the dielectric breakdown time to failure. The probability of failure for a sample was obtained by the White method for progressively censored data. Samples aged at different temperatures were compared. The results show that initially the samples aged at lower temperature (approximate to25degreesC) are more prone to fail, while those aged at higher temperature (50degreesC) fail at longer times. This was attributed to a competition between oxidation and diffusion.

Lanca, M. C., E. R. Neagu, R. M. Neagu, C. J. Dias, J. N. Marat-Mendes, and D. K. Das-Gupta, "Space charge studies in LDPE using combined isothermal and non-isothermal current measurements", Ieee Transactions on Dielectrics and Electrical Insulation, vol. 11, no. 1, pp. 25-34, 2004. AbstractWebsite

Using a recently developed procedure combining isothermal and non-isothermal current measurements space charge trapping and transport in LDPE was successfully studied. Unaged, thermally and electrically aged samples were investigated. The samples were conditioned before each measurement in order to obtain reproducible results. In the non-isothermal measurements appeared a broad peak (40degreesC to 50degreesC) that was possible to decompose into two or three peaks (35, 45 and 65degreesC). At even higher temperature another peak was sometimes present (85degreesC) depending on the prior sample conditioning. The space charge is trapped near the surface in deep traps (maximum depth of approximate to 15 mum). Relaxation times, mobilities and activation energies have been calculated for different charging/discharging conditions. For unaged samples the reproducibility of the results was poor while for the aged polyethylene it was quite good, meaning that aging helps conditioning. In the electrically aged LDPE there is a decrease of conductivity and the broad peak of the non-isothermal spectra shows a slight shift towards higher temperatures when compared with the data found in the thermally aged polymer.

Lanca, M. C., E. R. Neagu, R. M. Neagu, C. J. Dias, J. N. Marat-Mendes, and D. K. Das-Gupta, "Space charge studies in LDPE using combined isothermal and non-isothermal current measurements", Ieee Transactions on Dielectrics and Electrical Insulation, vol. 11, no. 1, pp. 25-34, 2004. AbstractWebsite

Using a recently developed procedure combining isothermal and non-isothermal current measurements space charge trapping and transport in LDPE was successfully studied. Unaged, thermally and electrically aged samples were investigated. The samples were conditioned before each measurement in order to obtain reproducible results. In the non-isothermal measurements appeared a broad peak (40degreesC to 50degreesC) that was possible to decompose into two or three peaks (35, 45 and 65degreesC). At even higher temperature another peak was sometimes present (85degreesC) depending on the prior sample conditioning. The space charge is trapped near the surface in deep traps (maximum depth of approximate to 15 mum). Relaxation times, mobilities and activation energies have been calculated for different charging/discharging conditions. For unaged samples the reproducibility of the results was poor while for the aged polyethylene it was quite good, meaning that aging helps conditioning. In the electrically aged LDPE there is a decrease of conductivity and the broad peak of the non-isothermal spectra shows a slight shift towards higher temperatures when compared with the data found in the thermally aged polymer.

2003
Lanca, M. C., C. J. Dias, D. K. Dasgupta, J. Marat-Mendes, and I. Ieee, Comparative study of dielectric relaxation spectra of electrically and thermally aged low density polyethylene, , pp. 161-164, 2003. AbstractWebsite

Low-density polyethylene (LDPE) films were thermally aged in a sodium chloride aqueous solution at constant temperature (thermal aging). Some of the samples were simultaneously immersed in solution and subjected to an electric AC field (electrical aging). The dielectric relaxation spectra at 30 degreesC in the range of 10(-5) Hz to 10(5) Hz were obtained for unaged and aged samples. For the low frequency (LF) region (10(-5) Hz to 10(-1) Hz) the time domain technique was used. A lock-in amplifier was used for the 10(-1) Hz to 10(1) Hz medium frequency (MF) region. While for the high frequency (HF), 10(-1) Hz to 10(5) Hz, RLC bridge measurements were performed. The main differences can be seen between electrically, thermally aged and unaged LDPE in the HF and LF regions. The LF peak is a broad peak related to localized space charge injection driven by the electric field. For electrically aged samples this peak increases in an earlier stage of electrical aging, decreasing afterwards. While in thermally aged samples the peak amplitude always increases with aging time. Finally the HF shows the beginning of a peak due to the gamma and beta transitions. This peak decreases with aging disappearing for the most aged samples.

Lanca, M. C., C. J. Dias, D. K. Dasgupta, J. Marat-Mendes, and I. Ieee, Comparative study of dielectric relaxation spectra of electrically and thermally aged low density polyethylene, , pp. 161-164, 2003. AbstractWebsite

Low-density polyethylene (LDPE) films were thermally aged in a sodium chloride aqueous solution at constant temperature (thermal aging). Some of the samples were simultaneously immersed in solution and subjected to an electric AC field (electrical aging). The dielectric relaxation spectra at 30 degreesC in the range of 10(-5) Hz to 10(5) Hz were obtained for unaged and aged samples. For the low frequency (LF) region (10(-5) Hz to 10(-1) Hz) the time domain technique was used. A lock-in amplifier was used for the 10(-1) Hz to 10(1) Hz medium frequency (MF) region. While for the high frequency (HF), 10(-1) Hz to 10(5) Hz, RLC bridge measurements were performed. The main differences can be seen between electrically, thermally aged and unaged LDPE in the HF and LF regions. The LF peak is a broad peak related to localized space charge injection driven by the electric field. For electrically aged samples this peak increases in an earlier stage of electrical aging, decreasing afterwards. While in thermally aged samples the peak amplitude always increases with aging time. Finally the HF shows the beginning of a peak due to the gamma and beta transitions. This peak decreases with aging disappearing for the most aged samples.

2002
MC, L., D. CJ, D. G. DK, and M. - M. S. J, "Dielectric properties of electrically aged low density polyethylene", Advanced Materials Forum I, vol. 230-2, no. 230-232, pp. 396-399, Jan, 2002. Abstract
n/a
Lanca, M. C., C. J. Dias, D. K. Dasgupta, and J. Marat-Mendes, "Dielectric properties of electrically aged low density polyethylene", Advanced Materials Forum I, vol. 230-2, pp. 396-399, 2002. Abstract

Low density polyethylene (LDPE) films kept in a sodium chloride aqueous solution, were aged under a high AC electrical field. The films were prepared from press moulding of LDPE pellets with small amounts of antioxidants. The dielectric spectra at 30 degreesC in the range of 10(-5) Hz to 105 Hz were obtained prior and after ageing. Three different experimental techniques were used to obtain the full spectrum. For the low frequency (LF) region (10(-5) Hz to 10(-1) Hz) the time domain technique was used (charge and discharge currents were also measured). The measuring device used for the 10(-1) Hz to 10(1) Hz medium frequency (MF) region was a lock-in amplifier. While for the high frequency (HF), 10(-1) Hz to 10(5) Hz, RLC bridge measurements were performed. Differences can be seen between aged and unaged PE. The region showing less changes with ageing is the MF region where the peak of the unaged samples seems to become less defined with ageing time. This peak is probably due to additives and impurities (such as antioxidants) that will tend to slowly diffuse out with time. The LF peak is a broad peak related to localised space charge injection driven by the electric field. This peak increases in an earlier stage of ageing decreasing afterwards possibly when the polymer becomes more conductive. Finally the HF shows the beginning of a peak due to gamma and beta transitions. The later is related to dipolar rotation of carbonyl groups in amorphous polymer regions, while the former is associated to crankshaft motions in the main polymer chain. This peak decreases with ageing disappearing for the most aged samples. This could also be explained if the sample becomes more conductive.

Lanca, M. C., C. J. Dias, D. K. Dasgupta, and J. Marat-Mendes, "Dielectric properties of electrically aged low density polyethylene", Advanced Materials Forum I, vol. 230-2, pp. 396-399, 2002. Abstract

Low density polyethylene (LDPE) films kept in a sodium chloride aqueous solution, were aged under a high AC electrical field. The films were prepared from press moulding of LDPE pellets with small amounts of antioxidants. The dielectric spectra at 30 degreesC in the range of 10(-5) Hz to 105 Hz were obtained prior and after ageing. Three different experimental techniques were used to obtain the full spectrum. For the low frequency (LF) region (10(-5) Hz to 10(-1) Hz) the time domain technique was used (charge and discharge currents were also measured). The measuring device used for the 10(-1) Hz to 10(1) Hz medium frequency (MF) region was a lock-in amplifier. While for the high frequency (HF), 10(-1) Hz to 10(5) Hz, RLC bridge measurements were performed. Differences can be seen between aged and unaged PE. The region showing less changes with ageing is the MF region where the peak of the unaged samples seems to become less defined with ageing time. This peak is probably due to additives and impurities (such as antioxidants) that will tend to slowly diffuse out with time. The LF peak is a broad peak related to localised space charge injection driven by the electric field. This peak increases in an earlier stage of ageing decreasing afterwards possibly when the polymer becomes more conductive. Finally the HF shows the beginning of a peak due to gamma and beta transitions. The later is related to dipolar rotation of carbonyl groups in amorphous polymer regions, while the former is associated to crankshaft motions in the main polymer chain. This peak decreases with ageing disappearing for the most aged samples. This could also be explained if the sample becomes more conductive.

2001
Lanca, M. C., J. N. Marat-Mendes, and L. A. Dissado, "The fractal analysis of water trees - An estimate of the fractal dimension", Ieee Transactions on Dielectrics and Electrical Insulation, vol. 8, no. 5, pp. 838-844, 2001. AbstractWebsite

Water trees result from ac electrical aging of the polymeric insulation of medium and HV power cables in a humid or wet environment. As suggested by their name, they arise from penetration of water in the polymer. Visual observation with the help of an optical microscope shows tree (bush) type structures. This suggests that water trees might be fractal objects. Calculation of the fractal dimension from experimental samples may confirm the fractal characteristics and also give information on the damage caused to the polymer. In this work images of water trees taken under the optical microscope, dyed by methylene blue and etched for scanning electron microscopy (SEM), were studied in order to estimate the fractal dimension using a box-counting algorithm. The photographs, made using an optical microscope (scale of 100 mum), of the dyed samples were obtained from laboratory-aged low-density polyethylene (LDPE) specimens using accelerated techniques. Different field amplitude and frequency and also time of aging were used and the dimension values were compared. SEM images resulting from aged cross-linked polyethylene (XLPE) cables revealed a structure at a different scale (similar to 3 mum). Each photograph was analyzed to compare regions with and without water trees.

Lanca, M. C., J. N. Marat-Mendes, and L. A. Dissado, "The fractal analysis of water trees - An estimate of the fractal dimension", Ieee Transactions on Dielectrics and Electrical Insulation, vol. 8, no. 5, pp. 838-844, 2001. AbstractWebsite

Water trees result from ac electrical aging of the polymeric insulation of medium and HV power cables in a humid or wet environment. As suggested by their name, they arise from penetration of water in the polymer. Visual observation with the help of an optical microscope shows tree (bush) type structures. This suggests that water trees might be fractal objects. Calculation of the fractal dimension from experimental samples may confirm the fractal characteristics and also give information on the damage caused to the polymer. In this work images of water trees taken under the optical microscope, dyed by methylene blue and etched for scanning electron microscopy (SEM), were studied in order to estimate the fractal dimension using a box-counting algorithm. The photographs, made using an optical microscope (scale of 100 mum), of the dyed samples were obtained from laboratory-aged low-density polyethylene (LDPE) specimens using accelerated techniques. Different field amplitude and frequency and also time of aging were used and the dimension values were compared. SEM images resulting from aged cross-linked polyethylene (XLPE) cables revealed a structure at a different scale (similar to 3 mum). Each photograph was analyzed to compare regions with and without water trees.

1995
Lanca, M. C., J. Domingues, and I. Franco, Study of fractal properties in Lichtenberg figures, , pp. 133-144, 1995. AbstractWebsite
n/a
Lanca, M. C., J. Domingues, and I. Franco, Study of fractal properties in Lichtenberg figures, , pp. 133-144, 1995. AbstractWebsite
n/a
1990
Freitas, M. C., M. C. Lanca, A. M. Carvalho, and F. Decorte, "CODES TO COMPUTE RELEVANT GAMMA-GAMMA AND GAMMA-X TRUE-COINCIDENCE LINES IN ABSOLUTE COUNTING OF GAMMA-RAYS WITH A LEPD", Biological Trace Element Research, vol. 26-7, pp. 33-41, 1990. AbstractWebsite
n/a
Freitas, M. C., M. C. Lanca, A. M. Carvalho, and F. Decorte, "CODES TO COMPUTE RELEVANT GAMMA-GAMMA AND GAMMA-X TRUE-COINCIDENCE LINES IN ABSOLUTE COUNTING OF GAMMA-RAYS WITH A LEPD", Biological Trace Element Research, vol. 26-7, pp. 33-41, 1990. AbstractWebsite
n/a