Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG,
Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho
, Structural Concrete, Volume n/a, Number n/a, (2020)
AbstractAbstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.
Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG,
Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho
, Structural Concrete, Volume 22, Number 2, p.1147-1164, (2021)
AbstractAbstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.
Slab–column connection punching and ductility improvement methods for seismic response of buildings with flat slabs,
Isufi, Brisid, Almeida André, Marreiros Rui, Ramos António Pinho, and Lúcio Válter
, Structural Concrete, Volume 23, Number 3, p.1385 – 1398, (2022)
Abstractn/a
A state of the art of flat-slab frame tests for gravity and lateral loading,
Coronelli, Dario, Muttoni Aurelio, Pascu Ion R., Ramos Antonio P., and Netti Teresa
, Structural Concrete, Volume n/a, Number n/a, (2020)
AbstractAbstract This paper presents a critical review of the state of the art of experimental research concerning the seismic response of reinforced concrete flat slab frames. After a summary of tests on connections, the paper examines tests carried out on frames with gravity and cyclic lateral loading, and shake table tests; scaled specimens and one real scale study are included. A discussion of the results reached so far is provided focusing on the global response, the different load types and effects; the ultimate rotations at failure in relation to the gravity shear and a classification of different failure modes for different types of connections. Based on this analysis, the research needs are highlighted. An experimental program launched to address these open questions is described. Further open topics are highlighted.
Strengthening of flat slabs with post-tensioning using anchorages by bonding,
Faria, Duarte M. V., Lucio Valter J. G., and Ramos Pinho A.
, Engineering Structures, Volume 33, Number 6, p.2025–2043, (2011)
AbstractThis work aims to study a new flat slab strengthening technique based on post-tensioning with anchorages by bonding using an epoxy adhesive. The main advantages of this technique over the traditional prestress strengthening systems that use mechanical anchorages are that it does not need external permanent anchorages, meaning that the forces are introduced into the concrete gradually instead of being localized, thereby preserving aesthetics and useable space. The seven tested slab models show that this technique meets its objective as it is able to reduce reinforcement strains at service loads by up to 80{%} if the strengthening technique is applied in two directions and slab deformations by up to 70{%}, consequently making crack widths smaller. It can also increase punching load capacity by as much as 51{%} when compared to non-strengthened slabs. The results are compared with the EC2 (2004) [20], ACI 318-08 (2008) [23] and MC2010 (2010) [21] provisions. The main conclusions are that this strengthening technique is effective regarding ultimate and serviceability states and that it represents an advance in RC slab strengthening techniques. ?? 2011 Elsevier Ltd.
Strengthening of flat slabs with transverse reinforcement by introduction of steel bolts using different anchorage approaches,
Inácio, Micael M. G., Pinho Ramos A., Faria Duarte M. V., and Lúcio Válter J. G.
, Engineering Structures, nov, Volume 44, p.383–397, (2012)
AbstractThis work presents an experimental study concerning the post-punching behaviour of flat slabs strengthened with a new technique based on post-tensioning with anchorages by bonding using an epoxy adhesive. This strengthening technique proved efficient with respect to ultimate and serviceability states. Five slab specimens were tested in the post-punching range and it was found that the post-punching resistance was on average 78{%} of the punching resistance. This paper reports the development of strand forces and slab displacements from the beginning of the tests, including the bond stresses developed at several stages of the loading process. It was observed that top reinforcement bars were capable of transmitting post-punching loads to the prestressing strands. Taking this into account and based on the load bath envisaged from the column to the slab, expressions for the vertical load capacities corresponding to the parts of the load path are presented and compared with the experimental results, showing their ability to predict both ultimate loads and modes of failure. Compared with other strengthening techniques, the one proposed here not only upgrades ultimate and serviceability behaviour but also adds post-punching resistance, which is a great advantage in the event of progressive collapse, since it may avoid the collapse of an entire structure, thus reducing the risk of material and human losses.
Strengthening of RC slabs with reinforced concrete overlay on the tensile face,
Fernandes, Hugo, Lúcio Válter, and Ramos António
, Engineering Structures, Volume 132, p.540 - 550, (2017)
AbstractAbstract Strengthening of concrete structures with a new concrete layer has been commonly used for columns, beams and slabs. This technique is economic and efficient for structural strengthening since it uses the same base materials, steel and concrete. It is usually applied on the compressed face of the concrete element due to concrete’s recognized behaviour under compression, posing several challenges to control cracking and resistance when applied on the tensile face. For assessing the performance of the strengthening method, twelve slab specimens were designed and tested monotonically. The main parameters to assess in this work were the debonding behaviour and load, and the relationship between the latter and the relative displacements at the interface of the two concrete layers. The performance of the strengthened structures strongly relies on the interaction of the two concrete layers, with this being the main subject of the research about overlaid concrete. The load transfer capacity of the interface depends on the interface shear strength, which in turn is highly dependable on substrate roughness, cleanliness and curing conditions of the newly added layer. Interface performance may be improved by using steel connectors crossing the interface, properly anchored on both layers. The importance for these elements grows as the existing concrete is more deteriorated, since adhesion strength will decrease with lower quality concrete. This paper presents the experimental research for the application of bonded concrete overlays on the tensile face of reinforced concrete slabs, mainly aimed at office buildings and parking facilities, where spatial clearances or inaccessibility to the lower side of the slabs are recurrent. A ductile behaviour upon debonding was achieved for the specimens with reinforcement crossing the interface, and a debonding load up to three times that of the reference specimens without reinforcement crossing the interface.