Publications

Export 43 results:
Sort by: Author Title [ Type  (Asc)] Year
Conference Paper
Análise do efeito de características mecânicas e geométricas que afetam o comportamento ao Punçoamento de lajes fungiformes, Mamede, Nuno, Ramos António, and Faria Duarte , Encontro Nacional Betão Estrutural 2012, Porto, p.1–8, (2012) Abstract

n/a

Comparison of flat slab strengthening techniques against punching-shear, Lapi, Massimo, Martini Daniele, Zagli Emilio, Orlando Maurizio, Ramos Antonio, and Spinelli Paolo , Proceedings of The New Boundaries of Structural Concrete 2016, NBSC2016, Italy ACI Chapter, Capri, Italy, (2016) Abstract

Punching-shear capacity of slab-column connections in existing R/C structures may be inadequate to bear design loads, so strengthening works are required. The lack of punching resistance may be due to detailing, design or building errors; in other cases, such lack is due to a change of use, which requires an increase of resistance. Different techniques have been developed for strengthening R/C slabs against punching: enlargement of the support, gluing external fibre reinforced polymers or casting a bonded concrete overlay (BCO) on the slab's top surface, insertion of post-installed steel bolts, application of fibre reinforced polymers cords as shear reinforcement. In the paper, the authors apply the Critical Shear Crack Theory (CSCT) to all of these techniques and evaluate their efficacy with reference to a case study.

Efeito do confinamento e da redistribuição de momentos no comportamento de lajes fungiformes, Faria, Ricardo, Marreiros Rui, Ramos António, and Antunes Gonçalo , Encontro Nacional Betão Estrutural 2018, 7-9 Nov., LNEC, Lisboa, (2018)
EXPERIMENTAL INVESTIGATION ON THE BEHAVIOUR OF HYBRID HPFRC FLAT SLABS, Isufi, Brisid, Marchão Carla, Marreiros Rui, and Ramos António Pinho , fib Symposium, p.1870 – 1879, (2022) Abstract
n/a
Flat Plate Building and Frame Full Scale Tests for European Design Provisions, Coronelli, Dario, Muttoni Aurelio, Pascu Radu, and Ramos Antonio , American Concrete Institute, ACI Special Publication, Volume SP-353, p.73 – 96, (2022) Abstract
n/a
Flat slab structural response for seismic european design. Full scale testing results, Coronelli, Dario, Martinelli Luca, Muttoni Aurelio, Pascu Radu, and Ramos Antonio , fib Symposium, Volume 2021-June, p.1831 – 1839, (2021) Abstract
n/a
Flat slab structural response for seismic european design. Full scale testing results, Coronelli, Dario, Martinelli Luca, Muttoni Aurelio, Pascu Radu, and Ramos Antonio , fib Symposium, Volume 2021-June, p.1831 – 1839, (2021) Abstract
n/a
HYBRID USE OF HPFRC IN SLAB – COLUMN CONNECTIONS UNDER CYCLIC LATERAL LOADING, Ramos, António Pinho, Isufi Brisid, Marreiros Rui, and Marchão Carla , fib Symposium, p.1880 – 1889, (2022) Abstract
n/a
Influência da distribuição transversal de armaduras longitudinais junto ao pilar na resistência ao punçoamento, Faria, Ricardo, Jesus Catarina, Marreiros Rui, and Ramos António , Encontro Nacional Betão Estrutural 2018, 7-9 Nov., LNEC, Lisboa, (2018)
Punching of Flat Slabs under Reversed Horizontal Cyclic Loading, Ramos, António, Marreiros Rui, Almeida André, Isufi Brisid, and Inácio Micael , ACI Fall Convention 2016, Philadelphia, (2016) Abstract

Flat slab structures are a very common structural solution nowadays, due to their architectural and economic advantages. However, flat slab-column connections may be vulnerable to punching failure, especially in an event of an earthquake, with potentially high human and economic losses. This type of structural solution is adequately covered by design codes and recommendations in North America, due to a large amount of experimental research carried out. In Europe the situation is different, missing specific guidance to flat slab design under earthquake action in most European codes. The ACI 318-14 prescriptive approach to the gravity shear ratio-drift ratio relationship shows good agreement with experimental results. Following a similar approach and, based in a databank containing cyclic horizontally loaded tests of slab-column connections found in literature, proposals are made applicable to EC2 and MC2010.

Punching of High Strength Concrete Flat Slabs - Experimental Investigation, Micael Inácio, António Ramos, Válter Lúcio, and Faria Duarte , fib symposium Tel Aviv 2013, Tel Aviv, p.377–380, (2013) Abstract

n/a

Punçoamento em Lajes Fungiformes de Betão de Elevada Resistência – Estudo Experimental, e Micael Inácio, Duarte Faria, Válter Lúcio António Ramos , 5ªs Jornadas Portuguesas de Engenharia de Estruturas, Encontro Nacional de Betão Estrutural 2014, 9º Congresso Nacional de Sismologia e Engenharia Sísmica, Lisbon, (2014) Abstract

n/a

Resposta da ligação pilar-laje fungiforme sujeitas a ações horizontais cíclicas reforçadas com estribos, Almeida, André, Ramos António, Marreiros Rui, Lúcio Válter, and Faria Ricardo , Encontro Nacional Betão Estrutural 2018, 7-9 Nov., LNEC, Lisboa, (2018)
SEISMIC BEHAVIOR OF SLAB–COLUMN CONNECTIONS USING HIGH PERFORMANCE FIBER REINFORCED CONCRETES, Ramos, António, Isufi Brisid, and Marreiros Rui , American Concrete Institute, ACI Special Publication, Volume SP-357, p.123 – 138, (2023) Abstract
n/a
Seismic behaviour of slab-column connections with various punching shear enhancement methods, Isufi, Brisid, Marreiros Rui, Ramos António Pinho, and Lúcio Válter , fib Symposium, Volume 2021-June, p.978 – 986, (2021) Abstract
n/a
STRENGTHENING OF FLAT SLABS WITH FIBRE REINFORCED POLYMERS USING THE EXTERNALLY BONDED REINFORCEMENT ON GROOVES METHOD: A REVIEW, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , REHABEND, p.1946 – 1953, (2022) Abstract
n/a
Journal Article
Análise Numérica Não Linear do Punçoamento em Lajes Fungiformes – Calibração, Mamede, Nuno, Faria Duarte, and Ramos António , Revista Internacional Tech ITT, Volume 12, Issue 35, p.4-13, (2014)
Análise Numérica Não Linear do Punçoamento em Lajes Fungiformes – Estudo Paramétrico, Mamede, Nuno, Faria Duarte, and Ramos António , Revista Internacional Tech ITT, Volume 12, Issue 35, p.14-24, (2014)
Applied element method simulation of experimental failure modes in RC shear walls, Cismasiu, Corneliu, Ramos António Pinho, Moldovan Ionut D., Ferreira Diogo F., and Filho Jorge B. , Computers and Concrete, Volume 19, Issue 4, p.365–374, (2017) Abstract

n/a

Behavior of flat slabs with partial use of high-performance fiber reinforced concrete under monotonic vertical loading, Isufi, Brisid, Relvas João Pedro, Marchão Carla, and Ramos António Pinho , Engineering Structures, Volume 264, (2022) AbstractWebsite
n/a
Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, (2019) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, Volume n/a, Number n/a, (2019) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of RC flat slabs with shear bolts under reversed horizontal cyclic loading, Almeida, André F. O., Ramos António P., Lúcio Válter, and Marreiros Rui , Structural Concrete, Volume 21, Number 2, p.501-516, (2020) AbstractWebsite

Abstract An experimental work on reinforced concrete flat slab specimens to test the efficiency of postinstalled bolts, as punching shear reinforcement in resisting vertical and cyclic horizontal loads, was conducted and is presented in this paper. The test protocol consisted in increasing horizontal drifts combined with constant vertical load until failure. Two different detailing solutions for the shear reinforcement were considered, one using a radial distribution around the column and another using a cross distribution, being the results compared with a previously tested reference specimen. The dimensions of the specimens were 4.25 x 1.85 x 0.15 m3. The test setup used for these tests was developed by the research team and simulates the boundary conditions with already recognized good results. Postinstalled steel bolts were proven to be an efficient solution for strengthening of existing structures, improving the structural behavior, and the punching resistance.

Behavior of thin lightly reinforced flat slabs under concentric loading, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Engineering Structures, Volume 196, p.109327, (2019) AbstractWebsite

The current research aims to study the behavior of thin reinforced concrete (RC) slabs under concentrated loads as well as to investigate the application of Critical Shear Crack Theory (CSCT) to such slabs. For this purpose, four square 100-mm-thick slabs were cast and subjected to concentrated punching monotonic loading. The experimental parameters were the flexural reinforcement ratio, 0.38% and 1.00%, and the presence or absence of shear headed stud reinforcement. It is shown that the failure criteria of CSCT describe reasonably well the observed failure modes and the ultimate loads of the specimens. However, attention is brought to some peculiarities in the analytical derivation of the load-rotation curve for thin lightly reinforced flat slabs, in which large deformations are experienced. Results showed that in such slabs, the behavior can be highly influenced by the post-yield stress-strain curve of the flexural steel reinforcement. As a result, the constitutive law of steel reinforcement should be explicitly taken into account in such cases. The versatility of CSCT to adapt to these conditions is demonstrated.

Behaviour of reinforced-concrete flat slabs with stirrups under reversed horizontal cyclic loading, Almeida, André F. O., Alcobia Bruno, Ornelas Miguel, Marreiros Rui, and Ramos António Pinho , Magazine of Concrete Research, Volume 72, Number 7, p.339-356, (2020) AbstractWebsite

This paper describes the experimental campaign to study the behaviour of reinforced-concrete flat slab structures with steel stirrups as punching shear reinforcement, under combined vertical and horizontal cyclic loading. The vertical load was first applied and kept constant during the test, while, regarding the cyclic horizontal loading, imposed cyclic drifts were increased until failure. Four slab specimens with shear reinforcement were tested and the results compared to a control slab specimen without shear reinforcement. The studied variables were different shear reinforcement ratios and the number of stirrup layers. The slabs were 4·15 × 1·85 m2 and 0·15 m thick, connected to two steel half-columns. The test setup used was developed by the research team and aimed to simulate the boundary conditions of a flat slab, representing the slab between middle spans in one direction and between zero bending moment points in the other direction. Results show that the use of steel stirrups as shear reinforcement is very effective, increasing shear, drift and energy dissipation capacities. The obtained results were also compared to the provisions given by European and American codes.