Recent Publications

Export 91 results:
Sort by: Author Title Type [ Year  (Desc)]
2014
Amaro, P., C. I. Szabo, S. Schlesser, A. Gumberidze, E. G. Kessler, A. Henins, E. O. Le Bigot, M. Trassinelli, J. M. Isac, P. Travers, M. Guerra, J. P. Santos, and P. Indelicato. "A vacuum double-crystal spectrometer for reference-free X-ray spectroscopy of highly charged ions." Radiation Physics and Chemistry 98 (2014): 132-149. AbstractWebsite

Radiation Physics and Chemistry, 98 + (2014) 132-149. doi:10.1016/j.radphyschem.2014.01.015

Santos, S. C. P. L., M. E. Cruz, A. M. E. Barroso, C. P. S. Fonseca, M. Guerra, M. L. Carvalho, and J. P. Santos. "Elemental characterization of plants and soils in Panasqueira tungsten mining region." Journal of Soils Sediments 14 (2014): 778. AbstractWebsite

... Title Elemental characterization of plants and soils in Panasqueira tungsten mining region Journal Journal of Soils and Sediments Volume 14, Issue 4 , pp 778-784 Cover Date 2014-04-01 DOI 10.1007 / s11368 - 013 - 0788 - x Print ISSN 1439-0108 Online ISSN 1614-7480 ...

Santos, S. C. P. L., M. E. Cruz, A. M. E. Barroso, C. P. S. Fonseca, M. Guerra, M. L. Carvalho, and J. P. Santos. "Elemental characterization of plants and soils in Panasqueira tungsten mining region." Journal of Soils Sediments 14 (2014): 778. AbstractWebsite

... Title Elemental characterization of plants and soils in Panasqueira tungsten mining region Journal Journal of Soils and Sediments Volume 14, Issue 4 , pp 778-784 Cover Date 2014-04-01 DOI 10.1007 / s11368 - 013 - 0788 - x Print ISSN 1439-0108 Online ISSN 1614-7480 ...

2013
Amaro, P., S. Schlesser, M. Guerra, E. Le Bigot, J. P. Santos, C. I. Szabo, A. Gumberidze, and P. Indelicato. "Absolute measurements and simulations of x-ray line energies of highly charged ions with a double-crystal spectrometer." T156 (2013): 014104. AbstractWebsite
n/a
Amaro, P., S. Schlesser, M. Guerra, E. Le Bigot, J. P. Santos, C. I. Szabo, A. Gumberidze, and P. Indelicato. "Absolute measurements and simulations of x-ray line energies of highly charged ions with a double-crystal spectrometer." Physica Scripta T156 (2013): 014104. AbstractWebsite
n/a
Szabo, C. I., P. Amaro, M. Guerra, J. P. Santos, A. Gumberidze, J. Attard, and P. Indelicato. "Ion temperature and x-ray line width measurements of highly charged argon ions in an ECR ion source." Physica Scripta T156 (2013): 014077. AbstractWebsite
n/a
Szabo, C. I., P. Amaro, M. Guerra, J. P. Santos, A. Gumberidze, J. Attard, and P. Indelicato. "Ion temperature and x-ray line width measurements of highly charged argon ions in an ECR ion source." Physica Scripta T156 (2013): 014077. AbstractWebsite
n/a
Pé-Leve Santos, Sara C., Mariana Eloy Cruz, António M. E. Barroso, Catarina P. S. Fonseca, Mauro Guerra, Maria Luisa Carvalho, and Jose Paulo Santos. "Elemental characterization of plants and soils in Panasqueira tungsten mining region." Online (2013). AbstractWebsite
n/a
Guerra, M., R. M. Pinto, J. P. Santos, and A. C. S. Paiva. "Towards the assignment of the REMPI spectrum of Ph 2O using CIS and TD-DFT methods." Molecular Physics 111 (2013): 3311-3319. AbstractWebsite
n/a
Guerra, M., P. Amaro, C. I. Szabo, A. Gumberidze, P. Indelicato, and J. P. Santos. "Analysis of the charge state distribution in an ECRIS Ar plasma using high-resolution x-ray spectra." Journal of Physics B: Atomic, Molecular and Optical Physics 46 (2013): 065701. AbstractWebsite

In this work, we obtained a charge state distribution inside an Ar plasma produced by an electron–cyclotron-resonance ion source. The processes that lead to the observed lines in x-ray spectra are identified and included in the simulated x-ray spectrum. The geometrical constraints of the flat double crystal spectrometer, used to measure the x-ray spectrum, are investigated as they are crucial for correctly obtaining the ion densities from the observed transition amplitudes. Multiple electron impact ionization is included, and a realistic electron velocity distribution is taken into account. The charge state distribution of the Ar ions is compared to measured extracted ionic currents.

Guerra, M., F. Parente, and J. P. Santos. "Electron impact ionization cross sections of several ionization stages of Kr, Ar and Fe." International Journal of Mass Spectrometry 348 (2013): 1-8. AbstractWebsite

International Journal of Mass Spectrometry, 348 (2013) 1-8. doi:10.1016/j.ijms.2013.02.011

Guerra, M., F. Parente, and J. P. Santos. "Electron impact ionization cross sections of several ionization stages of Kr, Ar and Fe." International Journal of Mass Spectrometry 348 (2013): 1-8. AbstractWebsite

International Journal of Mass Spectrometry, 348 (2013) 1-8. doi:10.1016/j.ijms.2013.02.011

Guerra, M., R. M. Pinto, J. P. Santos, and A. C. S. Paiva. "Towards the assignment of the REMPI spectrum of Ph 2O using CIS and TD-DFT methods." Molecular Physics 111 (2013): 3311-3319. AbstractWebsite
n/a
Guerra, M., P. Amaro, C. I. Szabo, A. Gumberidze, P. Indelicato, and J. P. Santos. "Analysis of the charge state distribution in an ECRIS Ar plasma using high-resolution x-ray spectra." Journal of Physics B: Atomic, Molecular and Optical Physics 46 (2013): 065701. AbstractWebsite

In this work, we obtained a charge state distribution inside an Ar plasma produced by an electron–cyclotron-resonance ion source. The processes that lead to the observed lines in x-ray spectra are identified and included in the simulated x-ray spectrum. The geometrical constraints of the flat double crystal spectrometer, used to measure the x-ray spectrum, are investigated as they are crucial for correctly obtaining the ion densities from the observed transition amplitudes. Multiple electron impact ionization is included, and a realistic electron velocity distribution is taken into account. The charge state distribution of the Ar ions is compared to measured extracted ionic currents.

Szabo, Csilla I., Pedro Amaro, Mauro Guerra, Sophie Schlesser, Alexander Gumberidze, Jose Paulo Santos, and Paul Indelicato. "Reference free, high-precision measurements of transition energies in few electron argon ions." AIP APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY: Twenty-Second International Conference 1525 (2013): 68-72. AbstractWebsite

The use of a vacuum double crystal spectrometer, coupled to an electron-cyclotron resonance ion source (ECRIS), allows to measure low-energy x-ray transitions energies in highly-charged ions with accuracies of the order of a few parts per million. We have used this installation to measure the 1s2p 1 P1 - 1s2 1 S0 diagram line and the 1s2s 3 S1 - 1s2 1 S0 forbidden M1 transition energies in helium-like argon, the 1s2s2p 2 P j 1s2 2s 2 S1/2 transitions in lithium-like argon and the 1s2s2 2p 1 P1 - 1s2 2s2 1 S0 transition in beryllium-like argon. These transition measurements have accuracies between 2 and 4 ppm depending on the line intensity. Thanks to the excellent agreement between the simulations and the measurements, we were also able to measure the transition width of all the allowed transitions. The results are compared to recent QED and relativistic many-body calculations.

Szabo, Csilla I., Pedro Amaro, Mauro Guerra, Sophie Schlesser, Alexander Gumberidze, Jose Paulo Santos, and Paul Indelicato. "Reference free, high-precision measurements of transition energies in few electron argon ions." AIP Conf. Proc. 1525 (2013): 68-72. AbstractWebsite

The use of a vacuum double crystal spectrometer, coupled to an electron-cyclotron resonance ion source (ECRIS), allows to measure low-energy x-ray transitions energies in highly-charged ions with accuracies of the order of a few parts per million. We have used this installation to measure the 1s2p 1 P1 - 1s2 1 S0 diagram line and the 1s2s 3 S1 - 1s2 1 S0 forbidden M1 transition energies in helium-like argon, the 1s2s2p 2 P j 1s2 2s 2 S1/2 transitions in lithium-like argon and the 1s2s2 2p 1 P1 - 1s2 2s2 1 S0 transition in beryllium-like argon. These transition measurements have accuracies between 2 and 4 ppm depending on the line intensity. Thanks to the excellent agreement between the simulations and the measurements, we were also able to measure the transition width of all the allowed transitions. The results are compared to recent QED and relativistic many-body calculations.

2012
Guimarães, Diana, Maria Luisa Carvalho, Vera Geraldes, Isabel Rocha, Luís Cerqueira Alves, and Jose Paulo Santos. "Lead in liver and kidney of exposed rats: Aging accumulation study." J. Trace Elem. Med Biol. 26 (2012): 285. AbstractWebsite

The concentration of lead in liver and kidneys of Wistar rats, fed with lead since fetal period in relation to their age and to a control group, was determined. A group of rats was exposed to lead acetate (n=30) in drinking water and the other group was exposed to normal water (n=20). Samples were collected from rats aging between 1 and 11 months and were analyzed by Energy Dispersive X-ray Fluorescence (EDXRF) without any chemical preparation. The EDXRF results were assessed by the PIXE (Proton Induced X-ray Emission) technique. The formaldehyde used to preserve the samples was also analyzed by ETAAS (Electro-Thermal Atomic Absorption Spectrometry) in order to verify if there was any loss of lead from the samples to the formaldehyde. We found that the loss was not significant (<2%). Concerning the mean values of the lead concentration measured in the contaminated soft tissues, in liver they range from 6 to 22μgg(-1), and in kidneys from 44 to 79μgg(-1). The control rats show, in general, values below the EDXRF detection limit (2μgg(-1)). The ratio kidney/liver ranges from 2 to 10 and is strongly positively correlated with the age of the animals. A Spearman correlation matrix to investigate the correlation between elemental concentrations and the dependence of these concentrations with age showed that there is a strong positive correlation with age for lead in the liver but not in the kidney. The correlation matrix showed also that the concentration of lead in these two soft tissues is not correlated. The lead accumulation in liver is made by different plateaus that strongly decrease with age. It was verified the existence of two levels of accumulation in kidney, not very highlighted, which might be indicative of a maximum accumulation level for lead in kidney.

Guimarães, Diana, Maria Luisa Carvalho, Vera Geraldes, Isabel Rocha, Luís Cerqueira Alves, and Jose Paulo Santos. "Lead in liver and kidney of exposed rats: Aging accumulation study." Journal of Trace Elements in Medicine and Biology 26 (2012): 285. AbstractWebsite

The concentration of lead in liver and kidneys of Wistar rats, fed with lead since fetal period in relation to their age and to a control group, was determined. A group of rats was exposed to lead acetate (n=30) in drinking water and the other group was exposed to normal water (n=20). Samples were collected from rats aging between 1 and 11 months and were analyzed by Energy Dispersive X-ray Fluorescence (EDXRF) without any chemical preparation. The EDXRF results were assessed by the PIXE (Proton Induced X-ray Emission) technique. The formaldehyde used to preserve the samples was also analyzed by ETAAS (Electro-Thermal Atomic Absorption Spectrometry) in order to verify if there was any loss of lead from the samples to the formaldehyde. We found that the loss was not significant (<2%). Concerning the mean values of the lead concentration measured in the contaminated soft tissues, in liver they range from 6 to 22μgg(-1), and in kidneys from 44 to 79μgg(-1). The control rats show, in general, values below the EDXRF detection limit (2μgg(-1)). The ratio kidney/liver ranges from 2 to 10 and is strongly positively correlated with the age of the animals. A Spearman correlation matrix to investigate the correlation between elemental concentrations and the dependence of these concentrations with age showed that there is a strong positive correlation with age for lead in the liver but not in the kidney. The correlation matrix showed also that the concentration of lead in these two soft tissues is not correlated. The lead accumulation in liver is made by different plateaus that strongly decrease with age. It was verified the existence of two levels of accumulation in kidney, not very highlighted, which might be indicative of a maximum accumulation level for lead in kidney.

Santos, J. P., M. Guerra, and F. Parente. "New expression for the K-shell ionization." J. Phys.: Conf. Ser. 388 (2012): 042047. AbstractWebsite

A new expression for the total K-shell ionization cross section by electron impact based on the rela- tivistic extension of the binary encounter Bethe (RBEB) model, valid from ionization threshold up to relativistic energies, is proposed. The new MRBEB expression is used to calculate the K-shell ionization cross sections by electron impact for the selenium atom. Comparison with all, to our knowledge, available experimental data shows good agreement.

Santos, J. P., M. Guerra, and F. Parente. "New expression for the K-shell ionization." Journal of Physics: Conference Series 388 (2012): 042047. AbstractWebsite

A new expression for the total K-shell ionization cross section by electron impact based on the rela- tivistic extension of the binary encounter Bethe (RBEB) model, valid from ionization threshold up to relativistic energies, is proposed. The new MRBEB expression is used to calculate the K-shell ionization cross sections by electron impact for the selenium atom. Comparison with all, to our knowledge, available experimental data shows good agreement.

Guerra, M., F. Parente, P. Indelicato, and J. P. Santos. "Modified binary encounter Bethe model for electron-impact ionization." International Journal of Mass Spectrometry 313 (2012): 1. AbstractWebsite

Theoretical expressions for ionization cross sections by electron impact based on the binary encounter Bethe (BEB) model, valid from ionization threshold up to relativistic energies, are proposed.The new modified BEB (MBEB) and its relativistic counterpart (MRBEB) expressions are simpler than the BEB (nonrelativistic and relativistic) expressions because they require only one atomic parameter, namely the binding energy of the electrons to be ionized, and use only one scaling term for the ionization of all sub-shells.The new models are used to calculate the K-, L- and M-shell ionization cross sections by electron impact for several atoms with Z from 6 to 83. Comparisons with all, to the best of our knowledge, available experimental data show that this model is as good or better than other models, with less complexity.

Amaro, Pedro, Sophie Schlesser, Mauro Guerra, Eric-Olivier Le Bigot, Jean-Michel Isac, Pascal Travers, Jose Paulo Santos, Csilla Szabo, Alexandre Gumberidze, and Paul Indelicato. "Absolute Measurement of the Relativistic Magnetic Dipole Transition Energy in Heliumlike Argon." Phys. Rev. Lett. 109 (2012): 043005. AbstractWebsite

The 1s2s 3S1 ! 1s2 1S0 relativistic magnetic dipole transition in heliumlike argon, emitted by the plasma of an electron-cyclotron resonance ion source, has been measured using a double-flat crystal x-ray spectrometer. Such a spectrometer, used for the first time on a highly charged ion transition, provides absolute (reference-free) measurements in the x-ray domain. We find a transition energy of 3104.1605(77) eV (2.5 ppm accuracy). This value is the most accurate, reference-free measurement done for such a transition and is in good agreement with recent QED predictions.

Amaro, Pedro, Sophie Schlesser, Mauro Guerra, Eric-Olivier Le Bigot, Jean-Michel Isac, Pascal Travers, Jose Paulo Santos, Csilla Szabo, Alexandre Gumberidze, and Paul Indelicato. "Absolute Measurement of the Relativistic Magnetic Dipole Transition Energy in Heliumlike Argon." Physical Review Letters 109 (2012): 043005. AbstractWebsite

The 1s2s 3S1 - 1s2 1S0 relativistic magnetic dipole transition in heliumlike argon, emitted by the plasma of an electron-cyclotron resonance ion source, has been measured using a double-flat crystal x-ray spectrometer. Such a spectrometer, used for the first time on a highly charged ion transition, provides absolute (reference-free) measurements in the x-ray domain. We find a transition energy of 3104.1605(77) eV (2.5 ppm accuracy). This value is the most accurate, reference-free measurement done for such a transition and is in good agreement with recent QED predictions.

Guerra, M., F. Parente, P. Indelicato, and J. P. Santos. "Modified binary encounter Bethe model for electron-impact ionization." Int. J. Mass Spectrom. 313 (2012): 1. AbstractWebsite

Theoretical expressions for ionization cross sections by electron impact based on the binary encounter Bethe (BEB) model, valid from ionization threshold up to relativistic energies, are proposed.
The new modified BEB (MBEB) and its relativistic counterpart (MRBEB) expressions are simpler than the BEB (nonrelativistic and relativistic) expressions because they require only one atomic parameter, namely the binding energy of the electrons to be ionized, and use only one scaling term for the ionization of all sub-shells.
The new models are used to calculate the K-, L- and M-shell ionization cross sections by electron impact for several atoms with Z from 6 to 83. Comparisons with all, to the best of our knowledge, available experimental data show that this model is as good or better than other models, with less complexity.

Guimarães, D., M. L. Carvalho, M. Becker, A. von Bohlen, V. Geraldes, I. Rocha, and J. P. Santos. "Lead concentration in feces and urine of exposed rats by x-ray fluorescence and electrothermal atomic absorption spectrometry." X-Ray Spectrom. 41 (2012): 80. Abstract

n/a