Publications

Export 151 results:
Sort by: Author Title [ Type  (Desc)] Year
Journal Article
Punching of flat slabs with in-plane forces, Ramos, Pinho A., Lúcio Válter J. G., and Regan Paul E. , Engineering Structures, Volume 33, Number 3, p.894–902, (2011) AbstractWebsite

n/a

Punching of high strength concrete flat slabs without shear reinforcement, Inácio, Micael M. G., Almeida André F. O., Faria Duarte M. V., Lúcio Válter J. G., and Ramos António Pinho , Engineering Structures, nov, Volume 103, p.275–284, (2015) AbstractWebsite

The experimental research carried out to study the punching behavior of high strength concrete (HSC) flat slabs is reported in the present work. Three flat slab specimens were cast using HSC and another one with normal strength concrete (NSC), to be used as a reference slab. The HSC mix presented a compressive strength of about 130MPa, with a basalt coarse aggregate. The tested specimens were square with 1650mm side and 125mm thickness. The longitudinal reinforcement ratio varied between 0.94{%} and 1.48{%}. The experimental results show that the use of HSC led to a significant load capacity increase when compared with the reference model made with NSC. Furthermore, the experimental results also indicated that as the longitudinal reinforcement ratio increased, the punching capacity also increased. The results obtained in this set of experimental tests and others collected from the literature were compared with the code provisions by EC2, MC2010 and ACI 318-11.

Punching of reinforced concrete flat slabs – Rational use of high strength concrete, Inácio, Micael M. G., Lapi Massimo, and Ramos Antonio Pinho , Engineering Structures, Volume 206, p.110194, (2020) AbstractWebsite

This paper deals with punching of reinforced high strength concrete (HSC) flat slabs. Despite the use of HSC increased significantly in the last years, the experimental research on punching behavior of HSC slabs is still limited. Furthermore, most of this past research adopted concrete compressive strength lower than 90 MPa. In a previous work by this research group three specimens with concrete compressive strength around 120 MPa and one with normal strength concrete (NSC) were tested. The present work represents the continuation of the previous activity and it is focused on the rational use of HSC. Four specimens with HSC and one of NSC were tested under monotonic vertical loading. The HSC was placed only in the slab-column connection region and it was limited to a thin layer in the compressive zone, in order to have a more economical and sustainable solution. This rational use of the HSC showed excellent results in terms of punching strength. Limiting the HSC to a thin layer in the compressive zone resulted in an almost equal punching strength to that obtained with the slab entirely casted in HSC.

Punching of Strengthened Concrete Flat Slabs—Experimental Analysis and Comparison with Codes, Duarte, Faria, Micael Inácio, Válter Lúcio, and António Ramos , Structural Engineering International, may, Volume 22, Number 2, p.202–214, (2012) AbstractWebsite

n/a

Punching shear behaviour of full-scale slab-column connections cast from concrete with coarse recycled aggregate, Fecko, Tadeáš, Kormošová Ľudmila, Ramos António Pinho, and Halvonik Jaroslav , Engineering Structures, Volume 345, (2025) AbstractWebsite
n/a
Punçoamento em lajes de betão com fibras de aço, Gouveia, N. D., Faria D. M. V., and Ramos A. M. P. , Revista Internacional TECH ITT by Construlink, Volume 11, (2013) Abstract

n/a

Punçoamento em Lajes Fungiformes Reforçadas com Parafusos Transversais Aderentes (Parte 1), Gomes J. e Ramos, A. P. , Revista Internacional Construlink, Volume 30, p.23–33, (2012) Abstract

n/a

Punçoamento em Lajes Fungiformes Reforçadas com Parafusos Transversais Aderentes (Parte 2), Gomes J. e Ramos, A. P. , Revista Internacional Construlink, Volume 10, Number 30, p.34–43, (2012) Abstract

n/a

Rational Use of High-Strength Concrete in Flat Slab- Column Connections under Seismic Loading, and Micael Inácio, Brisid Isufi, Massimo Lapi António Pinho Ramos , Volume 117, Issue 6, (2020) Abstract

High-strength concrete (HSC) slab-column connections with relatively low concrete strengths compared to today’s capabilities have been tested under seismic-type loading in the past. Herein, the hybrid use of HSC with compressive strength approximately 120 MPa and normal-strength concrete (NSC) is investigated through three reversed horizontal cyclic-loading tests with different geometries of the HSC region and a reference NSC specimen. The results show that HSC applied in the vicinity of the column can significantly enhance the seismic performance of slab-column connections. The best result in terms of drift capacity and economic use of HSC was achieved in the case of full-depth HSC extended from the column’s face up to 2.5 times the effective depth. Drift ratios up to 3.0% were achieved. A comparison with previous tests showed that the hybrid use of HSC and NSC can achieve similar results to the provision of punching shear reinforcement.

Rational use of HPFRC in slab – column connections under reversed horizontal cyclic loading, Ramos, António, Isufi Brisid, Marreiros Rui, Bolešová Mária, and Gajdošová Katarina , Engineering Structures, Volume 270, (2022) AbstractWebsite
n/a
Reforço ao punçoamento de lajes fungiformes com lâmina complementar de betão, Fernandes, Hugo, Lúcio Válter, and Ramos António , Revista Portuguesa de Engenharia de Estruturas, Volume III, Issue 5, p.63-72, (2017)
Reforço de lajes fungiformes com armadura transversal pós-instalada usando diferentes técnicas de ancoragem, Inácio, Micael, Ramos António, and Faria Duarte , Revista Portuguesa de Engenharia de Estruturas, Volume III, Number 3, p.63–74, (2017) Abstract

n/a

Resistência ao Punçoamento de Lajes Fungiformes Pré-Esforçadas - Método Alternativo de Cálculo, Ramos, António, and Lúcio Válter , Revista Internacional Construlink, Volume 4, p.4–14, (2006) Abstract

n/a

Reversed horizontal cyclic loading tests of flat slab specimens with studs as shear reinforcement, Isufi, Brisid, Ramos António Pinho, and Lúcio Válter , Structural Concrete, (2018) AbstractWebsite

The results of a series of experiments on four reinforced concrete flat slab specimens with shear studs and a control specimen without any shear reinforcement are presented. The specimens were tested under constant gravity loads and reversed horizontal cyclic displacements. The main test variables were the applied gravity load and the number of perimeters of studs. One of the specimens was tested in two phases to study the postearthquake behavior. Results showed a considerable improvement of the deformation capacity of specimens with studs compared to the reference specimen. In agreement with previous research, increasing the applied gravity shear ratio resulted in a lower experimental drift capacity. It is shown that a better explanation of the observed ultimate drifts can be made by considering also the flexural capacity and the extent of shear reinforcement. The specimen tested in two phases exhibited considerable residual capacity, even after severe horizontal loading.

Reversed horizontal cyclic loading tests of flat slab specimens with studs as shear reinforcement, Isufi, Brisid, Ramos António Pinho, and Lúcio Válter , Structural Concrete, Volume 20, Number 1, p.330-347, (2019) AbstractWebsite

The results of a series of experiments on four reinforced concrete flat slab specimens with shear studs and a control specimen without any shear reinforcement are presented. The specimens were tested under constant gravity loads and reversed horizontal cyclic displacements. The main test variables were the applied gravity load and the number of perimeters of studs. One of the specimens was tested in two phases to study the postearthquake behavior. Results showed a considerable improvement of the deformation capacity of specimens with studs compared to the reference specimen. In agreement with previous research, increasing the applied gravity shear ratio resulted in a lower experimental drift capacity. It is shown that a better explanation of the observed ultimate drifts can be made by considering also the flexural capacity and the extent of shear reinforcement. The specimen tested in two phases exhibited considerable residual capacity, even after severe horizontal loading.

A review of punching behavior of slab–column connections with recycled coarse aggregate concrete, Ramos, António, Marchão Carla, Pacheco João Nuno, Enfedaque Alejandro, Coronelli Dario, Faria Duarte, de Brito Jorge, Ruiz Miguel Fernández, and Marreiros Rui , Structural Concrete, Volume 26, Number 2, p.1388 – 1401, (2025) AbstractWebsite
n/a
A review of tests on slab-column connections with advanced concrete materials, Isufi, Brisid, and Ramos António Pinho , Structures, Volume 32, p.849-860, (2021) AbstractWebsite

Advances in concrete technology during the last decades have resulted in the development of materials with enhanced mechanical properties, such as High Strength Concrete (HSC), Fibre Reinforced Concrete (FRC) and Ultra-High Performance Fibre Reinforced Concrete (UHPFRC). The application of these materials in flat slabs, which are a popular structural solution in Reinforced Concrete (RC) buildings worldwide, has the potential of significantly reducing raw material consumption by enabling the design of slenderer and therefore lighter structures. However, flat slabs are susceptible to punching shear failure, which is a complex phenomenon that remains challenging, even though significant efforts have been made to experimentally study it. For advanced concrete materials (HSC, FRC and UHPFRC), the challenge is further accentuated by the continuous and rapid development of these materials. With the purpose of identifying and highlighting gaps in the published literature, a review of tests with HSC, FRC and UHPFRC slab-column connections in non-seismic and seismic loading applications is presented in this paper. It is shown that future research directions in this field include, among others, testing thicker slabs, HSC slabs with higher concrete compressive strength, HSC combined with FRC and several more cases related to seismic loading conditions.

Role of punching shear reinforcement in the seismic performance of flat slab frames, Isufi, B., Cismasiu I., Marreiros R., Pinho Ramos A., and Lúcio V. , Engineering Structures, Volume 207, (2020) AbstractWebsite
n/a
Seismic Performance of Reinforced Concrete Buildings with Joist and Wide-Beam Floors during the 26 November 2019 Albania Earthquake, Baballëku, Markel, Isufi Brisid, and Ramos António Pinho , Buildings, Volume 13, Number 5, (2023) AbstractWebsite
n/a
Seismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test, Ramos, António Pinho, Isufi Brisid, Marreiros Rui, Coronelli Dario, Netti Teresa, Lamperti Tornaghi Marco, Tsionis Georgios, and Muttoni Aurelio , Journal of Earthquake Engineering, Volume 27, Number 9, p.2299 – 2318, (2023) AbstractWebsite
n/a
SFRC flat slabs punching behaviour - Experimental research, Gouveia, Nuno D., Fernandes Nelson A. G., Faria Duarte M. V., Ramos António M. P., and Lúcio Válter J. G. , Composites Part B: Engineering, Volume 63, p.161–171, (2014) Abstract

The use of randomly distributed steel fibres in the concrete mix improves its mechanical properties. In the particular case of a flat slab-column connection, this solution can provide slabs with an increased load capacity and deformation capacity, allowing a potential reduction of reinforcement. This work presents the experimental study of the behaviour of SFRC flat slabs up to failure under a concentrated loading, accompanied by the study of the mechanical properties of the SFRC, which consisted in three-point loading notched beams, compression and splitting tests. In this study, the hooked end steel fibre dosages varied between 0{%} and 1.25{%} by volume. Test results showed that the inclusion of steel fibres influences both slab stiffness and its load capacity. Increments of load capacity up to 64{%} were obtained in slabs with SFRC compared with the reference slab without fibres. The experimental results were compared with the predictions provided by several existing models. © 2014 Elsevier Ltd. All rights reserved.

Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Structural Concrete, Volume n/a, Number n/a, (2020) AbstractWebsite

Abstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.

Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Structural Concrete, Volume 22, Number 2, p.1147-1164, (2021) AbstractWebsite

Abstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.

Slab–column connection punching and ductility improvement methods for seismic response of buildings with flat slabs, Isufi, Brisid, Almeida André, Marreiros Rui, Ramos António Pinho, and Lúcio Válter , Structural Concrete, Volume 23, Number 3, p.1385 – 1398, (2022) AbstractWebsite
n/a
A state of the art of flat-slab frame tests for gravity and lateral loading, Coronelli, Dario, Muttoni Aurelio, Pascu Ion R., Ramos Antonio P., and Netti Teresa , Structural Concrete, Volume n/a, Number n/a, (2020) AbstractWebsite

Abstract This paper presents a critical review of the state of the art of experimental research concerning the seismic response of reinforced concrete flat slab frames. After a summary of tests on connections, the paper examines tests carried out on frames with gravity and cyclic lateral loading, and shake table tests; scaled specimens and one real scale study are included. A discussion of the results reached so far is provided focusing on the global response, the different load types and effects; the ultimate rotations at failure in relation to the gravity shear and a classification of different failure modes for different types of connections. Based on this analysis, the research needs are highlighted. An experimental program launched to address these open questions is described. Further open topics are highlighted.