Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading,
Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui
, Structural Concrete, Volume 21, Number 2, p.501-516, (2020)
AbstractAbstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.
Behaviour of reinforced-concrete flat slabs with stirrups under reversed horizontal cyclic loading,
Almeida, André F. O., Alcobia Bruno, Ornelas Miguel, Marreiros Rui, and Ramos António Pinho
, Magazine of Concrete Research, Volume 72, Number 7, p.339-356, (2020)
AbstractThis paper describes the experimental campaign to study the behaviour of reinforced-concrete flat slab structures with steel stirrups as punching shear reinforcement, under combined vertical and horizontal cyclic loading. The vertical load was first applied and kept constant during the test, while, regarding the cyclic horizontal loading, imposed cyclic drifts were increased until failure. Four slab specimens with shear reinforcement were tested and the results compared to a control slab specimen without shear reinforcement. The studied variables were different shear reinforcement ratios and the number of stirrup layers. The slabs were 4·15 × 1·85 m2 and 0·15 m thick, connected to two steel half-columns. The test setup used was developed by the research team and aimed to simulate the boundary conditions of a flat slab, representing the slab between middle spans in one direction and between zero bending moment points in the other direction. Results show that the use of steel stirrups as shear reinforcement is very effective, increasing shear, drift and energy dissipation capacities. The obtained results were also compared to the provisions given by European and American codes.