Publications

Export 140 results:
Sort by: Author Title [ Type  (Asc)] Year
Journal Article
Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, (2019) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, Volume n/a, Number n/a, (2019) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, Volume 21, Number 2, p.501-516, (2020) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of thin lightly reinforced flat slabs under concentric loading, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Engineering Structures, Volume 196, p.109327, (2019) AbstractWebsite

The current research aims to study the behavior of thin reinforced concrete (RC) slabs under concentrated loads as well as to investigate the application of Critical Shear Crack Theory (CSCT) to such slabs. For this purpose, four square 100-mm-thick slabs were cast and subjected to concentrated punching monotonic loading. The experimental parameters were the flexural reinforcement ratio, 0.38% and 1.00%, and the presence or absence of shear headed stud reinforcement. It is shown that the failure criteria of CSCT describe reasonably well the observed failure modes and the ultimate loads of the specimens. However, attention is brought to some peculiarities in the analytical derivation of the load-rotation curve for thin lightly reinforced flat slabs, in which large deformations are experienced. Results showed that in such slabs, the behavior can be highly influenced by the post-yield stress-strain curve of the flexural steel reinforcement. As a result, the constitutive law of steel reinforcement should be explicitly taken into account in such cases. The versatility of CSCT to adapt to these conditions is demonstrated.

Behaviour of reinforced-concrete flat slabs with stirrups under reversed horizontal cyclic loading, Almeida, André F. O., Alcobia Bruno, Ornelas Miguel, Marreiros Rui, and Ramos António Pinho , Magazine of Concrete Research, Volume 72, Number 7, p.339-356, (2020) AbstractWebsite

This paper describes the experimental campaign to study the behaviour of reinforced-concrete flat slab structures with steel stirrups as punching shear reinforcement, under combined vertical and horizontal cyclic loading. The vertical load was first applied and kept constant during the test, while, regarding the cyclic horizontal loading, imposed cyclic drifts were increased until failure. Four slab specimens with shear reinforcement were tested and the results compared to a control slab specimen without shear reinforcement. The studied variables were different shear reinforcement ratios and the number of stirrup layers. The slabs were 4·15 × 1·85 m2 and 0·15 m thick, connected to two steel half-columns. The test setup used was developed by the research team and aimed to simulate the boundary conditions of a flat slab, representing the slab between middle spans in one direction and between zero bending moment points in the other direction. Results show that the use of steel stirrups as shear reinforcement is very effective, increasing shear, drift and energy dissipation capacities. The obtained results were also compared to the provisions given by European and American codes.

Comportamento Pós-Rotura de Lajes Fungiformes Pré Esforçadas, Ramos, António Pinho, and Lúcio Válter , Revista Portuguesa de Engenharia de Estruturas, Volume 1, Number Série II, p.5–14, (2007) Abstract

n/a

Damage and Diagnosis of Masonry Bridges-A Case Study, Rodrigues, Neuza, and Ramos António , 1st Historical Mortars Conference, Lisbon, (2008) AbstractWebsite

n/a

Deformation capacity evaluation for flat slab seismic design, Muttoni, A., Coronelli D., Lamperti Tornaghi M., Martinelli L., Pascu I. R., Pinho Ramos A., Tsionis G., Bamonte P., Isufi B., and Setiawan A. , Bulletin of Earthquake Engineering, Volume 20, Number 3, p.1619 – 1654, (2022) AbstractWebsite
n/a
Design for punching of prestressed concrete slabs, Clement, Thibault, Ramos Antonio Pinho, Ruiz Miguel Fernandez, and Muttoni Aurelio , Structural Concrete, Volume 14, Number 2, p.157–167, (2013) Abstract

n/a

Discussion of “Strengthening Two-Way Reinforced Concrete Floor Slabs Using Polypropylene Fiber Reinforcement” by Matthew J. Radik, Ece Erdogmus, and Travis Schafer, Faria, Duarte M. V., Lúcio Valtér J. G., and Pinho Ramos António M. , Journal of Materials in Civil Engineering, aug, Volume 25, Number 8, p.1142–1142, (2013) AbstractWebsite

n/a

Discussion: Pull-out and push-in tests of bonded steel strands, VIULA FARIA, Duarte M., LUCIO Válter J. G., Pinho Ramos A., and MARTI-VARGAS José R. , Magazine of concrete research, Volume 65, Number 17-18, p.1128–1131, (2013) AbstractWebsite

n/a

Eccentric punching strength of continuous flat slabs—Analysis of different experimental setups, Secci, Lorenzo, Lapi Massimo, Teoni Emanuele, Ramos Antonio Pinho, and Orlando Maurizio , Structural Concrete, Volume n/a, Number n/a, (2021) AbstractWebsite

Abstract This paper analyses the performance of the experimental setups to assess the punching strength of slab-column connections in continuous flat slabs under vertical and horizontal loading. In the last years, several experimental campaigns have been performed to investigate the punching strength of slab-column connections, but most of the experimental tests concerned isolated slab-column connections. Among the few setups aimed at reproducing the eccentric punching failure in continuous flat slabs, the setup developed at the NOVA School of Science and Technology in Lisbon is considered in this paper. The performance of the Lisbon setup is assessed through nonlinear finite element analyses, calibrated on experimental data, by comparison with numerical results of a theoretical continuous setup. Then, the performance of the isolated setups, used in many researches and at the base of some international codes, is also evaluated through the same finite element model. Numerical analyses highlight that the setup developed in Lisbon could provide reliable ultimate rotations of continuous flat slab connections, but it underestimates the punching strength. Despite isolated setups lead to similar results when compared with the Lisbon setup, the latter seems to provide a better representation of a continuous slab-column connection. The numerical analyses presented in this paper have been performed assuming monotonic lateral loading.

The effect of the vertical component of prestress forces on the punching strength of flat slabs, Ramos, Pinho A., Lúcio Válter J. G., and Faria Duarte M. V. , Engineering Structures, Volume 76, p.90–98, (2014) Abstract

The use of prestress in flat slabs is a common solution, mainly because it allows larger spans and thinner slabs. Nevertheless, smaller thicknesses near the slab-column connections, along with the superposition of high shear and flexural stresses, arise the question of the slab capacity to resist punching. The punching failure results from the superposition of shear and flexural stresses near the column, and is associated to the formation of a pyramidal plug of concrete which punches through the slab. It is a local and brittle failure. The use of prestress can increase the punching capacity of flat slabs-column connections.This work presents the experimental analysis of flat slab specimens with tendons under punching. Nine slabs were tested using unbonded prestress with high strength steel tendons. The influences on the punching capacity of the vertical component of the prestress forces resulting from inclined tendons near the column and their distance to the column are analysed. The in-plane compression force due to prestress was not applied to the slabs, in order to evaluate only the deviation force influence. This work aims to improve the understanding of the behaviour of prestressed flat slabs under punching load in order to properly evaluate the punching resistance of this kind of structures. The experimental punching loads are compared with the provisions of EC2, ACI 318-11 and MC2010. © 2014 Elsevier Ltd.

Experimental and parametric 3D nonlinear finite element analysis on punching of flat slabs with orthogonal reinforcement, Silva Mamede, Nuno F., Pinho Ramos A., and Faria Duarte M. V. , Engineering Structures, mar, Volume 48, p.442–457, (2013) AbstractWebsite

This work refers to experimental and 3D nonlinear FEA on punching. Numerical results were compared with experimental ones in order to benchmark the FE model and afterwards a parametric study was conducted, changing the reinforcement ratio, slab thickness, concrete strength and column dimensions, running a total of 360 models, where their effect on punching capacity is shown. EC2 and MC2010 provisions agreed approximately with experimental and FEA results. Based in the FEA results it is proposed an equation to predict the punching capacity with the introduction of fracture mechanics parameter, which was compared with several experimental results, giving good approximation.

Experimental and theoretical evaluation of punching strength of steel fiber reinforced concrete slabs, Gouveia, Nuno D., Lapi Massimo, Orlando Maurizio, Faria Duarte M. V., and Ramos António M. P. , Structural Concrete, Volume 19, Issue 1, Number 1, p.217-229, (2018) AbstractWebsite

This paper deals with the experimental and theoretical evaluation of punching shear capacity of steel fiber reinforced concrete (SFRC) slab–column connections. Five experimental specimens with a thickness of 160 mm, different fiber volume contents (0, 1.0, and 1.5%) and different flexural reinforcement ratios (0.75 and 1.5%) have been tested. The experimental results were evaluated using a physical–mechanical model based on the critical shear crack theory (CSCT). The model has given a good approximation of experimental punching shear strengths. In general, tests have highlighted a significant increase in load and deformation capacity of fiber reinforced concrete slab–column connections in comparison with reinforced concrete connections.

Flat slab strenghtening techniques against punching-shear, Lapi, M., Ramos A. P., and Orlando M. , Engineering Structures, Volume 180, p.160-180, (2019) AbstractWebsite

n/a

Flexural strengthening of flat slabs with FRP composites using EBR and EBROG methods, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Engineering Structures, Volume 211, p.110483, (2020) AbstractWebsite

One of the major disadvantages of conventional fibre-reinforced polymer (FRP) strengthening techniques is the premature debonding of the FRP, leading to an underutilization of the materials. The externally bonded reinforcement on grooves (EBROG) method, which has been proven successful in postponing debonding in several structural applications, is examined in this study for the first time for realistic conditions in flat slabs. To this end, two different layouts of the strengthening solution are tested under concentric monotonic loading: one representing roof-level slab-column connections in which carbon FRP (CFRP) sheets are laid on top of the joint region (cross layout); and another one representing intermediate floors, in which the aforementioned layout is not possible due to the presence of the column (grid layout). For each layout, two FRP bonding techniques are used: conventional externally bonded reinforcement (EBR) and EBROG. Another specimen, without FRP strengthening, is used as a reference. It is shown that the EBROG technique is effective in postponing debonding for both layouts. Compared to the specimens in which EBR was used, the load capacity was increased in case of EBROG by 36% when FRP sheets were bonded on top of the joint (cross layout) and by 15% when sheets were attached outside the joint region (grid layout). Debonding strains are shown to be significantly higher in the case of EBROG compared to EBR. The experimentally observed debonding strains were compared with code provisions and predictions of models from the literature. A simple calculation method giving reasonably good results for the load capacity of the FRP-strengthened specimens is presented.

A hybrid method for the calibration of finite element models of punching-shear in R/C flat slabs, Lapi, Massimo, Secci Lorenzo, Teoni Emanuele, Ramos Antonio Pinho, and Orlando Maurizio , Computers & Structures, Volume 238, p.106323, (2020) AbstractWebsite

The paper is focused on the calibration of non-linear 3D finite element (FE) analyses to simulate punching failure of R/C flat slabs. The calibration procedure is developed with reference to the code ABAQUS, which is one of the most used computer codes in nonlinear modelling of R/C structures. Generally, the calibration of a nonlinear FE model is grounded on one test only, so its reliability could be limited. Here a hybrid method for the calibration of FE models of R/C flat slabs failing in punching is proposed and discussed. The method consists in calibrating input data by comparison of finite element model (FEM) results with both experimental data and predictions provided by analytical models. The procedure allows for a consistent calibration to be performed, valid for a wide range of longitudinal reinforcement ratios, from 0.5% to 2.00%, and concrete grades, from C20/25 to C50/60. A case study is investigated using the proposed method. Results show that calibrated values of the fracture energy lie between those provided by Model Code 1990 and Model Code 2010. From the new calibration procedure, a relationship between fracture energy and concrete compressive strength is also derived and blind analyses are performed to check its reliability against experimental results.

Influence of flexural reinforcement on the seismic performance of flat slab – Column connections, Isufi, Brisid, Rossi Mariana, and Ramos António Pinho , Engineering Structures, Volume 242, (2021) AbstractWebsite
n/a
Influence of prestressing on the punching strength of post-tensioned slabs, Clement, Thibault, Ramos Antonio Pinho, Ruiz Miguel Fernandez, and Muttoni Aurelio , Engineering Structures, Volume 72, p.56–69, (2014) Abstract

Previous researches on punching of post-tensioned slabs have shown a number of phenomena significantly influencing their strength and behaviour. However, no general agreement is yet found on a physical theory (either in codes of practice or in design models) suitably describing the influence of prestressing and how should it be accounted on the punching shear behaviour. In this paper, the authors present the results of tests on 15 slabs (3000. ??. 3000. ??. 250. mm) tested to failure under different loading conditions. The aim of the tests was to investigate in a separate manner the different actions induced by prestressing on the punching shear strength (in-plane forces, bending moments and bonded tendons). These results are finally investigated on the basis of the physical model of the Critical Shear Crack Theory. The fundamentals of this theory are presented and adapted to post-tensioned slabs, providing a rational explanation of the observed phenomena and measured strengths. ?? 2014 Elsevier Ltd.

Influence of the top reinforcement detailing in the behaviour of flat slabs, Faria, Ricardo, Marreiros Rui, Ramos António Pinho, and Jesus Catarina , Structures, Volume 23, p.718 - 730, (2020) AbstractWebsite

This paper studies the influence of different longitudinal top reinforcement detailing on the behaviour and punching capacity of flat slabs. Experimental and numerical studies were carried out. The experimental campaign consisted in testing three reinforced concrete slabs 2.20 m wide with a thickness equal to 0.15 m. The numerical study was conducted using the non-linear finite element software ATENA 3D. Using numerical models, which were calibrated using the experimental tests, a parametric study was carried out to include other design solutions beyond the tested ones. The parameters that were changed in this parametric study were the steel reinforcement ratio, the concrete strength and the detailing of the top steel reinforcement, namely using a solution with uniform distribution and other with a higher concentration of reinforcement near the column. Finally, the results were compared with predictions obtained using some of the existing codes (Eurocode 2 and Model Code 2010). From this study it can be concluded that concentrating the top flexural reinforcement, keeping the same total amount of top longitudinal reinforcement, results in a stiffer response, an increment in the punching resistance, and a decrease in the maximum vertical displacement.

Nonlinear analysis of flat slab-column connections to optimize the use of HPFRC under monotonic vertical loading, Díaz, Rafael Sanabria, Isufi Brisid, Trautwein Leandro Mouta, and Ramos António Pinho , Structural Concrete, (2022) AbstractWebsite
n/a
On the efficiency of flat slabs strengthening against punching using externally bonded fibre reinforced polymers, Duarte, Duarte M., Einpaul Jurgen, Ramos António M., {Fernandez Ruiz} Miguel, and Muttoni Aurelio , Construction and Building Materials, Volume 73, p.366–377, (2014) Abstract

One possibility for strengthening existing flat slabs consists on gluing fibre reinforced polymers (FRPs) at the concrete surface. When applied on top of slab-column connections, this technique allows increasing the flexural stiffness and strength of the slab as well as its punching strength. Nevertheless, the higher punching strength is associated to a reduction on the deformation capacity of the slab-column connection, which can be detrimental for the overall behaviour of the structure (leading to a more brittle behaviour of the system). Design approaches for this strengthening technique are usually based on empirical formulas calibrated on the basis of the tests performed on isolated test specimens. However, some significant topics as the reduction on the deformation capacity or the influence of the whole slab (accounting for the reinforcement at mid-span) on the efficiency of the strengthening are neglected. In this paper, a critical review of this technique for strengthening against punching shear is investigated on the basis of the physical model proposed by the Critical Shear Crack Theory (CSCT). This approach allows taking into account the amount, layout and mechanical behaviour of the bonded FRP's in a consistent manner to estimate the punching strength and deformation capacity of strengthened slabs. The approach is first used to predict the punching strength of available test data, showing a good agreement. Then, it is applied in order to investigate strengthened continuous slabs, considering moment redistribution after concrete cracking and reinforcement yielding. This latter study provides valuable information regarding the differences between the behaviour of isolated test specimens and real strengthened flat slabs. The results show that empirical formulas calibrated on isolated specimens may overestimate the actual performance of FRP's strengthening. Finally, taking advantage of the physical model of the CSCT, the effect of the construction sequence on the punching shear strength is also evaluated, revealing the role of this issue which is also neglected in most empirical approaches.

Performance assessment of flat slabs strengthened with a bonded reinforced-concrete overlay, Lapi, M., Fernandes H., Orlando M., a Ramos, and Lúcio V. , Magazine of Concrete Research, Volume 70, Number 9, p.433-451, (2018) AbstractWebsite
n/a
A physical approach for considering how anchorage head size influences the punching capacity of slabs strengthened with vertical steel bolts, Silva, Ricardo, Faria Duarte Viúla M., Ramos Pinho A., and Inácio Micael , Structural Concrete, dec, Volume 14, Number 4, p.389–400, (2013) AbstractWebsite

n/a