Punching behavior of slab-column connections with recycled coarse aggregate concrete, Ramos, António Pinho, Marchão Carla, Marreiros Rui, Domingues Manuel, and Cardoso Tainara , fib Symposium, p.2106 – 2115, (2025) Abstract
n/a
Punching of prestressed flat slabs: Experimental analysis, Ramos, A. M. P., and Lúcio V. J. G. , International Workshop on Punching Shear Capacity of RC Flat Slabs, Volume 57, Stockholm, p.441–448, (2000) Abstract

The experimental analysis of nine prestressed flat slab models under punching is described and the results are compared with the recommendations of EC2 and MC90. The tests were performed on specimens at a scale 1/3, prestressed with unbonded high strength steel. In the first set, the specimens (AR2 to AR5 and AR7) were only subjected to in-plane compression, to evaluate the effect of the in-plane forces on the punching resistance. The second set of tests (AR8 to AR11) intended to study the effect of the vertical component of the tendon forces near the column in the punching resistance. This work aims to improve the understanding of the behaviour of prestressed flat slabs under punching load and the evaluation of the punching resistance.

Punçoamento em Lajes Fungiformes Pré-Esforçadas, Ramos, António , IST-UTL, Lisbon, (2003) Abstract

n/a

Punching of Flat Slabs under Reversed Horizontal Cyclic Loading, Ramos, António, Marreiros Rui, Almeida André, Isufi Brisid, and Inácio Micael , ACI Fall Convention 2016, Philadelphia, (2016) Abstract

Flat slab structures are a very common structural solution nowadays, due to their architectural and economic advantages. However, flat slab-column connections may be vulnerable to punching failure, especially in an event of an earthquake, with potentially high human and economic losses. This type of structural solution is adequately covered by design codes and recommendations in North America, due to a large amount of experimental research carried out. In Europe the situation is different, missing specific guidance to flat slab design under earthquake action in most European codes. The ACI 318-14 prescriptive approach to the gravity shear ratio-drift ratio relationship shows good agreement with experimental results. Following a similar approach and, based in a databank containing cyclic horizontally loaded tests of slab-column connections found in literature, proposals are made applicable to EC2 and MC2010.

S
A physical approach for considering how anchorage head size influences the punching capacity of slabs strengthened with vertical steel bolts, Silva, Ricardo, Faria Duarte Viúla M., Ramos Pinho A., and Inácio Micael , Structural Concrete, dec, Volume 14, Number 4, p.389–400, (2013) AbstractWebsite

n/a