Mechanical testing

Flexural strengthening of columns with CFRP composites and stainless steel: Cyclic behavior, Faustino, Pedro, and Chastre Carlos , Journal of Structural Engineering, 21 September 201, Volume 142, Number 2, p.04015136, (2016) AbstractWebsite

This study presents the testing, completion, and analysis of different external strengthening systems applied to rectangular reinforced concrete columns with rounded corners. The experimental study included confinement strengthening with carbon-fiberreinforcedpolymer (CFRP) sheets, longitudinal strengthening with CFRP laminates and confining CFRP jacket, longitudinal strengtheningwith stainless steel bars and confining CFRP jacket, tested column until reinforcing steel failure, repair and CFRP confining jacket,and longitudinal strengthening with stainless steel bars. The analysis of the experimental results included lateral load-displacement relationship, energy dissipation, ductility, and curvature damage assessment classifications. It was concluded that the use of externallongitudinal strengthening combined with CFRP confinement is effective for enhancing performance and is viable in terms of execution. The load capacity increase due to strengthening reached 36–46% with good ductile behavior (failure was reached at 4.4% drift ratio). Despite some differences between CFRP laminates and stainless steel, all columns presented moderate degrees of damage between 1 and 2% drift ratio and minor damage degree until 1% drift ratio.

Flexural Strengthening of Old Timber Floors with Laminated Carbon Fiber Reinforced Polymers, Biscaia, Hugo, Chastre Carlos, Cruz David, and Franco Noel , Journal of Composites for Construction, p.04016073, (2016) AbstractWebsite

A set of three old suspended timber floors were flexurally-strengthened with Carbon Fiber Reinforced Polymers (CFRP) strips in order to investigate the effectiveness of externally bonding FRP to their soffits. The specimens were from an old building and 740 mm-wide bands were transferred to the laboratory in order to be tested in a 4-point bending test. One specimen was tested with no strengthening system and the results obtained were used as reference values for comparison with the specimens those were externally bonded and reinforced (EBR) with CFRP strips. Two similar EBR systems were studied: (i) keeping both ends of the CFRP strips free of any restriction (traditional technique); and (ii) embedding both ends of the CFRP strips into the timber, thus providing a bonding anchorage of the strips (new technique). The installation of the new strengthening system comprises the opening of holes in the timber and the creation of a transition curve between the holes and the timber surface. This transition curve allows a smooth transition of the CFRP laminate between the hole and the timber surface, thus avoiding stress concentrations in this area. After the opening of the holes, the resin is applied inside the hole and on the beam surface, and then the CFRP laminate is mounted. The load-carrying capacity of the specimens, the rupture modes, the strains and bond stress distributions within the CFRP-to-timber interface are presented. A nonlinear numerical simulation of the specimens based on the mid-span cross-sectional equilibrium is also presented. The results showed that the use of the new strengthening system enhances the performance of the specimens when compared with the traditional strengthening system.

Experimental evaluation of bonding between CFRP laminates and different structural materials, Biscaia, Hugo, Chastre Carlos, Borba Isabel, Silva Cinderela, and Cruz David , Journal of Composites for Construction, Volume 20, Number 3, p.04015070, (2016) AbstractWebsite

This study presents an analysis of Carbon Fiber Reinforced Polymers (CFRP)-to-parent material interfaces based on 40 single-lap shear tests intended to highlight the strength of the interfaces under fracture mode II. Three different substrates are analyzed: timber;concrete and steel, using the same CFRP laminates and adhesive agent. The Externally Bonded Reinforcement (EBR) technique was used throughout the study. The results show that the CFRP-to-timber interfaces had the highest strength but also showed that these interfaces need a longer bonded length in order to reach maximum strength, i.e., CFRP-to-timber interfaces had the longest effective bond length. The local non-linear bond-slip curve of CFRP-to-concrete can be approximated to exponential curves, whereas the CFRP-to-timber or steel interfaces showed tri-linear and bi-linear bond-slip relations, respectively. Also, the CFRP-to-timber interfaces revealed the highest fracture energy.

Bond-slip model for FRP-to-concrete bonded joints under external compression, Biscaia, Hugo C., Chastre Carlos, and Silva Manuel A. G. , Composites Part B: Engineering, 10//, Volume 80, p.246-259, (2015) AbstractWebsite

The influence of compressive stresses exerted on FRP-concrete joints created by external strengthening of structural members on the performance of the system requires better understanding especially when mechanical devices are used to anchor the externally bonded reinforcement (EBR). The numerical modelling of those systems is a tool that permits insight into the performance of the corresponding interfaces and was used in the present study, essentially directed to analyse the effectiveness of EBR systems under compressive stresses normal to the composite surface applied to GFRP-to-concrete interfaces. The compressive stresses imposed on the GFRP-to-concrete interface model the effect produced by a mechanical anchorage system applied to the EBR system. An experimental program is described on which double-lap shear tests were performed that created normal stresses externally applied on the GFRP plates. A corresponding bond-slip model is proposed and the results of its introduction in the numerical analysis based in an available 3D finite element code are displayed, showing satisfactory agreement with the experimental data. The results also showed that lateral compressive stresses tend to increase the maximum bond stress of the interface and also originate a residual bond stress which has significant influence on the interface strength. Also, the strength of the interface increases with the increase of the bonded length which have consequences on the definition of the effective bond length.

Non-linear analytical model of composites based on basalt textile reinforced mortar under uniaxial tension, Larrinaga, Pello, Chastre Carlos, San-José José T., and Garmendia Leire , Composites Part B: Engineering, 12//, Volume 55, p.518-527, (2013) AbstractWebsite

The recent development of inorganic based composites as low-cost materials in reinforced concrete structural strengthening and precast thin-walled components, requires the creation of models that predict the mechanical behaviour of these materials. Textile Reinforced Mortar (TRM) shows complex stress–strain behaviour in tension derived from the heterogeneity of its constituent materials. This complexity is mainly caused by the formation of several cracks in the inorganic matrix. The multiple cracking leads to a decrease in structural stiffness. Due to the severe conditions of the serviceability limit state in structural elements, the prediction of the stress–strain curve is essential for design and calculation purposes. After checking other models, an empirical nonlinear approach, which is based on the crack control expression included in the Eurocode 2, is proposed in this paper. Following this scope, this paper presents an experimental campaign focused on 31 TRM specimens reinforced with four different reinforcing ratios. The results are analysed and satisfactorily contrasted with the presented non-linear approach.