Journal Article
Punching of reinforced concrete flat slabs – Rational use of high strength concrete, Inácio, Micael M. G., Lapi Massimo, and Ramos Antonio Pinho , Engineering Structures, Volume 206, p.110194, (2020) AbstractWebsite

This paper deals with punching of reinforced high strength concrete (HSC) flat slabs. Despite the use of HSC increased significantly in the last years, the experimental research on punching behavior of HSC slabs is still limited. Furthermore, most of this past research adopted concrete compressive strength lower than 90 MPa. In a previous work by this research group three specimens with concrete compressive strength around 120 MPa and one with normal strength concrete (NSC) were tested. The present work represents the continuation of the previous activity and it is focused on the rational use of HSC. Four specimens with HSC and one of NSC were tested under monotonic vertical loading. The HSC was placed only in the slab-column connection region and it was limited to a thin layer in the compressive zone, in order to have a more economical and sustainable solution. This rational use of the HSC showed excellent results in terms of punching strength. Limiting the HSC to a thin layer in the compressive zone resulted in an almost equal punching strength to that obtained with the slab entirely casted in HSC.

Rational use of HPFRC in slab – column connections under reversed horizontal cyclic loading, Ramos, António, Isufi Brisid, Marreiros Rui, Bolešová Mária, and Gajdošová Katarina , Engineering Structures, Volume 270, (2022) AbstractWebsite
n/a
Reforço de lajes fungiformes com armadura transversal pós-instalada usando diferentes técnicas de ancoragem, Inácio, Micael, Ramos António, and Faria Duarte , Revista Portuguesa de Engenharia de Estruturas, Volume III, Number 3, p.63–74, (2017) Abstract

n/a

Reversed horizontal cyclic loading tests of flat slab specimens with studs as shear reinforcement, Isufi, Brisid, Ramos António Pinho, and Lúcio Válter , Structural Concrete, (2018) AbstractWebsite

The results of a series of experiments on four reinforced concrete flat slab specimens with shear studs and a control specimen without any shear reinforcement are presented. The specimens were tested under constant gravity loads and reversed horizontal cyclic displacements. The main test variables were the applied gravity load and the number of perimeters of studs. One of the specimens was tested in two phases to study the postearthquake behavior. Results showed a considerable improvement of the deformation capacity of specimens with studs compared to the reference specimen. In agreement with previous research, increasing the applied gravity shear ratio resulted in a lower experimental drift capacity. It is shown that a better explanation of the observed ultimate drifts can be made by considering also the flexural capacity and the extent of shear reinforcement. The specimen tested in two phases exhibited considerable residual capacity, even after severe horizontal loading.

Reversed horizontal cyclic loading tests of flat slab specimens with studs as shear reinforcement, Isufi, Brisid, Ramos António Pinho, and Lúcio Válter , Structural Concrete, Volume 20, Number 1, p.330-347, (2019) AbstractWebsite

The results of a series of experiments on four reinforced concrete flat slab specimens with shear studs and a control specimen without any shear reinforcement are presented. The specimens were tested under constant gravity loads and reversed horizontal cyclic displacements. The main test variables were the applied gravity load and the number of perimeters of studs. One of the specimens was tested in two phases to study the postearthquake behavior. Results showed a considerable improvement of the deformation capacity of specimens with studs compared to the reference specimen. In agreement with previous research, increasing the applied gravity shear ratio resulted in a lower experimental drift capacity. It is shown that a better explanation of the observed ultimate drifts can be made by considering also the flexural capacity and the extent of shear reinforcement. The specimen tested in two phases exhibited considerable residual capacity, even after severe horizontal loading.

A review of tests on slab-column connections with advanced concrete materials, Isufi, Brisid, and Ramos António Pinho , Structures, Volume 32, p.849-860, (2021) AbstractWebsite

Advances in concrete technology during the last decades have resulted in the development of materials with enhanced mechanical properties, such as High Strength Concrete (HSC), Fibre Reinforced Concrete (FRC) and Ultra-High Performance Fibre Reinforced Concrete (UHPFRC). The application of these materials in flat slabs, which are a popular structural solution in Reinforced Concrete (RC) buildings worldwide, has the potential of significantly reducing raw material consumption by enabling the design of slenderer and therefore lighter structures. However, flat slabs are susceptible to punching shear failure, which is a complex phenomenon that remains challenging, even though significant efforts have been made to experimentally study it. For advanced concrete materials (HSC, FRC and UHPFRC), the challenge is further accentuated by the continuous and rapid development of these materials. With the purpose of identifying and highlighting gaps in the published literature, a review of tests with HSC, FRC and UHPFRC slab-column connections in non-seismic and seismic loading applications is presented in this paper. It is shown that future research directions in this field include, among others, testing thicker slabs, HSC slabs with higher concrete compressive strength, HSC combined with FRC and several more cases related to seismic loading conditions.

Role of punching shear reinforcement in the seismic performance of flat slab frames, Isufi, B., Cismasiu I., Marreiros R., Pinho Ramos A., and Lúcio V. , Engineering Structures, Volume 207, (2020) AbstractWebsite
n/a
Seismic Performance of Reinforced Concrete Buildings with Joist and Wide-Beam Floors during the 26 November 2019 Albania Earthquake, Baballëku, Markel, Isufi Brisid, and Ramos António Pinho , Buildings, Volume 13, Number 5, (2023) AbstractWebsite
n/a
Seismic Performance of Strengthened Slab-Column Connections in a Full-Scale Test, Ramos, António Pinho, Isufi Brisid, Marreiros Rui, Coronelli Dario, Netti Teresa, Lamperti Tornaghi Marco, Tsionis Georgios, and Muttoni Aurelio , Journal of Earthquake Engineering, Volume 27, Number 9, p.2299 – 2318, (2023) AbstractWebsite
n/a
Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Structural Concrete, Volume n/a, Number n/a, (2020) AbstractWebsite

Abstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.

Shear and flexural strengthening of deficient flat slabs with post-installed bolts and CFRP composites bonded through EBR and EBROG, Torabian, Ala, Isufi Brisid, Mostofinejad Davood, and Ramos António Pinho , Structural Concrete, Volume 22, Number 2, p.1147-1164, (2021) AbstractWebsite

Abstract Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure-deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post-installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.

Slab–column connection punching and ductility improvement methods for seismic response of buildings with flat slabs, Isufi, Brisid, Almeida André, Marreiros Rui, Ramos António Pinho, and Lúcio Válter , Structural Concrete, Volume 23, Number 3, p.1385 – 1398, (2022) AbstractWebsite
n/a
Strengthening of flat slabs with transverse reinforcement by introduction of steel bolts using different anchorage approaches, Inácio, Micael M. G., Pinho Ramos A., Faria Duarte M. V., and Lúcio Válter J. G. , Engineering Structures, nov, Volume 44, p.383–397, (2012) AbstractWebsite

This work presents an experimental study concerning the post-punching behaviour of flat slabs strengthened with a new technique based on post-tensioning with anchorages by bonding using an epoxy adhesive. This strengthening technique proved efficient with respect to ultimate and serviceability states. Five slab specimens were tested in the post-punching range and it was found that the post-punching resistance was on average 78{%} of the punching resistance. This paper reports the development of strand forces and slab displacements from the beginning of the tests, including the bond stresses developed at several stages of the loading process. It was observed that top reinforcement bars were capable of transmitting post-punching loads to the prestressing strands. Taking this into account and based on the load bath envisaged from the column to the slab, expressions for the vertical load capacities corresponding to the parts of the load path are presented and compared with the experimental results, showing their ability to predict both ultimate loads and modes of failure. Compared with other strengthening techniques, the one proposed here not only upgrades ultimate and serviceability behaviour but also adds post-punching resistance, which is a great advantage in the event of progressive collapse, since it may avoid the collapse of an entire structure, thus reducing the risk of material and human losses.

Magazine Article
Utilização de betão de elevada resistência em lajes fungiformes, Inácio, Micael, Almeida André, Lúcio Válter, and Ramos António , Revista Portuguesa de Engenharia de Estruturas, Volume III, Issue 5, p.27-36, (2017)