Publications

Export 41 results:
Sort by: Author Title Type [ Year  (Asc)]
1994
Mendes, B. S., M. J. Nascimento, M. I. Pereira, G. Bailey, N. Lapa, J. Morais, and J. F. Santos Oliveira. "Ecoclimatic influence on waste stabilization ponds (WSP) efficiencies: the case study of the Sesimbra system." Water Science and Technology. 30.8 (1994): 269-279. AbstractWebsite

Portugal has a great diversity of ecoclimatic areas and Sesimbra was chosen to carry out a study on WSP efficiencies over five years (1989 to 1993). According to Pina Manique & Albuquerque (1954), the climate is classified as Atlantic Mediterranean (AM). Some environmental and climatic parameters have been studied in order to define the area. The treatment system at Sesimbra has three ponds: anaerobic, facultative and maturation. The physical and chemical parameters studied in the WSP system were: Temperature, pH, Dissolved Oxygen, Conductivity, BOD5, COD, nitrates, nitrites, ammonia and total nitrogen, total and volatile suspended solids, total phosphorus and orthophosphates. Algal populations and the following microbiological parameters were studied: total and fecal coliforms, fecal Streptococci, Clostridium perfringens, Pseudomonas aeruginosa and some Enterobacteriaceae. The K and K20 kinetic parameters were studied and derived for the three ponds utilizing the seasonal regional characteristics from the surrounding area. These values were then correlated with temperature and the subsequent removal efficiencies for each pond deduced. The data obtained indicate a necessity to determine the seasonal fluctuations of the K and K20 kinetic parameters for the WSP systems.

Lapa, N., J. Morais, and J. F. Santos Oliveira. "Valorização de lamas de ETAR’s como fertilizantes dos solos." Indústria e Ambiente. 2 (1994): 4-10.
1995
Mendes, B. S., M. J. Nascimento, M. I. Pereira, G. Bailey, N. Lapa, J. Morais, and J. F. Santos Oliveira. "Efficiency of removal in stabilization ponds. I - Influence of climate." Water Science and Technology. 31.12 (1995): 219-229. AbstractWebsite

Owing to the existing or predictable water deficiencies in the South of Portugal, it is necessary to carry out the appropriate management of water resources, by reducing and/or minimizing the negative impacts of untreated/treated domestic effluents in the aquatic environment. As Portugal has a great diversity of ecoclimatic areas, five different stabilization pond systems were chosen to carry out a control study during one year (from March 1991 to March 1992). According to Pina Manique & Albuquerque the ecological classification of these stations is different, varying from Ibero-mediterranean (continental) up to mediterranean (maritime). The physical and chemical parameters studied were: temperature, pH, dissolved oxygen, conductivity, BOD, COD, nitrates, nitrites, ammonia and total nitrogen, total suspended and volatile solids, total phosphorus and orthophosphates. The microbiological parameters studied were: total and faecal coliforms, faecal Streptococci, Clostridium perfringens and Pseudomonas aeruginosa. The correlations between climatic parameters and the efficiency of the removal of organic matter were analysed.

Mendes, B. S., M. J. Nascimento, M. I. Pereira, G. Bailey, N. Lapa, J. Morais, and J. F. Santos Oliveira. "Efficiency of removal in stabilization ponds. II - Statistical analysis of K values." Water Science and Technology. 31.12 (1995): 231-238. AbstractWebsite

The analytical values obtained from five WSP systems located in different ecoclimatic zones in the centre and South of Portugal, were subjected to a statistical analysis of K and K20 values (as used in the van Hoff-Arrhenius equation) utilizing an analysis of variance and a vectorial analysis of principal components. Significant differences between K and K20 values in facultative, maturation ponds and in the whole system were verified. The projection of the first principal components of eigenvectors made possible the classification of the stations, showing the existence of similarities and discrepancies in their removal BOD kinetics behaviour. The K20 value must be estimated and taken into account for the design of waste stabilization ponds.

Lapa, N., J. Morais, and J. F. Santos Oliveira. "A qualidade de vida em Portugal." Indústria e Ambiente. 5 (1995): 15-24.
Guerrero, C., J. Carrasco de Brito, N. Lapa, and J. F. Santos Oliveira. "Re-use of industrial orange wastes as organic fertilizers." Bioresource Technology. 53.1 (1995): 43-51. AbstractWebsite

The aim of this study was to evaluate the possibility of the re-use of industrial orange wastes as organic soil fertilizer. The assay was performed with a lettuce variety widely produced and consumed in Portugal and, consequently, with great commercial interest. Lactuca sativa L. (osteolata variety) was cultivated in Mitcherlich pots containing samples of a poor soil of the Algarve region. This soil was prepared with different amounts of either pulp or peel orange-wastes from an orange-juice industry. The wastes were applied according to an increasing amount of nitrogen. The results obtained were submitted to statistical tests, in order to find the relations between the production of fresh and dry matter, and the percentages of nutrients (nitrogen, phosphorous, potassium, calcium, magnesium and iron) that were obtained in the dry matter, with the types and amounts of wastes applied. An increase in the average production of both fresh- and dry-matter with increasing amounts of either pulp or peel wastes applied, and high positive correlation coefficients between the average percentages of nitrogen, phosphorus and potassium obtained in the dry matter with the average production of both fresh- and dry-matter were found. No phytotoxicity was observed.

1998
Mendes, B., P. Urbano, C. Alves, J. Morais, N. Lapa, and J. F. Oliveira. "Fungi as environmental microbiological indicators." Water Science and Technology. 38.12 (1998): 155-162. AbstractWebsite

An evaluation of the mycological quality of the sand beaches of the Lisboa and Vale do Tejo coastal area in Portugal was undertaken in May-October 1994. The keratinolytic fungi, yeasts, potential pathogenic and allergic and/or environmental saprophytic fungi were analysed. The results for the yeast Candida were evaluated according to the “Proposed Guidelines for the Microbiological Quality of Sand” (Mendes et al., 1993). The data showed good/satisfactory quality of the sand beaches for the genus Candida. The results indicate that the allergic and/or environmental saprophytic fungi were the most common in sand beaches. The fungi Scopulariopsis and the yeast Candida could be used as specific indicator organisms of sand beaches quality. A new quality objective is introduced that will contribute to improve the sand beaches quality.

1999
Santos Oliveira, J. F., N. Lapa, and J. Morais Eutrofização: a flor da água. Lisboa: IPQ/EPAL, 1999.Website
2002
Lapa, N., J. F. Santos Oliveira, S. L. Camacho, and L. J. Circeo. "An ecotoxic risk assessment of residue materials produced by the plasma pyrolysis/vitrification (PP/V) process." Waste Management. 22.3 (2002): 335-342. AbstractWebsite

Plasma is the fourth state of matter, following the three states of solid, liquid and gas. Experience has amply demonstrated that solids exposed to the oxygen-deficient plasma flame are converted to liquid, and liquid exposed to the same flame is converted to gas. A low amount of vitrified solid residue material usually remains at the end of this process. Plasma pyrolysis/vitrification (PP/V) has been demonstrated as a safe, efficient, cost-effective technology for the treatment of wastes, including hazardous wastes. Besides the low amounts of gaseous byproducts that PP/V produces, the solid vitrified residue presents a low leachability of pollutants. Studies have been performed in many countries in order to assess the leachability of chemical substances. But from the results of identified studies, none has reported results on the ecotoxicological properties of the leachates. The aim of this study was to contribute to the assessment of ecotoxic risk of four different vitrified materials. Vitrified samples of contaminated soils, municipal solid wastes, and incinerator bottom ashes were submitted to the European leaching pre-standard test number prEN 12457-2. The leachates were analyzed for 22 chemical parameters. The biological characterization comprised the assessment of bioluminescence inhibition of Photobacterium phosphoreum bacterium, growth inhibition of Pseudokirchneriella subcapitata algae and the germination inhibition of Lactuca sativa vegetable. The chemical and ecotoxicological results were analyzed according to the French proposal of Criteria on the Evaluation Methods of Waste Toxicity (CEMWT) and a Toxicity Classification System (TCS). The chemical and ecotoxicological results indicated a low leachability of pollutants and a low toxicity level of leachates. All samples studied were as below the TCS class 1 level (no significant toxicity observed) and as non-ecotoxic for CEMWT. Therefore, the environmental ecotoxic risk of the analyzed vitrified samples was determined to be very low.

Lapa, N., R. Barbosa, J. Morais, B. Mendes, J. Méhu, and J. Santos Oliveira. "Ecotoxicological assessment of leachates from MSWI bottom ashes." Waste Management. 22.6 (2002): 583-593. AbstractWebsite

In this paper, chemical and ecotoxicological data of leachates from bottom ashes collected in different Municipal Solid Waste Incinerators (MSWI) are shown. The bottom ashes were collected in Belgium (three incinerators—samples B1 to B3), France, Germany, Italy and United Kingdom (one incinerator in each country—samples F1, D1, I1 and UK1, respectively). Both chemical and ecotoxicological characterizations of leachates were done on the framework of the European Directive 91/689/EEC and the European Council Decision 94/904/EC. This work was carried out under the European project called Valomat, which was supported by the European Commission through Brite-Euram III program. Twenty-one inorganic parameters were analyzed. The ecotoxicological assays were done under standard laboratory conditions, using the bacterium Photobacterium phosphoreum, the freshwater alga Pseudokirchneriella subcapitata, the crustacean Daphnia magna and the vegetable Lactuca sativa. Chemical data varied from sample to sample. Similar results were obtained in biological assays. The samples can be classified as ecotoxic/hazardous according to the French proposal for a Criterion and Evaluation Methods of Waste Ecotoxicity (CEMWE) and the German regulation on Hazardous Waste Classification (HWC). However, samples B1, B2, B3 and D1 comply the maximum limits for direct valorization category defined in the French Classification of Bottom Ashes based on their Polluting Potential (CBAPP). Sample B1 presented the lowest level of ecotoxicity, being considered as the most interesting to be used in the development of new materials for civil engineering works.

2003
Lopes, M. H., P. Abelha, N. Lapa, J. S. Oliveira, I. Cabrita, and I. Gulyurtlu. "The behaviour of ashes and heavy metals during the co-combustion of sewage sludges in a fluidised bed." Waste Management. 23.9 (2003): 859-870. AbstractWebsite

Co-combustion tests of dry sewage sludges with coal were performed in a pilot bubbling FBC aiming at the characterization of ashes and determining the behaviour of heavy metals in the process. The tests showed compliance with the regulatory levels as far as heavy metal emissions were concerned. The bottom ashes, which accounted for about 70% of the total ash production, were obtained in a granular form, with diameters ranging from 0.5 to 4 mm. The heavy metals were distributed in ashes obtained from different locations of the installation and their concentrations were found to vary depending on the location of capture. The increase in heavy metals content in bottom ashes was not found to lead to higher leachability and ecotoxicity compared to sewage sludges, suggesting that there could be opportunities for their further use. Mercury suffered vaporisation inside the reactor, thus leaving bottom ashes free of contamination by it. However, there was observed a strong retention of mercury in cyclone ashes due to the presence of unburned carbon which probably acted as an adsorbent. The effluent mercury was also found to be mostly associated with the particulate fraction, being less than 20% emitted in gaseous forms. The results suggested that the combustion of the sewage sludge could successfully be carried out and the amount of unburned carbon leaving the combustor but captured in cyclone was large enough to ensure substantial retention of mercury at low temperatures, hence could contribute to an improvement of the mercury release which still remains an issue of great concern to resolve during combustion of waste materials.

2004
Lapa, N., R. Barbosa, B. Mendes, and J. F. Santos Oliveira. "Chemical and ecotoxicological long-term behaviour of new materials for quarry back-filling and underground constructions." International RILEM Conference on the Use of Recycled Materials in Building and Structures. Eds. E. Vázquez, Ch. F. Hendriks, and G. M. T. Janssen. Barcelona: RILEM, 2004. 373-382. Abstractpaper_186_final_version.pdf

The main aim of the Valomat project was the development of new materials for quarry back-filling and underground constructions, based on the reuse of bottom ashes from MSWI. Bottom ashes were collected in six incineration plants of Europe. Some of them were selected for the development of new materials.
One task of this project comprised the study of the long-term behavior of new materials, under simulated conditions of environmental exposure. Three different scenarios were studied. For each scenario, a pilot plant was constructed and the new materials were studied under laboratory conditions or natural weather. The long-term behavior of these materials was assessed through the characterization of chemical and ecotoxicological properties of the leachates.
The chemical contamination and the ecotoxicological levels of the leachates were relatively low, although different levels had been determined for the three different scenarios. The immersion in dechlorinated tap water (scenario S1) had shown the highest emission levels of chlorides, sulphates, DOC, and Al, especially for the materials B2/1 and B2/2. The lowest ecotoxicological and chemical levels were determined in the scenario in which the materials were buried in a sieved soil.

Lapa, N., J. Morais, C. Borges, B. Mendes, and J. F. Santos Oliveira. "An integrated approach to assess the biodegradability of a wastewater containing chromium by using chemical and biological methods." Global Symposium on Recycling, Waste Treatment and Clean Technology, REWAS’2004. Eds. I. Gaballah, B. Mishra, R. Solozabal, and M. Tanaka. San Sebastián: TMS/INASMET, 2004. 1351-1362. Abstractrewas04_lapa_et_al.pdf

The Water Company of the North Alentejo (Águas do Norte Alentejano) (Portugal) has decided to implement a treatment plant to treat an urban wastewater with a significant influence of tannery effluents. The design of the wastewater treatment plant was attributed to a consortium coordinated by Sisaqua Company. Since the levels of the biodegradability and toxicity of the wastewater to be treated were unknown, Sisaqua Company asked the New University of Lisboa to develop and execute a monitoring plan to define the chemical composition and the levels of the biodegradability and toxicity of the wastewater.
A composite sampling procedure of the wastewater was performed during a daily working cycle of the tanneries. The composite sample was characterized for 19 chemical parameters. Five of these parameters were total Cr, Cr (VI), Zn, Cu and Al, which were determined in the dissolved and suspended fractions. The composite sample was also submitted to a biological test to assess its biodegradability degree. This assay was performed according to the methodology indicated in the test 301E of OECD [1], taking into account the amendment of 1992. A respirometric assay was carried out, to assess the toxic effect of the composite sample on the biological populations involved in the biological stabilization of organic compounds. This assay followed the “Sapromat” methodology developed by Brabander and Vandeputte [2]. Finally, the composite sample was submitted to a coagulation-flocculation process according to the methodologies proposed by Eckenfelder [3, 4] and Pereira [5]. The supernatants were characterized for the same chemical and biological parameters as it was described for the composite sample.
It was possible to conclude that the high levels of Cr present in the composite wastewater were mainly in the trivalent oxidation state. Since this oxidation state is less toxic for biological populations than the Cr (VI) and this metal was mainly in the suspended fraction, it was possible to obtain a biodegradability of the organic compounds quite similar to those observed for domestic wastewaters. The toxicity determined by the “Sapromat” method was slightly higher than those determined for domestic wastewaters. Nevertheless, this toxicity did not affect significantly the wastewater biodegradability. The Cr (III) was easily removed by a chemical coagulation-flocculation process.

2005
Lapa, N., R. Barbosa, S. Camacho, R. C. C. Monteiro, M. H. Fernandes, and J. F. Santos Oliveira. "Leaching behaviour of a glass produced from a MSWI bottom ash." Advanced Materials Forum III, III International Materials Symposium Materiais 2005. Ed. Paula Vilarinho. Universidade de Aveiro, Aveiro: Trans Tech Publications Inc., 2005. 1736-1741. Abstractlapa_et_al_-_to10.o3.pdf

This paper is mainly focused on the characterisation of a glass material (GM) obtained from the thermal treatment of a bottom ash (BA) produced at the Municipal Solid Waste (MSW) incineration plant of Valorsul. By melting the BA at 1400ºC during 2 hours, and without using any chemical additives, a homogeneous black-coloured glass was obtained. The thermal and mechanical properties of this glass were characterised. The thermal expansion coefficient, measured by dilatometry, was 9-10 x 10-6 per ºC and the modulus of rupture, determined by four-point bending test, was 75±6 MPa, which are similar values to those exhibited by commercial soda-lime-silica glasses used in structural applications. The chemical and the ecotoxicological leaching behaviour of the GM were also analysed. The GM was submitted to a leaching procedure composed of 15 sequential extraction cycles. A liquid/solid (L/S) ratio of 2 l/kg was applied in each cycle. The leachates were filtered through a membrane of PTFE (porosity: 0.45 µm). The filtered leachates were characterised for different chemical parameters and for an ecotoxicological indicator (bacterium Vibrio fischeri). The GM was also submitted to a microwave acidic digestion for the assessment of the total metal content. The crude BA was also submitted to the same experimental procedures. The GM showed levels of chemical emission and ecotoxicity for V. fischeri much lower than those determined for the crude BA. Similar characterisation studies will be pursued with the glass-ceramics produced by adequate thermal treatment of the glass, in order to investigate the effect of the crystallization on the final properties.

2006
Mahiout, A., R. Damann, J. Pera, A. Luonsi, M. Kolari, J. Siivinen, J. F. Santos Oliveira, N. Lapa, G. Pourcelly, and F. Aslan. "Industrial liquid effluents in the pulp and paper industry." Industrial Liquid Effluents - A Guide Book on the Treatment of Effluents from the Mining/Metallurgy, Paper, Plating and Textile Industries. Eds. M. Cox, P. Négré, and L. Yurramendi. Donostia - San Sebastián: INASMET-Tecnalia and European Commission, 2006. 33-73.
Lapa, N., R. Barbosa, S. Camacho, R. C. C. Monteiro, M. H. V. Fernandes, and J. S. Oliveira. "Leaching behaviour of a glass produced from a MSWI bottom ash." Materials Science Forum. 514-516 (2006): 1736-1741. AbstractWebsite

This paper is mainly focused on the characterisation of a glass material (GM) obtained from the thermal treatment of a bottom ash (BA) produced at the Municipal Solid Waste (MSW) incineration plant of Valorsul. By melting the BA at 1400ºC during 2 hours, and without using any chemical additives, a homogeneous black-coloured glass was obtained. The thermal and mechanical properties of this glass were characterised. The thermal expansion coefficient, measured by dilatometry, was 9-10 x 10-6 per ºC and the modulus of rupture, determined by four-point bending test, was 75±6 MPa, which are similar values to those exhibited by commercial soda-lime-silica glasses used in structural applications. The chemical and the ecotoxicological leaching behaviour of the GM were also analysed. The GM was submitted to a leaching procedure composed of 15 sequential extraction cycles. A liquid/solid (L/S) ratio of 2 l/kg was applied in each cycle. The leachates were filtered through a membrane of PTFE (porosity: 0.45 8m). The filtered leachates were characterised for different chemical parameters and for an ecotoxicological indicator (bacterium Vibrio fischeri). The GM was also submitted to a microwave acidic digestion for the assessment of the total metal content. The crude BA was also submitted to the same experimental procedures. The GM showed levels of chemical emission and ecotoxicity for V. fischeri much lower than those determined for the crude BA. Similar characterisation studies will be pursued with the glass-ceramics produced by adequate thermal treatment of the glass, in order to investigate the effect of the crystallization on the final properties.

2007
Lapa, N., R. Barbosa, M. H. Lopes, B. Mendes, P. Abelha, I. I. Gulyurtlu, and J. Santos Oliveira. "Chemical and ecotoxicological characterization of ashes obtained from sewage sludge combustion in a fluidised-bed reactor." Journal of Hazardous Materials. 147.1-2 (2007): 175-183. AbstractWebsite

In 1999, the DEECA/INETI and the UBiA/FCT/UNL started a researching project on the partition of heavy metals during the combustion of stabilised sewage sludge (Biogran®), in a fluidised-bed reactor, and on the quality of the bottom ashes and fly ashes produced. This project was entitled Bimetal and was funded by the Portuguese Foundation for Science and Technology. In this paper only the results on the combustion of Biogran® are reported. The combustion process was performed in two different trials, in which different amounts of sewage sludge and time of combustion were applied. Several ash samples were collected from the bed (bottom ashes) and from two cyclones (first cyclone and second cyclone ashes). Sewage sludge, bed material (sand) and ash samples were submitted to the leaching process defined in the European leaching standard EN 12457-2. The eluates were characterized for a set of inorganic chemical species. The ecotoxicological levels of the eluates were determined for two biological indicators (Vibrio fischeri and Daphnia magna). The results were compared with the limit values of the CEMWE French Regulation. The samples were also ranked according to an index based on the chemical characterization of the eluates. It was observed an increase of the concentration of metals along the combustion system. The ashes trapped in the second cyclone, for both combustion trials, showed the highest concentration of metals in the eluates. Chemically, the ashes of the second cyclone were the most different ones. In the ecotoxicological point of view, the ecotoxicity levels of the eluates of the ashes, for both combustion cycles, did not follow the same pattern as observed for the chemical characterization. The ashes of the first cyclone showed the highest ecotoxicity levels for V. fischeri and D. magna. This difference on chemical and ecotoxicological results proves the need for performing both chemical and ecotoxicological characterizations of the sub-products of such type of thermal processes.

2008
Dunea, Daniel, Adrian Dunea, Nuno Lapa, and Virgil Moise. "Developing a remote laboratory for environmental monitoring using mobile technology." Scientific Bulletin of Electrical Engineering Faculty. 2 (2008): 69-75. Abstractdunea_et_al_2008_developing_a_remote_laboratory_for_environ_monitoring_using_mobile_technology.pdfWebsite

This paper presents the mobile technology utilization in improving the remote access to the data acquisition processes of several automated monitoring system for air quality, water quality, and crop canopy microclimate. The system facilitates mobile environmental management and decision making by using in-situ measurements, GSM/GPRS informational fluxes, Pocket PCs, dGPS and mobile GIS resources. Data is retrieved via GSM/GPRS data modem to remote computer using digital (GSM) phone network. The main outcomes of this study were as follows: 1. designing the hardware, communication and software infrastructure of the system using telemetry features, 2. establishing the wireless connections and remote access from PDAs to the measurement servers, 3. programming and testing specific control virtual instruments (Vis) in NI LabVIEWTM, 4. obtaining a portable solution of statistical analysis and survey with PDA Vi (Virtual Instruments) interfaces for Pocket PC to gather, store, customize and report data combined with statistical processing functions, and 5. identifying mobile GIS applications for the environmental protection. The remote-accessing of the GIS server features, provided in-situ electronically reviews, mark up, and precise measurements of the site pollution plans. One possible solution to overcome the PDA hardware and software restraints is enabling the remote access and control of the DAQ and GIS software resources of the measurement server via internet.

2009
Bernardo, M., N. Lapa, R. Barbosa, M. Gonçalves, B. Mendes, F. Pinto, and I. Gulyurtlu. "Chemical and ecotoxicological characterization of solid residues produced during the co-pyrolysis of plastics and pine biomass." Journal of Hazardous Materials. 166.1 (2009): 309-317. AbstractWebsite

A mixture of 70% (w/w) pine biomass and 30% (w/w) plastics (mixture of polypropylene, polyethylene, and polystyrene) was subjected to pyrolysis at 400 °C, for 15 min, with an initial pressure of 40 MPa. Part of the solid residue produced was subjected to extraction with dichloromethane (DCM). The extracted residue (residue A) and raw residue (residue B) were analyzed by weight loss combustion and submitted to the leaching test ISO/TS 21268-2 using two different leachants: DCM (0.2%, v/v) and calcium chloride (0.001 mol/L). The concentrations of the heavy metals Cd, Cr, Ni, Zn, Pb and Cu were determined in the eluates and in the two residues. The eluates were further characterized by determining their pH and the concentrations of benzene, toluene, ethylbenzene and xylenes (BTEX). The presence of other organic contaminants in the eluates was qualitatively evaluated by gas chromatography, coupled with mass spectrometry. An ecotoxicological characterization was also performed by using the bio-indicator Vibrio fischeri. The chemical and ecotoxicological results were analyzed according to the French proposal of Criteria on the Evaluation Methods of Waste Ecotoxicity (CEMWE). Residue A was not considered to be ecotoxic by the ecotoxicological criterion (EC50 (30 min) ≥10%), but it was considered to be ecotoxic by the chemical criterion (Ni ≥ 0.5 mg/L). Residue B was considered to be ecotoxic by the ecotoxicological criterion: EC50 (30 min) ≤ 10%. Besides that, residue B was considered to be hazardous according the European legislation (BTEX concentrations higher than 100 ppb). The results indicate that volatile organic contaminants can be present in sufficient amounts in these residues and their eluates to induce ecotoxicity levels. The extraction of the pyrolysis residue with DCM was an efficient method for removing lighter organic contaminants.

Barbosa, R., N. Lapa, D. Boavida, H. Lopes, I. Gulyurtlu, and B. Mendes. "Co-combustion of coal and sewage sludge: chemical and ecotoxicological properties of ashes." Journal of Hazardous Materials. 170.2-3 (2009): 902-909. AbstractWebsite

The co-combustion of sewage sludge (SS) and coal is widely used for the treatment and thermal valorization of SS produced in wastewater treatment plants. The chemical and ecotoxicological properties of the ashes produced in this thermal treatment have not been fully studied. Two combustion tests were performed in a fluidized bed combustor. Colombian coal was used as fuel in test A. A blend (1 + 1) of this coal and a stabilized SS (Biogran®) was used in a second test B. Samples of the bottom and fly ashes trapped in two sequential cyclones were collected. The characterization of the ashes was focused on two main aspects: (1) the bulk content of a set of metals and (2) the characterization of eluates produced according to the European Standard leaching test EN 12457-2. The eluates were submitted to an ecotoxicological characterization for two bio-indicators. In what concerns the bulk content of ashes, both combustion tests have produced ashes with different compositions. The ashes formed during the co-combustion test have shown higher concentrations of metals, namely Cr, Cu, Ni, Pb, Zn and Fe for all ashes. The leaching test has shown low mobility of these elements from the by-products produced during the combustion and co-combustion tests. Cr and Cr(VI) were mainly detected in the eluates of the 1st cyclone ashes produced in both combustion tests and in the 2nd cyclone ashes produced in the co-combustion test.

Considering the ecotoxicity assays, the eluates of bottom and fly ashes for both combustion and co-combustion tests have shown low ecotoxic levels. The micro-crustacean Daphnia magna was generally more sensitive than the bacterium Vibrio fischeri. CEMWE criterion has allowed to classify the bottom ashes for both combustion and co-combustion tests as non-toxic residues and the fly ashes collected in both cyclones as toxic.

Bernardo, M., M. Gonçalves, N. Lapa, R. Barbosa, B. Mendes, F. Pinto, and I. Gulyurtlu. "Determination of aromatic compunds in leachates from pyrolysis solid residues using HS-GC-MS and DLLME-GC-MS." Talanta. 80.1 (2009): 104-108. AbstractWebsite

A method for the determination of 15 aromatic hydrocarbons in eluates from solid residues produced during the co-pyrolysis of plastics and pine biomass was developed. In a first step, several sampling techniques (headspace solid phase microextraction (HS-SPME), static headspace sampling (HS), and dispersive liquid–liquid microextraction (DLLME) were compared in order to evaluate their sensitivity towards these analytes. HS-SPME and HS sampling had the better performance, but DLLME was itself as a technique able to extract volatiles with a significant enrichment factor.

HS sampling coupled with GC–MS was chosen for method validation for the analytes tested. Calibration curves were constructed for each analyte with correlation coefficients higher than 0.999. The limits of detection were in the range of 0.66–37.85 ng/L. The precision of the HS method was evaluated and good repeatability was achieved with relative standard deviations of 4.8–13.2%. The recoveries of the analytes were evaluated by analysing fortified real eluate samples and were in the range of 60.6–113.9%.

The validated method was applied in real eluate samples. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the compounds in higher concentrations.

The DLLME technique coupled with GC–MS was used to investigate the presence of less volatile contaminants in eluate samples. This analysis revealed the presence of significant amounts of alkyl phenols and other aromatic compounds with appreciable water solubility.

Santos Oliveira, J. F., B. Mendes, and N. Lapa Resíduos: Gestão, Tratamento e sua Problemática em Portugal. Lisboa: Lidel, 2009.Website
Paradela, F., F. Pinto, I. Gulyurtlu, I. Cabrita, and N. Lapa. "Study of the co-pyrolysis of biomass and plastic wastes." Clean Technologies and Environmental Policy. 11.1 (2009): 115-122. AbstractWebsite

This work aimed to study the recovery of two types of waste by the process of pyrolysis. The obtained results show that the adding of a plastic mix improves the overall efficiency of the slow pyrolysis of pine. Therefore, it was possible to achieve higher liquid yields and less solid product than in the classic slow pyrolysis carbonization of biomass. The obtained liquids showed heating values similar to that of heating fuel oil. The gas products had energetic contents superior to that of producer gas, and the obtained solid fractions showed heating values higher than some coals. There were also identified some typical products of fast biomass pyrolysis used as raw material in several industries. The effects of experimental conditions in product yield and composition were also studied. The parameters that showed higher influence were (with its increase): reaction time on gas product composition (increase of the alkane content) and on liquid composition (increase in aromatics content); reaction temperature on product yield (decrease of liquid yield with increase of solids and gases) and on gas product composition (increase in alkane content); initial pressure on liquid composition (increase in the aromatics content) and mainly the pine content of the initial mixture on products yield (increase of gas and solid yield with a decrease in liquids) and on the gas product composition (favouring CO and CO2 formation).