Publications

Export 7 results:
Sort by: Author Title Type [ Year  (Desc)]
2017
Barros AA, Oliveira C, Ribeiro AJ, Autorino R, Reis RL, Duarte AR, Lima E. {In vivo assessment of a novel biodegradable ureteral stent}. World Journal of Urology. 2017. Abstract

© 2017 Springer-Verlag GmbH Germany, part of Springer Nature Purpose: To perform an in vivo assessment of a newly developed biodegradable ureteral stent (BUS) produced with natural-based polymers. Methods: The BUS is based on a patented technology combining the injection process with the use of supercritical fluid technology. Study was conducted at ICVS—University of Minho (Braga, Portugal) and a total of ten domestic pigs were used. In seven animals, the experimental BUS stent was inserted, whereas in the remaining a commercially available stent was used (6-Fr Biosoft ® duo stents, Porges Coloplast, Denmark). Post-stenting intravenous pyelogram was used to evaluate the degree of hydronephrosis. The in vivo stent degradation was measured as function of the weight loss. Moreover, the tensile properties of the BUS were tested during in vivo degradation. After maximum 10 days, animals were killed and necropsy was performed. Tissues were compared between the stented groups as well as between the non-stented contralateral ureters and stented ureters in each group. Biocompatibility was assessed by histopathological grading. Results: In all cases, the BUS was only visible during the first 24 h on X-ray, and in all cases the BUS was completely degraded in urine after 10 days, as confirmed on necropsy. During the degradation process, the mechanical properties of the BUS decreased, while the commercial ureteral stents remained constant. At all time-points after stent insertion, the level of hydronephrosis was minimal. Overall, animals stented with BUS had an average grade of hydronephrosis which was lower compared to the controls. The BUS showed better pathological conditions, and hence better biocompatibility when compared with commercial stents. Conclusions: Notwithstanding the limitations of the present study, the in vivo testing of our novel natural origin polymer-based BUS suggests this device to feature homogeneous degradation, good urine drainage, and high biocompatibility. Next steps will be to increase its stability, and to improve the radiopacity without compromising its degradation. Ultimately, clinical studies will be required to determine the safety and feasibility of its use in humans.

Barros AA, Oliveira C, Reis RL, Lima E, Duarte AR. {In Vitro and Ex Vivo Permeability Studies of Paclitaxel and Doxorubicin From Drug-Eluting Biodegradable Ureteral Stents}. Journal of Pharmaceutical Sciences. 2017;106. Abstract

© 2017 American Pharmacists Association® A drug-eluting biodegradable ureteral stent (BUS) has been developed as a new approach for the treatment of urothelial tumors of upper urinary tract cancer. In a previous work, this system has proven to be a good carrier for anticancer drugs as a potential effective and sustainable intravesical drug delivery system. BUS has revealed to reduce in 75{%} the viability of human urothelial cancer cells (T24) after 72 h of contact and demonstrated minimal cytotoxic effect on human umbilical vein endothelial cells (HUVECs) which were used as a control. In this work, we studied the permeability of the anticancer drugs, such as paclitaxel and doxorubicin, alone or released from the BUS developed. We used 3 different membranes to study the permeability: polyethersulfone (PES) membrane, HUVECs cell monolayer, and an ex vivo porcine ureter. The ureter thickness was measured (864.51 $μ$m) and histological analysis was performed to confirm the integrity of urothelium. Permeability profiles were measured during 8 h for paclitaxel and doxorubicin. The drugs per se have shown to have a different profile and as expected, increasing the complexity of the membrane to be permeated, the permeability decreased, with the PES being more permeable and the ex vivo ureter tissue being less permeable. The molecular weight has also shown to influence the permeability of each drug and a higher percentage for doxorubicin (26{%}) and lower for paclitaxel (18{%}) was observed across the ex vivo ureter. The permeability (P), diffusion (D), and partition (K d ) coefficients of paclitaxel and doxorubicin through the permeable membranes were calculated. Finally, we showed that paclitaxel and doxorubicin drugs released from the BUS were able to remain in the ex vivo ureter and only a small amount of the drugs can across the different permeable membranes with a permeability of 3{%} for paclitaxel and 11{%} for doxorubicin. The estimated amount of paclitaxel that remains in the ex vivo ureter tissue is shown to be effective to affect the cancer cell and not affect the noncancer cells.

2016
Barros AA, Browne S, Oliveira C, Lima E, Duarte AR, Healy KE, Reis RL. {Drug-eluting biodegradable ureteral stent: New approach for urothelial tumors of upper urinary tract cancer}. International Journal of Pharmaceutics. 2016;513. Abstract

© 2016 Elsevier B.V. Upper urinary tract urothelial carcinoma (UTUC) accounts for 5–10{%} of urothelial carcinomas and is a disease that has not been widely studied as carcinoma of the bladder. To avoid the problems of conventional therapies, such as the need for frequent drug instillation due to poor drug retention, we developed a biodegradable ureteral stent (BUS) impregnated by supercritical fluid CO 2 (scCO 2 ) with the most commonly used anti-cancer drugs, namely paclitaxel, epirubicin, doxorubicin, and gemcitabine. The release kinetics of anti-cancer therapeutics from drug-eluting stents was measured in artificial urine solution (AUS). The in vitro release showed a faster release in the first 72 h for the four anti-cancer drugs, after this time a plateau was achieved and finally the stent degraded after 9 days. Regarding the amount of impregnated drugs by scCO 2 , gemcitabine showed the highest amount of loading (19.57 $μ$g drug /mg polymer: 2{%} loaded), while the lowest amount was obtained for paclitaxel (0.067 $μ$g drug /mg polymer : 0.01{%} loaded). A cancer cell line (T24) was exposed to graded concentrations (0.01–2000 ng/ml) of each drugs for 4 and 72 h to determine the sensitivities of the cells to each drug (IC 50 ). The direct and indirect contact study of the anti-cancer biodegradable ureteral stents with the T24 and HUVEC cell lines confirmed the anti-tumoral effect of the BUS impregnated with the four anti-cancer drugs tested, reducing around 75{%} of the viability of the T24 cell line after 72 h and demonstrating minimal cytotoxic effect on HUVECs.

2015
Barros AA, Oliveira C, Reis RL, Lima E, Duarte AR. {Ketoprofen-eluting biodegradable ureteral stents by CO{\textless}inf{\textgreater}2{\textless}/inf{\textgreater}impregnation: In vitro study}. International Journal of Pharmaceutics. 2015;495. Abstract

© 2015 Elsevier B.V. Ureteral stents are indispensable tools in urologic practice. The main complications associated with ureteral stents are dislocation, infection, pain and encrustation. Biodegradable ureteral stents are one of the most attractive designs with the potential to eliminate several complications associated with the stenting procedure. In this work we hypothesize the impregnation of ketoprofen, by CO 2 -impregnation in a patented biodegradable ureteral stent previously developed in our group. The biodegradable ureteral stents with each formulation: alginate-based, gellan gum-based were impregnated with ketoprofen and the impregnation conditions tested were 100 bar, 2 h and three different temperatures (35 °C, 40°C and 50°C). The impregnation was confirmed by FTIR and DSC demonstrated the amorphization of the drug upon impregnation. The in vitro elution profile in artificial urine solution (AUS) during degradation of a biodegradable ureteral stent loaded with ketoprofen was evaluated. According to the kinetics results these systems have shown to be very promising for the release ketoprofen in the first 72 h, which is the necessary time for anti-inflammatory delivery after the surgical procedure. The in vitro release studied revealed an influence of the temperature on the impregnation yield, with a higher impregnation yield at 40°C. Higher yields were also obtained for gellan gum-based stents. The non-cytotoxicity characteristic of the developed ketoprofen-eluting biodegradable ureteral stents was evaluated in L929 cell line by MTS assay which demonstrated the feasibility of this product as a medical device.

2013
Silva SS, Duarte AR, Oliveira JM, Mano JF, Reis RL. {Alternative methodology for chitin-hydroxyapatite composites using ionic liquids and supercritical fluid technology}. Journal of Bioactive and Compatible Polymers. 2013;28. Abstract

An alternative, green method was used to develop chitin-based biocomposite (ChHA) materials by an integrated strategy using ionic liquids, supercritical fluid drying, and salt leaching. ChHA matrices were produced by dissolving chitin in 1-butyl-methylimidazolium acetate along with salt and/or hydroxyapatite particles and then subsequent drying. The ChHA composite formed had a heterogeneous porous microstructure with 65{%}-85{%} porosity and pore sizes in the range of 100-300 $μ$m. The hydroxyapatite was found to be well distributed within the composite structures and had a positive effect in the viability and proliferation of osteoblast-like cells, in vitro. Our findings indicate that these ChHA matrices have potential applications in bone tissue engineering. © The Author(s) 2013.

2012
Correia C, Pereira AL, Duarte AR, Frias AM, Pedro AJ, Oliveira JT, Sousa RA, Reis RL. {Dynamic culturing of cartilage tissue: The significance of hydrostatic pressure}. Tissue Engineering - Part A. 2012;18. Abstract

Human articular cartilage functions under a wide range of mechanical loads in synovial joints, where hydrostatic pressure (HP) is the prevalent actuating force. We hypothesized that the formation of engineered cartilage can be augmented by applying such physiologic stimuli to chondrogenic cells or stem cells, cultured in hydrogels, using custom-designed HP bioreactors. To test this hypothesis, we investigated the effects of distinct HP regimens on cartilage formation in vitro by either human nasal chondrocytes (HNCs) or human adipose stem cells (hASCs) encapsulated in gellan gum (GG) hydrogels. To this end, we varied the frequency of low HP, by applying pulsatile hydrostatic pressure or a steady hydrostatic pressure load to HNC-GG constructs over a period of 3 weeks, and evaluated their effects on cartilage tissue-engineering outcomes. HNCs (10×10 6 cells/mL) were encapsulated in GG hydrogels (1.5{%}) and cultured in a chondrogenic medium under three regimens for 3 weeks: (1) 0.4 MPa Pulsatile HP; (2) 0.4 MPa Steady HP; and (3) Static. Subsequently, we applied the pulsatile regimen to hASC-GG constructs and varied the amplitude of loading, by generating both low (0.4 MPa) and physiologic (5 MPa) HP levels. hASCs (10×10 6 cells/mL) were encapsulated in GG hydrogels (1.5{%}) and cultured in a chondrogenic medium under three regimens for 4 weeks: (1) 0.4 MPa Pulsatile HP; (2) 5 MPa Pulsatile HP; and (3) Static. In the HNC study, the best tissue development was achieved by the pulsatile HP regimen, whereas in the hASC study, greater chondrogenic differentiation and matrix deposition were obtained for physiologic loading, as evidenced by gene expression of aggrecan, collagen type II, and sox-9; metachromatic staining of cartilage extracellular matrix; and immunolocalization of collagens. We thus propose that both HNCs and hASCs detect and respond to physical forces, thus resembling joint loading, by enhancing cartilage tissue development in a frequency- and amplitude-dependant manner. © Copyright 2012, Mary Ann Liebert, Inc.

2010
Sabil KM, Duarte AR, Zevenbergen J, Ahmad MM, Yusup S, Omar AA, Peters CJ. {Kinetic of formation for single carbon dioxide and mixed carbon dioxide and tetrahydrofuran hydrates in water and sodium chloride aqueous solution}. International Journal of Greenhouse Gas Control. 2010;4:798-805. Abstractpdf

A laboratory-scale reactor system is built and operated to measure the kinetic of formation for single and mixed carbon dioxide-tetrahydrofuran hydrates. The T-cycle method, which is used to collect the kinetic data, is briefly discussed. For single carbon dioxide hydrate, the induction time decreases with the increase of the initial carbon dioxide pressure up to 2.96. MPa. Beyond this pressure, the induction time is becoming relatively constant with the increase of initial carbon dioxide pressure indicating that the liquid phase is completely supersaturated with carbon dioxide. Experimental results show that the inclusion of tetrahydrofuran reduces the induction time required for hydrate formation. These observations indicate hydrate nucleation process and onset growth are more readily to occur in the presence of tetrahydrofuran. In contrast, the presence of sodium chloride prolongs the induction time due to clustering of water molecules with the ions and the salting-out effects. It is also shown that the degree of subcooling required for hydrate formation is affected by the presence of tetrahydrofuran and sodium chloride in the hydrate forming system. The presence of tetrahydrofuran in the hydrate system significantly reduces the amount of carbon dioxide uptake. The apparent rate constant, k, for those systems are reported. © 2010.