Publications

Export 30 results:
Sort by: [ Author  (Desc)] Title Type Year
A B C D E F G H I J K L M N O P Q [R] S T U V W X Y Z   [Show ALL]
R
Seismic behavior of slab-column connections with varying flexural reinforcement ratio, Rossi, Mariana, Isufi Brisid, and Ramos António Pinho , fib Symposium, Volume 2021-June, p.987 – 994, (2021) Abstract
n/a
Reabilitação de Pontes Históricas de Alvenaria – Um Caso de Estudo, Rodrigues, Neuza, and Ramos António , ASCP'09 – 1º Congresso de Segurança e Conservação de Pontes ASCP, Lisbon, (2009) Abstract

n/a

Damage and Diagnosis of Masonry Bridges-A Case Study, Rodrigues, Neuza, and Ramos António , 1st Historical Mortars Conference, Lisbon, (2008) AbstractWebsite

n/a

Gestão de Pontes Classificadas de Alvenaria inseridas na Rede Rodoviária Nacional, Rodrigues, Neuza, and Ramos António , ASCP 2011 – 2º Congresso Segurança e Conservação de Pontes, Coimbra, (2011) Abstract

n/a

As obras de arte classificadas sob jurisdição da EP – Estradas de Portugal S.A.-Metodologias de manutenção e reabilitação, Rodrigues, Neuza, and Ramos António , CIRea2012 – Conferência Internacional sobre Reabilitação de Estruturas Antigas de Alvenaria, Lisbon, (2012) Abstract

n/a

Numerical analysis of fire-induced effects on load carrying capacity of slab-column connections under unbalanced moments, de Randi, Ricardo Paula, Fanton Andreia Romero, Trautwein Leandro Mouta, de Almeida Luiz Carlos, and Ramos António Pinho , fib Symposium, p.68 – 77, (2025) Abstract
n/a
Safety on Punching of Prestressed Flat Slabs, Ramos, António, and Lúcio Valter , fib congress 2006, Naples, (2006) Abstract

n/a

Seismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test, Ramos, António Pinho, Isufi Brisid, Marreiros Rui, Coronelli Dario, Netti Teresa, Lamperti Tornaghi Marco, Tsionis Georgios, and Muttoni Aurelio , Journal of Earthquake Engineering, Volume 27, Number 9, p.2299 – 2318, (2023) AbstractWebsite
n/a
Punching of Flat Slabs under Reversed Horizontal Cyclic Loading, Ramos, António, Marreiros Rui, Almeida André, Isufi Brisid, and Inácio Micael , ACI Fall Convention 2016, Philadelphia, (2016) Abstract

Flat slab structures are a very common structural solution nowadays, due to their architectural and economic advantages. However, flat slab-column connections may be vulnerable to punching failure, especially in an event of an earthquake, with potentially high human and economic losses. This type of structural solution is adequately covered by design codes and recommendations in North America, due to a large amount of experimental research carried out. In Europe the situation is different, missing specific guidance to flat slab design under earthquake action in most European codes. The ACI 318-14 prescriptive approach to the gravity shear ratio-drift ratio relationship shows good agreement with experimental results. Following a similar approach and, based in a databank containing cyclic horizontally loaded tests of slab-column connections found in literature, proposals are made applicable to EC2 and MC2010.

Post-punching behaviour of prestressed concrete flat slabs, Ramos, Pinho A., and Lúcio V. J. G. , Magazine of Concrete Research, Volume 60, Number 4, p.245–251, (2008) AbstractWebsite

The progressive collapse of structures generally results in the loss of human lives. Experience shows that flat slab structures are very sensitive to progressive collapse, which may cause serious accidents if special detailing is not provided. The post-punching behaviour of a column-supported slab is decisive in the progressive collapse development. This work presents the experimental research carried out to study the post-punching behaviour of prestressed concrete flat slabs. Six reduced-scale prestressed concrete flat slab models were tested. The tests were carried out in two different phases. In the first phase the models were loaded up to failure by punching. Afterwards, the models were loaded again to study the post-punching behaviour changes caused by the presence of unbonded, prestressed tendons and the influences of their distance to the column.

Análise Experimental de Técnicas de Reparação e Reforço ao Punçoamento, Ramos, A. M. P. e Lúcio, V. , 5º Encontro Nacional sobre Estruturas Pré-esforçadas, Porto, (1994) Abstract

n/a

Punching behavior of slab-column connections with recycled coarse aggregate concrete, Ramos, António Pinho, Marchão Carla, Marreiros Rui, Domingues Manuel, and Cardoso Tainara , fib Symposium, p.2106 – 2115, (2025) Abstract
n/a
Punçoamento em Lajes Fungiformes Pré-Esforçadas, Ramos, António , IST-UTL, Lisbon, (2003) Abstract

n/a

Project RecycleSlab - Structural Behaviour of Recycled Aggregate Reinforced Concrete Flat Slabs with Drop Panels Under Seismic and Cyclic Actions, Ramos, António, Marchão Carla, Coronelli Dario, Faria Duarte, Fiorillo Fausta, Rosati Gianpaolo, Halvonik Jaroslav, de Almeida João Pacheco, de Brito Jorge, Martinelli Luca, Lamperti Marco, Ruiz Miguel Fernandez, Lavagna Monica, Vollum Robert, and Marreiros Rui , Lecture Notes in Civil Engineering, Volume 718 LNCE, p.206 – 216, (2025) AbstractWebsite
n/a
HYBRID USE OF HPFRC IN SLAB – COLUMN CONNECTIONS UNDER CYCLIC LATERAL LOADING, Ramos, António Pinho, Isufi Brisid, Marreiros Rui, and Marchão Carla , fib Symposium, p.1880 – 1889, (2022) Abstract
n/a
Repair and Strengthening Methods of Flat Slabs for Punching, Ramos, Antonio, Lucio Valter, and Regan Paul E. , International Workshop on Punching Shear Capacity of RC Flat Slabs, Stockholm, p.125–133, (2000) Abstract

The present work reports experimental research carried out on repair and strengthening methods of flat slabs for punching. The repair and strengthening methods studied are: strengthening using transversal prestress, repair by substitution of the damaged concrete; and strengthening using steel beams as a column head, connected to the column and to the slab with epoxy resin and mechanical expansion anchors. Four experimental test slabs (AR1 to AR4) were produced and tested: two with transversal prestress, one only repaired and one strengthened with a steel column head. The execution process, its efficiency and design, are discussed.

Comportamento de Lajes Fungiformes Sujeitas a Acções Horizontais Cíclicas, Ramos, António Pinho , Construção Magazine, Issue 76, p.44-45, (2016)
Punching of flat slabs with in-plane forces, Ramos, Pinho A., Lúcio Válter J. G., and Regan Paul E. , Engineering Structures, Volume 33, Number 3, p.894–902, (2011) AbstractWebsite

n/a

Reforço de Lajes Fungiformes ao Punçoamento com Perfis Metálicos, Ramos, A. M. P. e Lúcio, V. , 6º Encontro Nacional sobre Estruturas Pré-esforçadas, Lisbon, (1996) Abstract

n/a

Numerical analysis of the effects of corrosion on the punching shear capacity of reinforced concrete flat slabs with openings, Ramos, Vinícius D'Almeida Rodrigues, Trautwein Leandro Mouta, Ramos António Pinho, and Liberati Elyson Andrew Pozo , Structural Concrete, (2025) AbstractWebsite
n/a
Resistência ao Punçoamento de Lajes Fungiformes Pré-Esforçadas - Método Alternativo de Cálculo, Ramos, António, and Lúcio Válter , Revista Internacional Construlink, Volume 4, p.4–14, (2006) Abstract

n/a

A review of punching behavior of slab–column connections with recycled coarse aggregate concrete, Ramos, António, Marchão Carla, Pacheco João Nuno, Enfedaque Alejandro, Coronelli Dario, Faria Duarte, de Brito Jorge, Ruiz Miguel Fernández, and Marreiros Rui , Structural Concrete, Volume 26, Number 2, p.1388 – 1401, (2025) AbstractWebsite
n/a
Punching Research at Universidade Nova de Lisboa, a Ramos, Lúcio V., Faria D., and Inácio M. , Design Of Concrete Structures and Bridges Using Eurocodes, Bratislava, (2011) Abstract

n/a

Rational use of HPFRC in slab – column connections under reversed horizontal cyclic loading, Ramos, António, Isufi Brisid, Marreiros Rui, Bolešová Mária, and Gajdošová Katarina , Engineering Structures, Volume 270, (2022) AbstractWebsite
n/a
Punching of prestressed flat slabs: Experimental analysis, Ramos, A. M. P., and Lúcio V. J. G. , International Workshop on Punching Shear Capacity of RC Flat Slabs, Volume 57, Stockholm, p.441–448, (2000) Abstract

The experimental analysis of nine prestressed flat slab models under punching is described and the results are compared with the recommendations of EC2 and MC90. The tests were performed on specimens at a scale 1/3, prestressed with unbonded high strength steel. In the first set, the specimens (AR2 to AR5 and AR7) were only subjected to in-plane compression, to evaluate the effect of the in-plane forces on the punching resistance. The second set of tests (AR8 to AR11) intended to study the effect of the vertical component of the tendon forces near the column in the punching resistance. This work aims to improve the understanding of the behaviour of prestressed flat slabs under punching load and the evaluation of the punching resistance.